Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Autronica POWER CABINET BP-405

Description/Application

The Power Cabinet BP-405 provides space for two

12V/18Ah batteries (not included).

The maximum power available is 24V/5A.

NOTE:

Do not connect batteries in parallel in an attempt to

obtain higher ampere hour (Ah) capacity.

If additional power is required in an installation, an

additional cabinet BP-405 with 24V/5A power supply

can be used.

The power supply and battery brackets are already

mounted when the cabinet is delivered from the

factory.

Dipswitch Settings

Dipswitch settings for dipswitch S6 on Power Board

BSF-400.

Autronica BP-405 Features

Features

 Power Cabinet containing 5A/24V power supply

and Power Board BSF-400 with 2x12V, 18Ah

batteries (batteries not included)

 Power Board BSF-400. including

 AutroFieldBus interface

 115VAC /230VAC input

 6 outputs 24VDC (max. 2A each)

 1 fault relay output

 Available space for 2x12V, 18Ah batteries

 Conforms to CE standards

 Designed to meet IEC 61508 SIL2 requirements,

CEN, EN 54-2. EN 54-4 and EN 54-13

regulations, FM regulations (Factory Mutual) and

the maritime SOLAS requirements (Safety Of

Life At Sea)

Autronica Fireman panel microphone kit

The Fireman Panel Microphone kit consists of an AutroSafe Fire Brigade

Panel BU-BV-420 and a miniVES/MULTIVES Fireman Microphone with zone

buttons in the same housing.

The AutroSafe Fire Brigade Panel is placed in the upper section of the kit. It is intended to provide information

related to fire alarms in the relevant Operation Zone and allow the fire brigade to operate fire alarms.

The panel displays alarms and allows you to operate alarms and receive additional information related to the

relevant operation zone. To operate alarms, a fireman’s key must be used (access level 2).

The panel is used to silence sounders and to reset alarms within a defined operation zone.

The panel provides the following buttons:

 More Events button

 Mute Panel button

 Silence Alarms button

 Reset System button

The panels provides the following indicators:

 Fire, More Events, Fire Brig. Signalled, Fault, Function Disabled, Testing, System Fault, Power

 Internal buzzer

For more detailed information about the Fire Brigade Panel, see separate datasheet (116-P-BU-BV-420/CGB).

Autronica Fire brigade loop panel BU-110

Description / Application

The unit has been designed for use with AutroSafe 4

Interactive Fire Detection System.

From the Fire Brigade Loop Panel BU-110 it is possible to

mute the panel’s internal buzzer, silence/resound

sounders/bells etc. and reset the system.

The panel can be configured (by means of the

configuration tool) to show detection zones and point

information in an alarm situation, or detection zones

only.

Only points in alarm are shown in the display. Faults and

disablements are indicated by LED indicators. The total

number of detection zones in alarm will always be

shown.

By operating the More Events Button, it is possible to

scroll through and view detailed information of the first

64 alarms (or 32 first alarms, if the panel is configured to

show both detection zones and points).

The panel is powered by the detection loop.

Autronica BU-110 Operator controls

Operator controls

The panel offers the following buttons:

• More Events button for scrolling through several

alarms

• Silence Buzzer (60 dB) for silencing the internal buzzer

(access level 1). The internal buzzer will remain muted

until a new alarm is triggered

• Silence Alarm button

• Combined Reset button/Lamp Test (access level 1)

• Contrast settings: to start the contrast settings

(access level 1), press and hold the Silence Buzzer

button for 5 seconds until audible beep, observe

changes, then release the button to confirm the new

contrast (a new audible beep is heard)

Autronica BU-110 Features

Features

• User-friendly display and operator controls

• Scroll function for more alarms

• Text display suitable for full darkness operation

• On-wall mounting

• Conforms to EN 54 regulations

• Conforms to CE standards

• Designed to meet the requirement of the major

maritime classification societies

Indicators

The panel provides the following indicators:

• Fire symbol, Alarm Routing Activated, Fault, Function

Disabled, Test, System Fault, Power, More Events

• Internal buzzer

Capacity

A maximum of 8 panels can be connected to the

detection loop.

Compatibility – AutroGuard Protectors

When using AutroGuard protectors, note that

BU-110 firmware 1.6 or newer is required.

Autronica BV-110 Operator controls

Operator controls

The panel offers the following buttons:

• More Events button for scrolling through several

alarms within the same event window

• Silence Buzzer (60 dB) for silencing the internal

buzzer. The internal buzzer will remain muted

until a new alarm or fault is triggered

• Next Window button for stepping to a new event

window, for example from Fire Alarm to Fault

Warning window

• Contrast settings: to start the contrast settings

(access level 1), press and hold the Silence

Buzzer button for 5 seconds until audible beep,

observe changes, then release the button to

confirm the new contrast (a new audible beep is

heard)

• Lamp Test button for activating all indicators

Indicators

The panel provides the following indicators:

• Fire Symbol, Alarm Routing Activated, Fault,

Function Disabled, Test, System Fault, Power,

More Events

• Internal buzzer

Autronica Information loop panel BV-110

Description / Application

The unit has been designed for use with AutroSafe 4

Interactive Fire Detection System.

The Information Loop Panel BV-110 serves as an

indication device only. It provides information

related to the defined operation zone(s).

The panel can be configured (by means of the

configuration tool) to show detection zones and point

information in an alarm situation, or detection zones

only.

By operating the More Events Button, it is possible to

scroll through and view detailed information of the first

64 alarms (or 32 first alarms, if the panel is configured to

show both detection zones and points).

The panel can store up to 6 faults and 6

disablements. The total number of faults and

disablements in the system will always be shown,

but it is only possible to scroll through and view

detailed information of the first 6 faults and

disablements (using the More Events Button).

Compatibility – AutroGuard Protectors

When using AutroGuard protectors, note that

BV-110 firmware 1.6 or newer is required.

Autronica BV-110 Features

Features

• User-friendly display and operator controls

• Scroll function for more alarms

• Text display suitable for full darkness operation

• Displays alarms, faults and disablements

• Possible to change to different event windows

• On-wall mounting

• Conforms to EN 54 regulations

• Conforms to CE standards

• Designed to meet the requirement of the major

maritime classification societies

Indicators

The panel provides the following indicators:

• Fire Symbol, Alarm Routing Activated, Fault,

Function Disabled, Test, System Fault, Power,

More Events

• Internal buzzer

Capacity

A maximum of 8 panels can be connected to the

detection loop.

Autronica BU-BV-420 Information Panel

Information Panel

The Information Panel serves as an indication device

only. It provides information related to the defined

operation zone(s).

The panel offers the following buttons:

• More Events button for scrolling through several

alarms within the same event window

• Next Window button for stepping to a new event

window, for example from Fire to Fault Warning

window.

• Lamp Test button for activating all indicators to be lit

for 5 seconds

The panels provides the following indicators:

• Fire / Alarm, Function Disabled, Function Delayed,

Testing, Power

• Internal buzzer

Search for products

Back to Top
Product has been added to your cart