Emerson DeltaV S-series Traditional I/O Cards

I/O Cards

A variety of analog and discrete I/O interfaces are available to

meet your specific requirements. The following cards support

simplex or redundant installation:

• AI 4-20 mA HART, eight channels

• AO 4-20 mA HART, eight channels

• DI Dry Contact, eight channels

• DO 24V DC High Side, 8channels

• AI (Plus) 4-20 mA HART, 16channels

• AO (Plus) 4-20 mA HART, 16channels

• DI (Plus) 24V DC, Dry Contact, 32channels

• DO (Plus) 24V DC, High-Side, 32channels

The following I/O cards are supported in simplex format to

meet your field wiring needs.

• AI Isolated, four channels

• RTD, eight channels

• Thermocouple, eight channels

• Millivolt, eight channels

• DI 24V DC Isolated, eight channels

• Pulse Count Input, four channels (Isolated DI)

• Sequence of Event, 16 channels (DI 24V DC)

• DI 120V AC Low Side Detection, eight channels

• DI 120V AC Isolated, eight channels

• DO 24V DC Isolated, eight channels

Pulse Counters are available on most DI cards. The supported

maximum frequency varies from 0.1 Hz on AC signals to 75 or

120 Hz on 24V DC inputs, and up to 50 KHz on the High-speed Pulse input card.

Emerson DeltaV S-series Traditional I/O

1:1 Redundancy for traditional I/O cards: Increased

system availability is easy with S-series traditional I/O cards.

Four traditional I/O card types are available with redundant

terminal blocks for critical field circuits. Simply install a pair

of cards on the prescribed redundant terminal block and the

DeltaV Distributed Control System (DCS) will automatically

recognize them as a redundant pair. There is no configuration

other than to autosense the redundant pair.

Plug-and-play I/O: All S-series traditional I/O components

plug into the I/O interface carrier and are auto sensed by

the controller. There are no addressing switches or jumpers.

Cards can be installed in any order simplifying the I/O

subsystem design. New I/O interfaces are detected by the

system and added to the engineering database automatically.

Additional features can be enabled as needed and downloaded

without disruption to existing I/O communication,

allowing you to install the I/O you need today with the ability to expand tomorrow.

Emerson DeltaV S-series Traditional I/O Easy online expansion

Easy online expansion: The S-series I/O carriers and interfaces

can easily be added online, without disruption of existing

I/O communication. I/O carriers can be extended online,

either by directly connecting them to the right side of the

existing carrier, or using extender cables to mount the new

carrier on a different DIN rail. The controller automatically

detects new carriers and interfaces and allows these to be

auto-sensed into the configuration database.

Field-mounted capable hardware: All S-series traditional I/O

interfaces are rated for extreme operating temperature ranges

of -40 to 70°C (-40 to 158°F). The interfaces can be installed

in field mounted enclosures so you significantly reduce the

footprint of your equipment and increase valuable control room

space for other uses. This also allows you to save on wiring

expenses by eliminating the need for long runs of multi-cores.

The integrated design of the I/O subsystem can eliminate the

need for marshaling panels. This saves you even more in your

total capital costs.

Emerson DeltaV S-series Traditional I/O Reduced installation time and expense

Reduced installation time and expense: The DeltaV system’s

S-series I/O interfaces are designed for quick assembly and

error proof maintenance. All carriers snap onto T-DIN rails and

interfaces snap into the I/O slots without the use of any tools.

Each I/O interface has a separate wiring terminal block,

which connects field wiring to the interface. The I/O card can

easily be removed without touching the I/O wiring on the

terminal block. Some I/O cards can also use the fused terminal

block, which is equipped with in-line fuses that can be pulled

to isolate power to the field circuit.

Traditional I/O interfaces have I/O function keys that allow

the terminal block to be set to receive a specific I/O card.

These keys ensure that the correct I/O card is always plugged

into the corresponding terminal block. The keys provide a

safety measure by preventing the wrong I/O card being

installed. It’s incredibly easy to use and gives you time to do more.

The I/O carriers provide integrated bussed field power

distribution to the I/O interfaces.

Emerson DeltaV S-series Traditional I/O Benefits

Benefits

Modular and flexible construction: The S-series traditional

I/O subsystem is designed with your investment in mind.

Each controller supports up to eight I/O carriers that form a

robust, passive bus for up to 64 I/O interfaces. Each interface

has a matching I/O terminal block and can be installed in any

I/O slot on the bus. Carriers and interfaces can be added online,

without interruption to the existing I/O communication.

