Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Foxboro DCS FCP280 Supported Devices

Supported Devices

The FCP280 supports the following devices on the 2 Mbps fieldbus:

– All compact and standard 200 series FBMs, which support many types of intelligent field devices.

including those on Foundation Fieldbus, PROFIBUS, HART, and DeviceNet networks.

– Foxboro DCS Field Device System Integrator (FDSI) Modules

– Intrinsically Safe I/O Subsystem (ISCM) – see Intrinsically Safe I/O Subsystem (PSS 31H-2Y6)

– DCS Migration Fieldbus Module for Siemens APACS+ Systems

– DCS Migration Fieldbus Module for Westinghouse WDPF® Systems

– DCS Fieldbus Migration Module for Fisher PROVOX® 20 Series Migration HART

– DCS Fieldbus Migration Module for Honeywell® TDC 2000 Systems 

(with standard backplane for HART use).

The FCP280 supports the following devices on a 268 Kbps fieldbus:

– 100 Series FBM

– SPECTRUM™ Migration Integrator

– SPEC 200™ Control Integrator

– SPEC 200 MICRO™ Control Integrator

– SPEC 200 CCM Control Integrator

Foxboro Gas Chromatographs are not supported.

A-B 1336 PLUS II Adjustable Frequency AC Drive Special Functions

Special Functions

– Auto economiser

– Process PI controller

– Traverse function

– Optional Fault

Reset and run

– Automatic restart on switch-on

– Speed-sensitive electronics

Overload

– Auto-adjustment

– Step Logic

Operation

– Controls

– Selectable Volt/Hertz mode

– Multi-language selection

Programmable

– Dual acceleration/deceleration curves

– Three frequency jumps

– DC injection braking

– Dynamic braking

– Slip compensation

– Negative sliding compensation

Sag

– S-curve acceleration/deceleration curve

– Line Loss Restart Mode

– Active Current Limit

– Last four event fault memory

– Flight Start

– Seven preset speeds

Input/Output Interface

– Control Output Contacts

(2) Form A (N.O.)

(2) Form C (N.O. – N.C.)

Programmable to 17 different drive variables.

– Flexible analogue

Inputs/Outputs

– Pulse train input

– Encoder feedback Closed loop

– High-speed inputs

A-B 1336 PLUS II Adjustable Frequency AC Drive

Start-up operation

For applications requiring unattended operation, the 1336 PLUS II can resume operation when power is

restored after a power failure.

If the Power On Run feature is activated and the input power supply is disconnected, then when the

power is restored

The drive will automatically restart and run at the current commanded speed if all the necessary signals 

(Enable, Auxiliary, No Stop and Start) are present.

4-20mA Current Loss Option

Many control systems will issue a 4-20mA control signal for the drive to use as a speed reference.

The drive will run at the lowest speed with the 4mA signal and at the highest speed with the 20mA signal.

The drive can also invert this signal to run the minimum speed at 20mA and the maximum speed at 4mA.

Since a minimum signal of 4mA is required, the drive must have a ‘fallback’ command

in the event of signal loss (sensor failure or disconnection).

The 1336 PLUS II includes a ‘Loss Selection’ parameter that provides five choices for signal failure modes.

1. stop the drive and signal a fault.

2. Go to minimum speed and issue a warning.

3. Go to maximum speed and issue a warning.

4. Maintain speed and issue a warning.

5. reaches preset speed and warns.

Related Product Recommendations:

1336-SN-SP1A

1336-SN-SP1B

1336-SN-SP21A

1336-QOUT-SP5A

1336-QOUT-SP6A

1336-QOUT-SP8A

1336-QOUT-SP12B

1336-QoUT-SP13A

1336-QOUT-SP14A    

1336-QOUT-SP18A

1336-FEET-SP8A

1336-FEET-SP5A

1336-FEET-SP6A

1336-MOv-SP1A

1336-Mov-sP3A

1336-R2-SP2A

1336-R2-SP1A

1336-RLOAD-SP2A

1336-RLOAD-SP3A

1336-RLOAD-SP4A

1336-RLOAD-SP5B

1336-STDOFF-SP1A

1336-SCREW-sP3A

1336-BDBMX3-SP60A

1336-BDBMX3-SP24A

A-B 1336 PLUS II Traverse Function

Function Description

Traverse Function

The 1336 PLUS II output frequency can be programmed to modulate around a set frequency.

This can be achieved by setting three parameters to create an inertia compensated delta waveform

– Traverse Period, Maximum Traverse, and P Jump. In surface drive winding applications,

the developed waveforms can be used in a traverse drive to electronically perform the traverse function.

The traverse actuator will move the yarn back and forth in a diamond pattern so that

the yarn is evenly distributed over the surface of the tube.

This pattern must be changed in order to prevent yarn build-up at the same points on the surface.

