ABB IGBT MODULE KIT FS450R12KE3/AGDR-71C S 68569354


TIM foils or otherwise known as graphite sheet have been introduced in use in ACS800 R7i &

R8i industrial air-cooled modules as part of normal continuous improvements in the ACS800

product family. Benefits of using TIM foils in comparison to thermal grease are easier installa

tion and more durable heat transferring properties for longer periods of time. Durability par

ticularly improved in a cyclic application.

New ACS800 R7i & R8i industrial air-cooled modules have been built using TIM foils since

1.10.2022. when ordering the module through BOL Drives Configurator. Current industrial air

cooled ACS800 R7i & R8i module fixed codes are available until 31.12.2022 and are delivered

with the thermal grease. All industrial air-cooled ACS800 R7i & R8i module orders will be avail

able only through BOL Drives Configurator starting 1.1.2023.

NOTE: Spare part wind specific modules with fixed codes will continue to be available and are

delivered with thermal grease and the wind specific DSW module repairs and other services

continue to use thermal grease until further notice.

All industrial air-cooled ACS800 R7i & R8i module repairs in Helsinki DSW are done with TIM

foil. DSW: s global implementation date for TIM foil is 1.11.2022.

ABB IGBT MODULE KIT FS225R17KE3/AGDR-76C S 68569583

Overview

TIM foils or otherwise known as graphite sheet have been introduced in use in ACS800 R7i &

R8i industrial air-cooled modules as part of normal continuous improvements in the ACS800

product family. Benefits of using TIM foils in comparison to thermal grease are easier installa

tion and more durable heat transferring properties for longer periods of time. Durability par

ticularly improved in a cyclic application.


NOTE: Spare part wind specific modules with fixed codes will continue to be available and are

delivered with thermal grease and the wind specific DSW module repairs and other services

continue to use thermal grease until further notice.

All industrial air-cooled ACS800 R7i & R8i module repairs in Helsinki DSW are done with TIM

foil. DSW: s global implementation date for TIM foil is 1.11.2022.

All spare part IGBT kits for R7i & R8i have been available with TIM foils since 1.10.2022

IGBT MODULE KIT     FS450R12KE3/AGDR-61C S TIM FOIL SP       3AXD50000951369

IGBT MODULE KIT     FS300R17KE3/AGDR-66C S TIM FOIL SP       3AXD50000951376

IGBT MODULE KIT     FS300R12KE3/AGDR-62C S TIM FOIL SP       3AXD50000951383

IGBT MODULE KIT     FS450R17KE3/AGDR-61C S TIM FOIL SP       3AXD50000951390

IGBT MODULE KIT     FS225R12KE3/AGDR-71C S TIM FOIL SP       3AXD50000951406

IGBT MODULE KIT     FS300R12KE3/AGDR-72C S TIM FOIL SP       3AXD50000951628

IGBT MODULE KIT     FS450R12KE3/AGDR-71C S TIM FOIL SP       3AXD50000951635

IGBT MODULE KIT     FS225R17KE3/AGDR-76C S TIM FOIL SP       3AXD50000951642

IGBT MODULE KIT     FS300R17KE3/AGDR-76C S TIM FOIL SP       3AXD50000951659

IGBT MODULE KIT     FS450R17KE3/AGDR-71C S TIM FOIL SP       3AXD50000951666

ABB IGBT MODULE KIT FS300R17KE3/AGDR-76C S 68569362

Where and how to use

TIM foils are used to transfer the heat generated in the IGBT’s to the heatsink. Full instruc

tions on how to install TIM foils is described in document delivered with TIM IGBT spare part

kits. In R8i module it’s possible to use a mix of IGBT’s with thermal grease and TIM foils. In

parallel connected R8i modules it’s also possible to use a mix of modules using TIM foils and

thermal grease.

New ACS800 R7i & R8i industrial air-cooled modules have been built using TIM foils since

1.10.2022. when ordering the module through BOL Drives Configurator. Current industrial air

cooled ACS800 R7i & R8i module fixed codes are available until 31.12.2022 and are delivered

with the thermal grease. All industrial air-cooled ACS800 R7i & R8i module orders will be avail

able only through BOL Drives Configurator starting 1.1.2023.

ABB IGBT MODULE KIT FS450R17KE3/AGDR-71C S 68569591

The input voltage range is 18 to 30 volt dc and the input current

source is 6 mA at 24 V. The inputs are divided into two individualy

isolated groups with eight channels and one voltage supervision

input in each group. Every input channel consists of current limiting

components, EMC protection components, input state indication

LED and optical isolation barrier. The process voltage supervision

input give channel error signals if the voltage disappears. 

