Welcome to the official website of CNIACS Automation Technology Co., Ltd!

ABB REF610 Feeder Line Protection Relay Product Applications

Applications

The REF610 is a multifunctional relay designed primarily for the protection

of incoming and outgoing lines in medium voltage distribution substations.

In industrial and utility applications, the relay can also be used as backup protection for motors,

transformers and generators.

The relay incorporates a number of protection features including three levels of overcurrent protection,

two levels of non-directional ground fault protection and thermal protection to provide comprehensive

overcurrent and ground fault protection.

An optional arc protection function can be used to detect arcing conditions in air-insulated metal-clad

switchgear,and an automatic reclosing function can be used to automatically clear overhead line faults.

These features further expand the range of applications for the relays.

The large number of digital input and output contacts allows a wide range of applications.

ABB REF610 Feeder Line Protection Relay Product Manual Feeder protection relays

* HMI with alphanumeric LCD and navigation buttons

* Eight programmable LEDs

* Multiple language support

* User-selectable password protection for the HMI

* Display of primary current value

* Demand value

* All settings can be modified via PC

* Optical front communication connection: wireless or cable

* Optional rear communication module with plastic fiber optic, combined fiber optic (plastic and glass) or RS-4 connection.

(Optional rear communication module with plastic fiber optics, combined fiber optics (plastic and glass) or RS-485 connection for use with the

SPA bus, IEC 60870-5-103. or Modbus (RTU and ASCII) communication protocols for system communication.

* Optional DNP 3.0 rear communication module with RS-485 connection for system communication using DNP 3.0 communication protocols

* Battery backup for real-time clock

* Battery charge monitoring

* Continuous self-monitoring of electronics and software

* Removable plug-in unit

ABB REF610 Feeder Line Protection Relay Product Manual

Feeder protection relays

Technical Reference Manual

REF610 1MRS755310* Two galvanically isolated digital inputs and three additional galvanically isolated

digital inputs on the optional I/O module.

Two galvanically isolated digital inputs and three additional galvanically isolated digital inputs on optional

I/O modules

* Interference logger:

* Recording time up to 80 seconds.

* Triggered by one or more internal or digital input signals

* Records four analog channels and up to eight user-selectable digital channels

* Adjustable sampling rate

* Non-volatile memory for

* Up to 100 time-stamped event codes

* Set values

* Interference logger data

* Time-stamped logging data for the last five events

* Number of AR shots and protection phase starts/trips

* Operating indication messages and LEDs showing status in case of power failure

ABB REF620 IEC Feeder Protection and Measurement Control Unit Key benefits

The REF620 is a member of the 620 Protection, Measurement and Control product family within the ABB Relion® product family.

Key benefits

Protection, control, monitoring and management integrated in a single relay provides a compact and versatile solution for public and industrial power distribution systems

Wide range of protection and control functions, either with sensors or conventional CTs and PTs

Functional scalability and wide range of applications allow users to easily customize configuration applications to meet specific requirements

Pluggable design for quick installation and testing

Large LCD screen with single-line graphic display, accessible locally or via an easy-to-connect and navigate HMI

Thoughtful product lifecycle service

Key Features

Wide range of protection and control functions for incoming or outgoing applications

Multi-frequency conductive earth protection package with high sensitivity and selectivity

State-of-the-art, fast short-circuit and earth fault localization

Several optional function packages – for distributed generation, capacitors, basic motor and arc-light protection

Supports IEC61850 Version 1 and Version 2. including redundant HSR and PRP, GOOSE and IEC61850-9-2

Supports Modbus, DNP3. IEC 60870-5-103 communication protocols and different time synchronization methods, including IEEE 1588 v2 precision time protocols

Emerson DeltaV™ Digital Automation System Overview Hardware

DeltaV System Overview

This chapter gives an overview of the DeltaV digital automation system. It takes a

brief look at the hardware, describes the basic concepts and terminology, introduces

the major software components, and ends with a summary of the ways you can find

out more about the DeltaV system from the Help and Books Online.

Hardware

The manual, Installing Your DeltaV Digital Automation System, also available as an online

book, describes the DeltaV system hardware and provides instructions for installing

and powering up the system.

Emerson Product Description DeltaV SD Plus Controller WirelessHART I/O card

The I/O subsystem also supports Serial interface cards as well as the Ethernet I/O interface.

These various I/O products provide a wide range of interfaces to meet the needs of your control application.

The SD Plus also supports CHARMS and WirelessHART IO cards.

