Emerson Network Power MVME5500 series

The MVME5500 utilizes the MPC7457 processor running at 1 GHz, which is ideal for

data intensive applications. The MVME5500 provides more than just better processor

performance; it also provides balanced performance from the processor, memory,

dual independent local buses and I/O subsystems.

The powerful Marvell system controller, with support for a 133 MHz host bus and

a 133 MHz SDRAM memory bus, is well matched to the high speed processor. To

match the system I/O to the outstanding processor performance, the MVME5500

provides dual 64-bit, 33/66 MHz PCI buses. Each PCI bus has a PMC site supporting

cards running at 33 or 66 MHz. The Universe II VME interface and PMCspan connec

tor are isolated from the PMC sites on a dedicated 33 MHz PCI bus segment so that

both PMC sites are capable of 66 MHz operation.

The MVME5500 also offers a Gigabit Ethernet interface, a 10/100BaseTX Ethernet

interface and two serial ports. All of this adds up to a set of well-balanced,

high-performance subsystems for unparalleled performance.

Emerson The MVME5500 is the flagship of our VME product line

The MVME5500 is the flagship of our VME product line that enables

higher levels of performance in a single VMEbus slot

• MPC7457 PowerPC ® processor at 1 GHz

• 512KB of on-chip L2 cache and 2MB of L3 cache

• AltiVec coprocessor for high performance computational applications

• Two banks of soldered flash memory (32MB and 8MB)

•  Dual independent 64-bit PCI buses and PMC sites with a bus speed of up to 66 MHz

•  Gigabit Ethernet interface plus an additional 10/100BaseTX Ethernet interface

•  64-bit PCI expansion mezzanine connector allowing up to four more PMCs

•  I/O compatibility with MVME51xx family

•  Support for processor PMCs (PrPMCs)

The Emerson Network Power MVME5500 series is designed to meet the needs of

OEMs including those in defense and aerospace, industrial automation and medical

imaging market segments. Customers looking for a technology refresh for their

application while maintaining backward compatibility with their existing VMEbus

infrastructure can upgrade to the MVME5500 series and take advantage of the

enhanced performance features.

Emerson Control Configuration Transition Services

Control Configuration Transition Services

Display Transition Services

System Compatibility

The S-Series PROVOX I/O Carrier is not compatible with the

DeltaV VIM, VIM2. Zone 2 Remote I/O card, SLS 1508. the

Smart Wireless Gateway and the WIOC.

The S-Series PROVOX I/O Carrier can also communicate to

DeltaV CIOC & CHARMs for easy in-situ migration from the

PROVOX termination panels directly to DeltaV CHARMs

Electronic Marshalling I/O.

The S-Series PROVOX I/O Carrier is not compatible with DeltaV

M-Series I/O Products.

Asset Management Solutions. AMS uses the process control

network, while DeltaV controllers and the PROVOX I/O Interface

provide communications access to smart field devices.

This provides a seamless solution to manage your plant assets.

Maximize your display engineering efficiency.  Emerson

offers services for generating your new DeltaV displays. Learn

how PROVOX configuration can be automatically converted or

how new display and control designs can optimize effectiveness

of your new DeltaV Controller Interface for PROVOX.

Emerson The DeltaV Controller Interface for PROVOX I/O control

Complete Integration. The DeltaV Controller Interface for

PROVOX I/O control solution is fully supported by DeltaV

Explorer, Control Studio, and Diagnostic applications. You can

configure and integrate PROVOX I/O as easily as DeltaV I/O.

DeltaV Explorer fully supports configuration, commissioning

and assignment of PROVOX I/O (Control I/O and MUX I/O)

cards. You can auto-sense Control I/O cards, and use DeltaV

Explorer to enable and configure all I/O channels.

The DeltaV Diagnostic application supports all PROVOX I/O

diagnostic messages. You can easily and thoroughly monitor

I/O integrity.

HART® Data Availability. The DeltaV Controller Interface for

PROVOX I/O solution can read smart information from field

devices connected to PROVOX HART® input and output cards.

All of the HART information available in your PROVOX controller

is maintained in the DeltaV SQ or SX controller.

The interface can pass HART information to a DeltaV application

station, enabling you to use applications such as Asset

Management Solutions (AMS) to manage the field devices.

Asset Management Solutions. AMS uses the process control

network, while DeltaV controllers and the PROVOX I/O Interface

provide communications access to smart field devices.

This provides a seamless solution to manage your plant assets.

Emerson S-Series PROVOX I/O Interface Module

PROVOX I/O Interface Module. The PROVOX I/O Controller

Interface supports redundant Control I/O communications and

connections to Control I/O and Distributed I/O. Distributed I/O

is MUX I/O connected to the controller through the CP6601

serial buffer card.

Controller Carrier. DeltaV controllers mount on a 19 inch rack

specifically designed to accommodate:

• Two DeltaV SQ or SX controllers (one in a simplex installation)

• Two PROVOX I/O Interface modules (one in a simplex installation)

• Two DeltaV system power supplies (one in a simplex installation)

Railbus Connection. The PROVOX I/O Interface Carrier 25 pin

redundant VerticalPLUS railbus connections may be used to

interface with additional DeltaV S-Series I/O modules.

Standard VerticalPLUS DeltaV interface cables are used to

connect the PROVOX I/O Controller Interface Carrier to

traditional DeltaV I/O horizontal carriers. This feature let you

easily expand your system with DeltaV I/O to fully utilize your

DeltaV controller investment.