The error signal can be read through the ModuleBus.

Features and benefits

• 16 channels for 24 V d.c. inputs with current sinking

• 2 isolated groups of 8 with voltage supervision

• Input status indicators

IGBT MODULE KIT FS450R12KE3/AGDR-61C S TIM FOIL SP   3AXD50000951369
IGBT MODULE KIT FS300R17KE3/AGDR-66C S TIM FOIL SP   3AXD50000951376
IGBT MODULE KIT FS300R12KE3/AGDR-62C S TIM FOIL SP   3AXD50000951383
IGBT MODULE KIT FS450R17KE3/AGDR-61C S TIM FOIL SP   3AXD50000951390
IGBT MODULE KIT FS225R12KE3/AGDR-71C S TIM FOIL SP   3AXD50000951406
IGBT MODULE KIT FS300R12KE3/AGDR-72C S TIM FOIL SP   3AXD50000951628
IGBT MODULE KIT FS450R12KE3/AGDR-71C S TIM FOIL SP   3AXD50000951635
IGBT MODULE KIT FS225R17KE3/AGDR-76C S TIM FOIL SP   3AXD50000951642
IGBT MODULE KIT FS300R17KE3/AGDR-76C S TIM FOIL SP   3AXD50000951659
IGBT MODULE KIT FS450R17KE3/AGDR-71C S TIM FOIL SP   3AXD50000951666

ABB IGBT MODULE KIT FS450R17KE3/AGDR-72C S 68569427


TIM foils or otherwise known as graphite sheet have been introduced in use in ACS800 R7i &

R8i industrial air-cooled modules as part of normal continuous improvements in the ACS800

product family. Benefits of using TIM foils in comparison to thermal grease are easier installa

tion and more durable heat transferring properties for longer periods of time. Durability par

ticularly improved in a cyclic application.

NOTE: Spare part wind specific modules with fixed codes will continue to be available and are

delivered with thermal grease and the wind specific DSW module repairs and other services

continue to use thermal grease until further notice.

All industrial air-cooled ACS800 R7i & R8i module repairs in Helsinki DSW are done with TIM

foil. DSW: s global implementation date for TIM foil is 1.11.2022.

All spare part IGBT kits for R7i & R8i have been available with TIM foils since 1.10.2022

ABB ACS800 Inverter   IGBT Module
IGBT MODULE KIT FS450R12KE3/AGDR-61C S 64635875
IGBT MODULE KIT FS300R17KE3/AGDR-66C S 64717839
IGBT MODULE KIT FS300R12KE3/AGDR-62C S 64717812
IGBT MODULE KIT FS450R17KE3/AGDR-61C S 64783831
IGBT MODULE KIT FS225R12KE3/AGDR-71C S 68569303
IGBT MODULE KIT FS300R12KE3/AGDR-72C S 68569541
IGBT MODULE KIT FS450R12KE3/AGDR-71C S 68569354
IGBT MODULE KIT FS225R17KE3/AGDR-76C S 68569583
IGBT MODULE KIT FS300R17KE3/AGDR-76C S 68569362
IGBT MODULE KIT FS450R17KE3/AGDR-71C S 68569591
IGBT MODULE KIT FS450R17KE3/AGDR-72C S 68569427
IGBT MODULE KIT FS300R12KE3/AGDR-71C S 68569346
IGBT MODULE KIT FS450R17OE4/AGDR-71C S TIM FOIL SP 3AXD50000948185

ABB IGBT MODULE KIT FS300R12KE3/AGDR-71C S 68569346

The input voltage range is 18 to 30 volt dc and the input current

source is 6 mA at 24 V. The inputs are divided into two individualy

isolated groups with eight channels and one voltage supervision

input in each group. Every input channel consists of current limiting

components, EMC protection components, input state indication

LED and optical isolation barrier. The process voltage supervision

input give channel error signals if the voltage disappears. 

The error signal can be read through the ModuleBus.

Features and benefits

• 16 channels for 24 V d.c. inputs with current sinking

• 2 isolated groups of 8 with voltage supervision

• Input status indicators

New ACS800 R7i & R8i industrial air-cooled modules have been built using TIM foils since

1.10.2022. when ordering the module through BOL Drives Configurator. Current industrial air

cooled ACS800 R7i & R8i module fixed codes are available until 31.12.2022 and are delivered

with the thermal grease. All industrial air-cooled ACS800 R7i & R8i module orders will be avail

able only through BOL Drives Configurator starting 1.1.2023.

