IBA ibaBM-ENetIP EtherNet/IP-Busmonitor Overview

The sampling rate and the data formats can be configured flexibly.

Overview of the most important characteristic values:

 TAP interface for sniffer function

 Monitor interface for connecting a network analysis tool

 Data acquisition with ibaPDA

 Simple configuration and measurement via bidirectional FO connection with ibaNet

protocol 32Mbit Flex

 Flexible configuration of sampling rate and data formats with 32Mbit Flex

Scope of delivery

After having unpacked the delivery, please check if it is complete and intact.

The following components are included in delivery:

 ibaBM-ENetIP device

 ibaBM-ENetIP manual

 DVD “iba Software & Manuals”

Designated use

The device is an electrical equipment. It may only be used for the following applications:

 Measurement data acquisition and measurement data analysis

 Automation of industrial plants

 Applications of iba software products (e.g ibaPDA) and iba hardware products

The device may only be used as defined in the “Technical Data” chapter.

IBA ibaBM-ENetIP EtherNet/IP-Busmonitor

Introduction

EtherNet/IP (EtherNet Industrial Protocol) is a real-time Ethernet which is mainly used in

automation technology.

The EtherNet/IP bus monitor ibaBM-ENetIP is a device for acquiring the cyclical data

exchange between EtherNet/IP scanner (master) and adapters (slaves). The device can

be integrated into an existing EtherNet/IP network with one or more EtherNet/IP scan

ners (master).

The ibaBM-ENetIP bus monitor can be operated in an EtherNet/IP network without inter

ferences using the TAP interface (Ethernet). The device works as sniffer, i.e. it listens to

the cyclic data exchange of the IO data (implicit messaging) between EtherNet/IP scan

ner (master) and adapters (slaves).

The entire communication via the TAP interface is being mirrored to a monitor port and

can be recorded using an external network analysis tool.

On the optical-fiber side, ibaBM-ENetIP works with the ibaNet protocol 32Mbit Flex. With

this protocol, measuring and configuration data are transferred via a bidirectional fiber

optic connection. 

IBA ibaLink-SM-128V-i-2o VMEbus Interface Card Application 2

Whether the link sends in integer or float format must be defined prior to installing the

SM128V. Use the DIP switch to change this setting for each fiber optic link. Each fiber

optic link must be set independently. Data must then be written to the appropriate regis

ters.

The digital channel values may be written in channel-wise in either a DWORD for each

digital channel (bit 0 of each DWORD) or an 8 byte bit mask. Prior to sending the tele

gram the respective registers are OR’d to determine whether a 0 or 1 is sent in the tel

egram. For this reason, it is important to reset the registers of the unused method.

It’s an asynchronous take-over of data from the VME range into the buffer of the FOB

transmitter. Data coming out of the VME range will be synchronized with the 1 ms clock

of the FOB interface. Thus the take-over time for the data varies between 0 and 1 ms.

IBA ibaLink-SM-128V-i-2o VMEbus Interface Card VMEbus interface

The following devices are compatible with fiber-optic channel 2 of the SM128V:

 ibaPADU-8-O,

 ibaLink-SM-64-SD16.

 ibaBM-DPM-S-64.

 ibaFOB-4i-S and ibaFOB-io-S (Input),

 ibaFOB-4i-D, ibaFOB-2i-D and ibaFOB-io-D (Input),

 ibaBM-FOX-i-3o and ibaBM-FOX-i-3o-D,

 ibaBM-COL-8i-o

Both fiber-optic output channels (Channel 1 and Channel 2) can be interfaced to indi

vidual ibaCom-PCMCIA-F cards via the X4 and X5 RJ11 sockets. Note that only one

ibaCom-PCMCIA-F card may be used at a time in a Notebook measurement PC.

The VMEbus interface

The SM128V supports a maximum of 64 input channels (a + d) and 128 output chan

nels. The card occupies 256 kByte memory space on the VMEbus. The base VME ad

dress is adjustable using the DIP switch settings as described above.

From the VMEbus viewpoint, WORDs and DWORDs can be read and written in BIG

ENDIAN or LITTLE ENDIAN format. The SM128V-card can accept both formats. The

used format has to be configured with a DIP switch.

IBA ibaLink-SM-128V-i-2o VMEbus Interface Card Application

Application Notes

The optical fiber input/output links operate at 3.3 Mbps.

The following components are compatible with fiber-optic channel 1 of the SM128V:

 ibaLink-SM-64-io (but mixed cascade of ibaLink-SM-64-io and SM128V is not sup

ported),

 ibaLink-SM-64-SD16.

 ibaBM-DPM-S-64.

 ibaPADU-8. ibaPADU-8-I, ibaPADU-8-O,

 ibaFOB-4io-S and ibaFOB-io-S,

 ibaFOB-4io-D, ibaFOB-2io-D and ibaFOB-io-D,

 ibaBM-FOX-i-3o and ibaBM-FOX-i-3o-D,

 ibaBM-COL-8i-o, ibaBM-DIS-i-8o

The following operation modes are supported on channel 1:

 I/O operation; up to eight devices connected to the fiber-optic input (Rx) and up to

eight devices connected to the fiber-optic output (Tx)

 Cascade operation with daisy-chain of up to eight SM128V cards

 Addressing of input and output data in steps of eight signals.

Channel 2 provides 64 channels for transmission only.

IC693CMM321 Ethernet Interface Module Restart Button


Four LEDs are located at the top of the board.  The Restart pushbutton is located immediately

below the LEDs.  The RS-232 serial port with the RJ-11 connector is the Station Manager port.

