IC695CRU320-EZ PACSystems RX3i Redundancy CPU Features

RX3i System Manual, GFK-2314F or later. 

▪ Supports up to 512 program blocks. Maximum size for a block is 128KB. 

▪ CPU firmware may be upgraded in the field. 

▪ CPU supports firmware upgrades of modules in its backplane. 

▪ Two serial ports: an RS-485 serial port and an RS-232 serial port. 

▪ Ethernet communications via the rack-based Ethernet 

Interface module (IC695ETM001). For details on Ethernet 

capabilities, refer to PACSystems RX7i & RX3i TCP/IP 

Ethernet Communications User Manual, GFK-2224. 

▪ Time Synchronization to SNTP Time Server on Ethernet 

network when used with Ethernet Release 5.0 or later. 

▪ Compliant with EU RoHS Directive 2002/95/EC using the 

following exemptions identified in the Annex: 7(a), 7(c)-I, & 7(c)-III.

IC697PCM711 Programmable Coprocessor Module Installation

Installation

• Installation should not be attempted without refer

ring to the applicable Programmable Controller

Installation Manual (see reference 5).

• Make sure rack power is off.

• Install expansion memory if required.

• Connect the battery to either of the battery con

nectors on the module. (See figure 2)

• Install in the rack. (See figure 1)

• Turn on power.

The module should power up and blink the top LED.

When the diagnostics have completed successfully the

top LED stays on.

Expansion Memory

The PCM can operate with or without an expansion

memory daughter board.  The base memory on the

PCM board has up to 95 Kbytes user memory.  The ex

pansion memory daughter board permits expansion of

program/data memory by 64. 128. 256 or 512 Kbytes.

The battery which supports this memory is located on

the base board housing as shown in figure 2.

IC697MEM713 CMOS Expansion Memory Batteries

Batteries

The Lithium battery (IC697ACC701) is installed as

shown in figure 1.  This battery maintains user

memory when power is removed and operates the

calendar clock on the PLC CPU.  Be sure to install the

new battery before removing the old battery.  Specific

indication of a low battery state is detailed in References 3 and 4.

Turn power on.

CPU Installation:

Clear memory using either MS-DOS or

Windows programming software following

instructions in the Programming Software User’s

Manual (See reference 1).

PCM Installation:IC697MEM713 CMOS Expansion Memory Installation

For the PCM follow the instructions in the Pro

grammable Coprocessor Module Support Software

User’s Manual (See reference 3).

IC697MEM713 CMOS Expansion Memory Installation

Installation

Installation should not be attempted without refer

ring to the applicable Programmable Controller

Installation Manual (See reference 4).

Make sure rack power is off.

Plug the 64 pin connector into the connector on

the base board, and engage snaps.

Place module in rack.

Turn power on.

CPU Installation:

Clear memory using either MS-DOS or

Windows programming software following

instructions in the Programming Software User’s

Manual (See reference 1).

PCM Installation:

For the PCM follow the instructions in the Pro

grammable Coprocessor Module Support Software

User’s Manual (See reference 3).

FOXBORO 130M Series Pnuematic Controller Easy Maintenance

Easy Maintenance

The 130 Series utilizes a unique pneumatic circuit board that greatly enhances the sophistication of the pneumatic control system.

This board eliminates many of the piping and connections found in other controllers.

All components are located on one side of the board and are easily accessible by sliding back the cover on one side.

Force Balance Control Module

The proven force balance control module ensures long service life and reliability.

Due to the use of metal bellows, there is virtually no movement in the flexure suspension mechanism, thus providing the user with a clearly superior controller.

Specialized Controllers for Every Application

Foxboro offers the industry’s widest range of optional accessories and specialized control features.

In addition to normal control modes, these include single-station ratios, single-station computer setups, auto selectors, differential gaps, and “batch” processing.

FOXBORO 130M Series Pnuematic Controller Separate automatic

Separate automatic and manual control units

Both the automatic and manual control units can be disassembled without disrupting the process.

This design feature avoids costly downtime for servicing the controller.

Completely Unbalanced and Bufferless Transmission

The 130 Series controllers utilize the “integral balancing” method for bufferless transfer.

After transfer, the controller simply responds at the integral (reset) rate that

This eliminates any error between setpoint and measurement.

In addition to providing easy, unbalanced and unbuffered transmission, this solution preserves the setpoint.

Simple and cost-effective installation

Up to 10 instruments can be accommodated in a multi-unit rack. All air connections are made when the controller is installed in the rack.

Piping costs are minimized as each rack has its own integrated air supply header and individual air shutoff valve.

Prosoft MVI69-PDPS PROFIBUS DP Slave Communication Module Specifications

General Specifications

– Single slot – 1769 backplane compatible

– Module is treated as an input/output module with access to processor memory for data transfer between the processor and the module

– Ladder logic is used to transfer data between the module and the processor. A ladder example file is included.

– Obtains configuration data from a configuration text file downloaded to the module. Sample configuration file included.

– Supports CompactLogix and MicroLogix 1500 LRP controllers except 1769-L23E-QBFC1B, 1769-L16x, and 1769-L18x.

Functional Specifications

PROFIBUS slaves have access to the input and output images of the device with up to 122 words of input and output data and up to 200 words in total.

– All standard baud rates up to 12 Mbps are supported.

– Configuration data is stored in the non-volatile memory of the MVI69 module

– Supports extended diagnostic data (DPV0)

– Automatic baud rate detection at all valid PROFIBUS V0 baud rates

– Multiple modules in one rack

Other Products

ProSoft Technology offers a full range of hardware and software solutions for a variety of industrial communication platforms.

Honeywell FC-SCNT01 51454926-176 Safety Controller Module Main Functions

Main Functions:

Input Functions: The FC-SCNT01 module is capable of receiving input signals from field devices, 

such as fire alarm signals from smoke detectors, door and window opening and closing status, etc. 

The input signals are processed and then processed by the FC-SCNT01 module.

These input signals are processed and sent to the main controller of the security system.

Output Function: The module is able to receive output commands from

the main controller and convert these commands into appropriate control signals to control the field devices.

For example, when the controller receives a fire alarm signal, it can send commands through

the FC-SCNT01 module to cause door locks to open automatically or to activate an evacuation alarm.

Communication Interface: FC-SCNT01 modules usually use standard communication protocols 

to communicate with the host controller to ensure reliable data transmission in the system.

Power supply and power isolation: Modules are usually equipped with power isolation to

ensure that no damage is caused to the system in case of power failure or abnormal conditions.

Status Indicators: Modules may be equipped with status indicators to indicate the status 

of input/output signals, power supply status, and possible fault status.

Overall, the Honeywell FC-SCNT01 51454926-176 is a powerful input/output module that is

capable of receiving and processing input signals from field devices and controlling

field devices according to the commands of the main controller, and is an integral part of the safety system.

Honeywell Digital Input Relay 5K Adapter FC-UIR501

Function

FC-UIR501 is a SIL 1 single channel relay isolated input module with a 5KOhm shunt resistor for low voltage applications. 

The relay coil of the adaptor interfaces with the field and the contact side gets connected to Safety system.

This module is powered by the field.

Features

• Single channel Digital Input Relay with 5KOhm shunt 

• Interface with Universal Safe Input Output Module