This can be achieved by constantly continuously changing the traverse speed in a cyclic

manner over a specified speed range. Using inertia compensation, a series of distributed diamond 

patterns can be formed over the entire surface of the tube.

Bently Nevada ORBIT 60 SERIES External Display System Display Brightness

Display Brightness

The brightness of an LCD display is the amount

of light emitted and is measured in nits or

candelas per square meter, which has units of

nits or cd/m2. Most commercial desktop

displays have a brightness of 200 to 300 nits. To

see a display in outdoor light requires a

brightness of about 700 nits or greater. Almost

all new LCD displays use some form of white or

RGB LED backlight.

Some of the brighter displays can have

a half-life of 20.000 hours or less.

Bright Idea: The brightness life of the display

can be dramaticallyincreased and burn-in can

be mitigated by allowing the screen saver to

dim and/or turn off the display when not in use.

Bently Nevada Display Brightness Half-Life

Display Brightness Half-Life

An important characteristic of an LED backlight

is the brightness half-life, which is the time

measured in hours that the brightness output

will decrease by half after running the LED

backlight at full brightness. The decrease in

brightness will not substantially decrease after

the half-life time has elapsed. Most displays

have a half-life of around 50.000 hours (or 5.7

years). Some of the brighter displays can have

a half-life of 20.000 hours or less.

Bright Idea: The brightness life of the display

can be dramaticallyincreased and burn-in can

be mitigated by allowing the screen saver to

dim and/or turn off the display when not in use.

Bently Nevada ORBIT 60 SERIES External Display System Orbit Display

Touchscreen Display Support

Orbit Display uses a touchscreen display. You

can show data from up to twelve Orbit 60

chassis connected via Ethernet on a single

Orbit Display.

If necessary, Bently Nevada can produce

custom drivers for specific displays and

pointing devices. For assistance, or for a list of

supported displays and required drivers,

contact Bently Support at Bently.com/support.

The Orbit Display is backwards compatible  with

the existing 10.4″ and 15″ displays currently

supported by the 3500 system:

Supported Displays

120M8155-01  10.4” 640×480 Hazardous Location Display

102M8950 15” 1024×768 Hazardous Location Display

150M1466  21.5” 1920×1080 Industrial Display

Display Burn-in or Ghosting

All display technologies are susceptible to

burn-in or ghosting, which occurs when static

and cumulative non-uniform pixel use

discolors areas on a screen. Burn-in can be

noticed when the display changes and when

the display is turned off.

Bently Nevada ORBIT 60 SERIES External Display System

Display Placement

Expensive KVM Extenders are not needed to place displays far

away from Orbit 60  installation locations. Since the Orbit

Display connects to Orbit 60 chassis via standard Ethernet

network connections, the Orbit 60 Display system can be

placed anywhere your Ethernet network infrastructure

supports. The display location is only limited by security and

network infrastructure necessary to support Orbit Display.

It is possible to place Orbit Display in a variety of locations:

• Physically adjacent to Orbit 60 chassis

• Next to the machines being monitored

• In a local or remote control room

The Orbit Display system includes your choice of display

screen, an industrial computer with a customized operating

system, and software that communicates with one or more

Orbit 60 systems. The system can be certified for hazardous

locations. Condition monitoring data is communicated to

external displays via a Display Port or VGA connection.

Bently Nevada ORBIT 60 SERIES Orbit Display

Orbit Display

The Orbit Display system includes your choice of display

screen, an industrial computer with a customized operating

system, and software that communicates with one or more

Orbit 60 systems. The system can be certified for hazardous

locations. Condition monitoring data is communicated to

external displays via a Display Port or VGA connection.

Touchscreen connection can use USB or Serial connection.

The Orbit Display shows Orbit 60 machinery protection

system information such as:

• Direct measurements

• 1X measurements

• Gap measurements

• Measurement alarms

• System event list

• Alarm event list

The standard tabs show direct measurements, 1x filtered

vibration measurements, gap values, and other trended

variables.

Bently ORBIT 60 SERIES Electromechanical Relay (EMR)

Electromechanical Relay (EMR)

This relay drives a load directly, or through, an interposing

relay. This module takes two slots. It features 8 Epoxy Sealed,

Single-Pole Double-Throw Electromechanical Relays. This

module supports an AC voltage range of 5-250 Vac for loads

of 100 mA to 4 A. The module also supports DC voltages and

loads of 5-30 Vdc at 4 A.

Solid State Relay (SSR)

This relay connects to an external system’s discrete input for

low current communication. It occupies a single slot and

features 8 Solid-State Relays. This module supports

secondary voltages from 1 Vdc up to 125 Vdc

and loads of 0.01 to 125 mA.

Search for products

Back to Top
Product has been added to your cart