DeltaV Programmable Serial Cards can connect PLCs and other

serial devices formerly connected to PROVOX IDIs or EICs (non

weigh scale interface option on the EIC).

Emerson S-Series DeltaV™ Controller Interface

Product Description

The DeltaV Controller Interface for PROVOX I/O consists of a

19-inch rack mountable controller carrier, simplex or redundant

DeltaV SQ or SX controllers with power supplies, and a PROVOX

I/O Interface for each controller.

DeltaV SQ  or SX Controller. Mount one DeltaV SQ or SX

controller on the carrier for a simplex installation. Mount

two SQ or SX controllers for a redundant installation. and SQ

controllers can handle up to 750 DSTs, while SX controllers can

handle up 1500 DSTs.

PROVOX I/O Interface Module. The PROVOX I/O Controller

Interface supports redundant Control I/O communications and

connections to Control I/O and Distributed I/O. Distributed I/O

is MUX I/O connected to the controller through the CP6601

serial buffer card.

Controller Carrier. DeltaV controllers mount on a 19 inch rack

specifically designed to accommodate:

• Two DeltaV SQ or SX controllers (one in a simplex installation)

• Two PROVOX I/O Interface modules (one in a simplex installation)

• Two DeltaV system power supplies (one in a simplex installation)

Emerson S-Series Benefits-Maximizes investment in PROVOX I/O

Benefits

Provides an easy upgrade for PROVOX IFC, UOC, SR90 and

SRx Controllers. You can easily upgrade your UOC, IFC, 20

Series, SR90 or SRx controller to a DeltaV controller, and

continue to use PROVOX I/O by connecting it to the DeltaV

controller carrier.

Maximizes investment in PROVOX I/O. Using your PROVOX

I/O with a DeltaV controller maximizes your investment in

PROVOX I/O, extending its useful life andsaving the cost of

new I/O.

Saves wiring costs. The DeltaV Controller Interface for

PROVOX I/O enables you to greatly reduce wiring costs and

shorten turnaround time, because you don’t have to re-wire

field devices to new I/O.

Redundancy in controllers. Two DeltaV controllers and

power supplies can be mounted on the carrier for full

controller redundancy.

Redundancy in Control I/O connections. The DeltaV

Controller for PROVOX I/O carrier provides for redundant

connections to Control and Distributed I/O files.

Retains I/O redundancy in Control I/O. The DeltaV Controller

Interface for PROVOX I/O allows use of flexible redundancy

arrangements possible with Control I/O, including 1:1 and 1:N

card redundancy.

Emerson S-Series DeltaV™ Controller Interface for PROVOX™ I/O Introduction

• I Provides a fast and easy upgrade for PROVOX™

• IFC, UOC, 20 Series, SR90. and SRx Controllers

• Maximizes investment in PROVOX I/O

• Saves wiring costs—no rewiring!

• Redundancy in controllers

• Redundancy in Control I/O connections

• Retains the I/O redundancy in Control I/O

Introduction

Emerson Process Management continues its long-standing

excellence in providing solid control solutions with the S-Series

DeltaV™ Controller Interface for PROVOX I/O and DeltaV SQ

or SX Controllers. You can transition to DeltaV controllers

and connect to PROVOX I/O already installed in your plant,

continuing to maximize your original PROVOX I/O investment.

The DeltaV Controller Interface for PROVOX I/O can be used

with both Control I/O and Distributed (MUX) I/O, which

connects using the serial buffer card. The interface to PROVOX

I/O uses an SQ or SX controller and a DeltaV power supply

installed on the PROVOX I/O Carrier.

With this solution, PROVOX I/O support is integrated into

standard DeltaV engineering and diagnostics, including DeltaV

Explorer and Control Studio.

Emerson The DeltaV S-series Serial Card can support other serial driver

Other Protocols Supported

The DeltaV S-series Serial Card can support other serial

driver protocols downloaded directly into the serial card.

Custom drivers available from Emerson for the DeltaV serial

card include:

• Allen-Bradley Data Highway Plus

• Mettler Weight Scale

• Redundant Enhanced Modbus

• Sartorius Weight Scale

Call your local sales office for availability of custom drivers.

An alarm on the integrity error for the primary card notifies

the operator of a switchover. The backup card is also

monitored for integrity alarms.

The system automatically commissions and downloads a

replacement standby card. In safe areas, failed cards can

be replaced under power. In hazardous areas, appropriate

installation procedures must be followed.

Emerson S-series The redundant pair can be manually configured or Autosensed

The redundant pair can be manually configured or

Autosensed. The redundant terminal block couples the

two cards as one redundant pair that when Autosensed,

the DeltaV system automatically recognizes the redundant

pair of cards and assigns a device signal tag (DST) to the

datasets on the primary card (Odd numbered card).

Switchover time for redundant I/O is minimal, and the

process will be undisturbed. Output channel behavior

on switch over can be configured to resend outputs on a

switchover. This can be coupled with Output Read back to

ensure the output channels are driven to the desired state

upon switchover.

An alarm on the integrity error for the primary card notifies

the operator of a switchover. The backup card is also

monitored for integrity alarms.

The system automatically commissions and downloads a

replacement standby card. In safe areas, failed cards can

be replaced under power. In hazardous areas, appropriate

installation procedures must be followed.