The CHARMS I/O card (CIOC) connects via the redundant Ethernet

ports of the controller and provide a highly distributed and flexible I/O solution called Electronic Marshalling.

Up to 16 CIOC’s can communicate with one controller, each providing up to 96 individually configurable signal types.

The WirelessHART I/O card provides redundant communication for up to 100 WirelessHART devices,

providing high availability and reliability of wireless data.

Up to 16 Wireless HART I/O cards can communicate to a single controller.

Control modules are automatically scheduled by the controller, based on their assigned scan rates.

This allows each control function to be optimized based on the process dynamics.

Modules scan times can be set as fast as 100 ms, and as slow as 60 seconds.

The number of control modules that can be assigned to a controller depends

on the complexity and scan rate of each module, and the available CPU and memory.

Emerson Product Description DeltaV SD Plus Controller

Product Description

The SD Plus controller executes control logic based on the process signals derived

from the I/O subsystem and provides communication to the rest of

the DeltaV control system for operator interaction and data collection.

Each controller node can be installed as a simplex or redundant node.

Redundancy is provided by adding a second controller and power supply

mounted adjacent to the primary controller.

The controllers are connected to the I/O carriers, which are mounted to the right of the controller carriers.

Up to 8 carriers with 8 cards each can be connected to the local bus I/O, for a total of 64 traditional I/O

cards.

In addition to the 8 local I/O carriers, each controller can communicate

with an additional 16 Remote I/O units hosting traditional card based I/O.

In addition to traditional I/O cards, the local bus supports field bus technologies,

including Foundation fieldbus, Profibus DP, DeviceNet and AS-I protocols.

Emerson DeltaV SD Plus Controller Introduction

 Scalable controllers

 Quick Assembly

 Easy to use

 Field Proven architecture

 Designed for Digital Marshalling

 Advanced Controls

Introduction

The DeltaV S-Series controllers provide communication and control functions and integrate

field devices and the other nodes on the control network.

The SX and SD Plus controllers provide a choice to match the controller capacity to the requirements of the process.

They also provide new ease of use features that eliminate mounting screws and accelerate cabinet assembly.

Control strategies and system configurations created on earlier DeltaV systems can be used with this controller.

The SD Plus Controller provides all the features and functions of the M-Series controllers with the added support for CHARM based Digital Marshalling.

The control languages executed in the controllers are described in the Control Software product data sheet

Emerson M-series Virtual I/O Module Benefits

Benefits

Non-Intrusive DeltaV I/O simulation. Use the VIM2 in conjunction with the

MYNAH Technologies’ MiMiC Simulation Software to simulate your DeltaV M-Series I/O and digital bus field devices.

 Supports DeltaV I/O modules. Provides completely non-intrusive simulation of all DeltaV M-series I/O Modules.

Supports autosensing of I/O and accurate testing of controller loading.

DeltaV configuration can be fully tested without modifying the control strategies.

 Digital bus support. Provides simulation of all DeltaV Digital Busses and Foundation Fieldbus function blocks.

Supports Foundation Fieldbus control in the field configuration testing.

 Powerful simulation solution. Provides full simulation of up to 64 DeltaV I/O modules per controller.

Simulation execution is fast and efficient; the DeltaV controller thinks it’s talking with real IO.

Emerson M-series Virtual I/O Module 2 Introduction

Introduction

The DeltaV M-series Virtual I/O Module 2 (VIM2) provides nonintrusive simulation of the

DeltaV M-series I/O Cards and digital bus field devices for process simulation

when used with MYNAH Technologies’ MiMiC Simulation Software.

DeltaV Control strategies and system configurations can be fully tested with this powerful simulation interface.

The VIM2 also provides an interface to Ethernet I/O networks and devices that

use the Modbus TCP/IP or Ethernet/IP protocol drivers.

DeltaV M-series controllers can read and write signals from plant floor devices connected

to Ethernet I/O networks such as PLC’s, Motor Control Centers, and Weigh Scales.

Powerful integration solution. Use the VIM2 in conjunction with the MYNAH

Ethernet I/O drivers to integrate your DeltaV system with your Ethernet I/O device networks.

 Large device capacity. Each VIM emulates four DeltaV Serial Cards and support up

to 128 Serial Card Datasets of information from 32 network devices in simplex installations and 16 devices in redundant installations.

Communication over the Ethernet I/O device network is fast and efficient.

 Flexible networking. User configurable IP addressing allows the VIM2 to be used in almost any

plant environment regardless of networking scheme.

Search for products

Back to Top
Product has been added to your cart