This modular design enables you to purchase the exact

amount of I/O cards, eight-wide carriers, power/controllers,

and two-wide carriers you need and add more DeltaV I/O

as your system grows.

The integrated bus is divided

into primary and secondary power for odd- and even-numbered

slots. Each slot is individually fused to protect power to other

cards. This significantly reduces the external power distribution

circuits while still providing each card with fused 24V DC bussed

field power.

ABB SYMAP Digital Protection Relays Data recorder

Data recorder (optional)

The data recorder can log analog inputs, digital inputs, and digital out

puts. The recorder has the following settings:

•  number of samples (6-72)

•  recording period (5-60 sec)

•  pre-trigger (0-100%)

•  trigger event (start for recorder)

•  trigger event (stop for recorder)

The recording period depends on the number of samples. The recorder

can be set with the pre-trigger to record event data even before the

event happens.

Stopping the recorder can be triggered by either an event or a preset

time. For easier management and trouble-shooting, event data can be

transferred and analyzed. The data transfer is made by a link through a

plug on the front panel of the SYMAP® device.

Diagnostics and monitoring

SYMAP® provides various diagnostic and monitoring functions:

•  all memories (ROMs, RAMs, EEPROMs)

•  all analog reference voltages

•  automated test sequences

•  control power ON/OFF

•  binary input and output for control logic

ABB SYMAP Digital Protection Relays Event history

Detailed protection function history

SYMAP® automatically collects and stores all activated events related to

protection functions with a time stamp. A maximum of 1.000 protection

function events can be stored. In case of overflow, overwriting follows

the FIFO principle.

Event history

SYMAP® automatically collects and stores all activated events with their

number, title, appearing and disappearing status and a time stamp. A

maximum of 5.000 events can be stored. In case of overflow, overwriting

follows the FIFO principle. The event history can be transferred to a PC

and evaluated by a PC tool. Regardless of power supply, the data store is permanent.

The following supervising systems are offered by SYMAP®:

•  self-diagnostics

•  inputs of analog data (auxiliary circuit)

•  status and position of switching device and motor’s on-off status

•  supervising supply of trip coil

•  gas pressure

• temperature inside panel

•  each operating life of breaker (hours)

ABB SYMAP Digital Protection Relays Communication

Communication

SYMAP® can serve as the main bay controller for the power management

system or substation system. The following list shows the station system

items available through  SYMAP®:

• remote supervision

•  remote control

•  remote parameter setting

•  central registration of measured and calculated values

•  central event logging

•  central fault recording, analysis and logging

•  plant power management

Communication interfaces

SYMAP® provides communication ports available with the following

interfaces and protocols:

•  1 x RS 232 on the front panel for programming and data output

•  1 x RS 422/485 port

• 1 x PROFIBUS DP (RS485 or fiber optic port)

•  MODBUS RTU

•  MODBUS TCP (RJ45 or fiber optic port)

•  IEC 60870-5-103 (RS485 or fiber optic port)

•  IEC 61850 (RJ45 or fiber optic port)

•  CANBUS 1 (communication between devices as power management

system, breaker control interlocking)

•  CANBUS 2 (engine control interface: MTU, VOLVO, DEUTZ etc.)

ABB SYMAP Digital Protection Relays Human Features

Features and interfaces

Terminal connections

All connections to SYMAP® are made with terminal plugs on the back of

the device, allowing the device to be exchanged easily.

Analog input for measurement

SYMAP® provides inputs for analog sensors at the rear of the device. If

terminal plugs for the CTs are disconnected, the circuits will be linked

automatically so there is no disconnection in the CT circuit loops.

A total of 17 analog inputs for current and voltage transformers are used

for protection functions. The following list shows possible connections

for current transformers (CT) and potential transformers (PT):

•  3 x CT inputs for feeder current

•  1 x CT input for ground current

•  3 x PT inputs for feeder voltage

•  3 x PT inputs for 1st bus bar voltage

•  3 x PT inputs for 2nd bus bar voltage

•  1 x PT input for ground voltage

ABB SYMAP Digital Protection Relays

The hotkey »Alarm« displays

all active alarms, event log and blockings. »Process« shows all process data such as the synchro

nization display, motor thermal indication and a counter of breaker operations. Under »Breaker

Control«, up to five breakers can be accessed and controlled.

When programming breaker controls the user has access to various layout configurations via a

library. Programmed blockings remain active when manual control of the breaker is used. Each of

the highlighted breakers in the LCD can be further controlled by the keys »O« and »I«.

For security, access to SYMAP®’s parameter and breaker control data is protected by a code system,

accessed by a password.