The RS-485 serial port with the 15-pin D connector located below the Station Manager port is the

module’s Downloader port.  The 14-pin AAUI connector, facing downward, is the Transceiver

port.  The Default MAC Address label is attached to the outside of the plastic housing.

Board Indicators

There are four LEDs on the Ethernet Interface:  OK, LAN, SER, and STAT.  These LEDs can be

ON, OFF, BLINKING slow, or BLINKING fast.  They indicate the state the Interface is in, traffic

on the Transceiver port and Downloader port, and when an exception event has occurred.

Restart Button

The Restart button serves four functions:  LED test, Restart, Restart and Reload, and Restart and

Enter Maintenance Utility.  The Restart button is inaccessible when the front cover of the Ethernet

Interface is closed.

Serial Ports

There are two serial ports on the Ethernet Interface:  the Station Manager Port and the Downloader

Port.

The Station Manager Port.  This RS-232 port is used to connect a terminal or terminal emulator

to access the Station Manager software on the Ethernet Interface.  This port uses a  6-pin, RJ-11

connector.  The IC693CBL316 Station Manager cable is ideal for connecting to this port (see

Chapter 10 for details).

The Firmware Upgrade Port.  The 15-pin, D-type, RS-485 port is used to connect to the PC

Downloader in case the communications software in the Ethernet Interface needs to be updated.

Use the IC690ACC901 miniconverter/cable kit for this connection (see Appendix E for details).

IC693CMM321 Ethernet Interface Module

The Ethernet Interface module (IC693CMM321) provides an interface that allows you to attach the

Series 90-30 PLC to an Ethernet LAN via an external transceiver and AAUI cable, and to

communicate with hosts and other control devices on the network.

The Ethernet Interface for the Series 90-30 PLC has client/server capability.  As a client it can

initiate communications with other PLCs containing Ethernet Interfaces.  This is done from the

ladder program using the COMMREQ Function Block.  As a server it responds only to requests

from other devices such as a Host computer running a Host Communications Toolkit application or

another Series 90-30 PLC acting as a client.

The Ethernet Interface allows you to:

Directly attach your PLC to an Ethernet network

Initiate transfer of data to the PLC from another device

Communicate simultaneously to multiple devices with up to 16 server connections

Interface with other GE Fanuc devices, as well as with devices from other vendors

Communicate from a Host computer (or other control device)

Diagnose and maintain your system using diagnostic and station management tools

The Ethernet Interface does not support the Series 90-30/20/Micro Hand-Held Programmer.  Either

one or two Ethernet Interface modules can be installed in any Series 90-30 baseplate.

The Ethernet Interface connects to an Ethernet network through an external SQE enabled

transceiver (GE Fanuc catalog no. IC649AEA102 or IC649AEA103 or equivalent.  See Appendix

J).  The following figure shows the layout of the Ethernet Interface.

8751-CA-NS ELFD Controller Carrier

The ELFD Controller Carrier provides a mounting platform for up to two SafetyNet Controllers (8851-LC-MT) .

It can also accommodate a Power Supply Monitor module (8410-NS-PS)

which can monitor the health of up to two 8913-PS-AC,

four 8914-PS-AC power supplies and the 12V supply to Intrinsically Safe Modules (when these are used) .

For each Controller there is a serial port connector and a manually operated ““Change State” button .

The Carrier also provides terminals that are used when earth leakage fault detection is required.

PLC CPUs IC697CPX928 Central Processing Unit Installation 2

Operation, Protection, and Module Status

Operation of this module can be controlled by the

three-position RUN/STOP switch or remotely by an

attached programmer and programming software.

Program and configuration data can be locked

through software passwords or manually by the

memory protect keyswitch.  When the key is in the

protected position, program and configuration data can

only be changed by a programmer connected parallel

only (to the Bus Transmitter module).  The status of a

CPU is indicated by the seven green LEDs on the

front of the module.

Operating Temperature

The CPX 928 requires forced air cooling for proper

operation in ambient temperatures greater than 50C

(122 F).  A fan capable of 70 CFM (including filters)

should be located beneath slot 1 of the rack containing

the CPU.

Fan assemblies (IC697ACC 721. IC697ACC724. and

IC697ACC744) can be ordered for direct mounting on

the IC697 rack.  Refer to the applicable Programmable

Controller Installation Manual for detailed information.

Installation

It is the responsibility of the OEM, system integrator,

or end user to properly install the PLC equipment for

safe and reliable operation.  Product manuals provide

detailed information about installation, startup, and

proper use of the PLC equipment.  The installation

manual, shipped with your PLC programming

software, describes how to properly install the

equipment.

If the PLC installation must comply with supported

standards, such as FCC or CE Directives, please refer

to the Installation Requirements for Conformance to

Standards, shipped with the PLC programming

software, for additional guidelines.

Installation should not be attempted without refer

ring to the applicable Programmable Controller Installa

tion Manual.

PLC CPUs IC697CPX928 Central Processing Unit Firmware Storage

User RAM Memory

The CPX928 has a built-in memory board with 6

Mbytes of battery-backed CMOS RAM memory for

user data (program, configuration, and register data)

storage.

User Flash Memory

The CPX928 has 256K of built-in, non-volatile flash

memory for user data (program, configuraton, and

register data) storage.  Use of this flash memory is

optional.

Firmware Storage in Flash Memory

This CPU uses flash memory for storing the operating

system firmware.  This allows firmware to be updated

without disassembling the module or replacing

EPROMs.  The operating system firmware is updated

by connecting a PC compatible computer to the mod

ule’s serial port and running the software included

with the firmware upgrade kit.