ABB IGBT MODULE KIT FS450R17OE4/AGDR-71C S TIM FOIL SP 3AXD50000948185

Overview

TIM foils or otherwise known as graphite sheet have been introduced in use in ACS800 R7i &

R8i industrial air-cooled modules as part of normal continuous improvements in the ACS800

product family. Benefits of using TIM foils in comparison to thermal grease are easier installa

tion and more durable heat transferring properties for longer periods of time. Durability par

ticularly improved in a cyclic application.

NOTE: Spare part wind specific modules with fixed codes will continue to be available and are

delivered with thermal grease and the wind specific DSW module repairs and other services

continue to use thermal grease until further notice.

All industrial air-cooled ACS800 R7i & R8i module repairs in Helsinki DSW are done with TIM

foil. DSW: s global implementation date for TIM foil is 1.11.2022.

The input voltage range is 18 to 30 volt dc and the input current

source is 6 mA at 24 V. The inputs are divided into two individualy

isolated groups with eight channels and one voltage supervision

input in each group. Every input channel consists of current limiting

components, EMC protection components, input state indication

LED and optical isolation barrier. The process voltage supervision

input give channel error signals if the voltage disappears. 

The error signal can be read through the ModuleBus.

A-B 1747-DCN Introduction Distributed I/O Scanner

DIO System Overview

The DIO system consists of an SLC processor, a scanner, an Isolated Coupler

and I/O blocks. These devices form the DIO System when they are properly

connected to the DIO Link and the DH–485 Data Link as shown below. The

DIO Link and the DH–485 Data Link are independent networks.

The DIO Link consists of the scanner and I/O blocks. It enables the SLC

processor to exchange input and output information with up to 30 I/O blocks.

Output data is transferred from the SLC processor to the scanner, which then

transmits the data to the appropriate I/O block via the DIO Link. The

scanner receives input data from the I/O blocks via the DIO Link. The

scanner then provides this data to the SLC processor. The maximum length

of the DIO Link is 2,500 feet (762 meters) using Belden 9463 cable.

The SLC processor and programming devices communicate using the

DH–485 Data Link. The DH–485 port located on each I/O block allows

remote programming and/or monitoring of the SLC processor. It does not

directly control the I/O block.

Connecting a programming device to any I/O block programming port allows

the programming device to communicate with the SLC processor. The

maximum length of the DH–485 Data Link is 4,000 feet (1,219 meters) using

Belden 9842 cable.

A-B 1747-DCM Direct Communication Module

System Overview

The Direct Communication Module, catalog number 1747-DCM, connects any

SLC 500 programmable controller with expansion chassis or SLC 500 Modular

Programmable Controller to a supervisory Allen-Bradley programmable controller

via the RIO Link, providing a distributed processing system. The 1747-DCM allows

these supervisory processors to transfer data between one another. The 1747-DCM

appears as an RIO adapter to:

• a PLC processor with integral RIO scanner on the RIO Communication Link

• an RIO scanner, catalog number 1771-SN or 1747-SN, on the RIO

Communication Link

The 1747-DCM can physically reside on the RIO Link with any other adapter. It is

compatible with all RIO scanners.

1747-DCM Modules are connected in a daisy-chain configuration using

Belden™ 9463 cable. See the example below.

Extended Node Capability

The 1747-DCM features extended node capability. Extended node capability allows

you to have up to 32 adapters on the RIO link using an 82Ω termination resistor at

both ends of the RIO link for all baud rates.

IMPORTANT Extended node capability can only be used if the scanner and all

adapters on the RIO link have extended node capability.

A-B 1747-BSN Backup Scanner Module

Overview

The 1747-BSN Backup Scanner Module provides a high-speed communication

channel between two modular SLC 500™ (5/02 or higher) processors. The 1747-

BSN backup system uses a set of modules, with one or more 1747-BSN modules

residing in the primary system and one or more complementary modules in the

secondary or backup system. The primary system controls the operation of

remote I/O, while the secondary system monitors communications via the highspeed

serial link (HSSL) and is available to take over control in the event of a

fault in the primary system.

The backup scanner has the capability to switch between two communication

channels. The first channel is configurable as Remote I/O (RIO) or Data

Highway Plus™ (DH+). The second channel is used to switch one RS232/485

channel in order to provide connection for electronic operator interfaces.

A backup system using the 1747-BSN modules supports up to eight BSN

modules in each processor chassis, connected by a local status link (LSL). Only I/

O residing in remote chassis is backed up. Local I/O is not backed up. Examples

of RIO and DH+ system configurations are shown in Figures 1 and 2 on page 6.

Note: During the transfer of control from one processor to

another (switchover), the output modules in the remote

chassis maintain their last state until the secondary

processor program takes control.

Search for products

Back to Top
Product has been added to your cart