Prosoft AN-X2-ABRIO-EIPSCN Remote I/O to Ethernet/IP Scanner Module

The AN-X emulates a ControlLogix scanning I/O over Ethernet.

All configuration data comes from the AN-X, not from remote I/O. Configuration

options correspond to what’s available in a ControlLogix, not to what is available in

remote I/O. No configuration data gets passed from remote I/O to Ethernet. If your

program dynamically changes configuration data, or if it contains logic to configure a

module, the program will have to be modified to remove or disable that logic.

You may need to make some changes to the control application related to addresses, logic

and timing.

Some behaviour that is set by switches on the remote I/O adapter is set in parameters for

Ethernet modules. For example, hold last state is set on a module-by-module basis when

you scan over Ethernet.

In addition, you may need to make changes because Ethernet does not support

complementary I/O, or standard 32 or complementary 32 addressing.

For example, 32 bit discrete Flex I/O modules require a separate Ethernet connection.

You must communicate with them from remote I/O using block transfers, not as discrete data.

Prosoft AN-X2-ABRIO-EIPSCN Remote I/O to Ethernet/IP Scanner Module Overview

AN-X2-ABRIO-EIPSCN Module Overview

The AN-X2-ABRIO-EIPSCN communications module connects a scanner such as a

PLC-5 on an Allen-Bradley remote I/O network to I/O modules on Ethernet/IP.

As parts become obsolete and remote I/O adapters become unavailable, the

AN-X2-ABRIO-EIPSCN is a solution that lets you retain the original controller, I/O

modules and field wiring and replace remote I/O adapters with Ethernet adapters. The

existing remote I/O scanner talks to the AN-X, which maps discrete and analog I/O on

remote I/O to Ethernet data.

In addition, you may need to make changes because Ethernet does not support

complementary I/O, or standard 32 or complementary 32 addressing.

For example, 32 bit discrete Flex I/O modules require a separate Ethernet connection.

You must communicate with them from remote I/O using block transfers, not as discrete data.

Prosoft EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO Hardware Specifications

Hardware Specifications

Ports

1 RJ45 10/100 Mbps Ethernet port

1 Phoenix 3-pin power connector

1 Phoenix 3-pin connector network connector

Typical Power Consumption

200 mA @ 12 VDC or 100 mA @ 24 VDC

Maximum Power Dissipation

2.4 W

Operating Temp

32°F to 122°F (0 ºC  to 50 ºC)

Storage Temperature -40°F to 185°F (-40 ºC  to 85 ºC)

Dimensions

107 x 126 x 34 mm

(4.18 x 4.97 x 1.33 in)

Not including connectors

Humidity

5% to 95% RH, with no condensation

Prosoft EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO Flex I/O Scanner

DH+

This mode acts as a bridge between an EtherNet/IP and a Data Highway Plus network.

 Programming terminals, and/or processors on an EtherNet/IP network can access legacy processors on a DH+ network

 Download to a PLC5 or SLC through RSLinx

 Configures through web browser

 Supports all DH+ baud rates (57.6. 115.2. and 230.4 K baud)

 Support for DH+ to EtherNet/IP PanelViews upgrades on PLC5 or SLC networks

Flex I/O Scanner

This mode allows PLC’s on Remote I/O to connect to and control 1794-AENT EtherNet/IP Flex adapters.

 Designed to replace obsolete 1794-ASB adapters

 Supports up to 16 EtherNet/IP connections

 Each adapter and rack of discrete count as a single connection. Each analog module counts as a single connection

Prosoft EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO DH+ Scanner

Remote I/O Scanner

This mode allows users to replace their existing Remote I/O PLC with a ControlLogix or CompactLogix PAC

without having to

replace existing racks of I/O.

 Build new controller program without interrupting existing controls, minimizing downtime

 Supports up to 32 racks of Remote I/O

 Supports all Remote I/O baud rates (57.6. 115.2. and 230.4 K baud), and Remote I/O addressing 0 to 76

octal

 Works with both ControlLogix or CompactLogix

 Auto-Configuration utility discovers baud rate and maps discrete I/O reducing configuration errors

DH+

This mode acts as a bridge between an EtherNet/IP and a Data Highway Plus network.

 Programming terminals, and/or processors on an EtherNet/IP network can access legacy processors on

a DH+ network

 Download to a PLC5 or SLC through RSLinx

 Configures through web browser

 Supports all DH+ baud rates (57.6. 115.2. and 230.4 K baud)

 Support for DH+ to EtherNet/IP PanelViews upgrades on PLC5 or SLC networks

Prosoft EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO HMI

DRIVE

This mode supports upgrading legacy Allen Bradley drives on Remote I/O to new EtherNet/IP enabled drives.

 No changes to PLC code required

 Supports up to 4 EtherNet/IP drives

 Configurable with 1/4. 1/2 and full rack addressing

 Supports all PowerFlex drives on EtherNet/IP

HMI

This mode allows legacy PanelViews on Remote I/O or DH+ to be upgraded to a PanelView Plus, PanelView Plus 6 or PanelView

Plus 7 on EtherNet/IP.

 No changes to PLC code required

 Supports up to 8 PanelViews on the same network

 Support for DH+ to EtherNet/IP PanelViews upgrades on PLC5 or SLC networks

Prosoft EtherNet/IP™ to Remote I/O or DH+ Gateway AN-X2-AB-DHRIO DRIVE

The AN-X2-AB-DHRIO Gateway is designed to help customers initiate

a phased migration approach to replacing or upgrading legacy Remote

I/O PLCs, HMI’s, Drives or Flex I/O Adapters. These solutions can be

achieved by selecting the corresponding operation mode during initial

configuration. The AN-X2-AB-DHRIO has a built-in web server that can

display diagnostics data, configuration, upload configuration files, and

set the operation mode.

Note: Now supports DH+ migrations on SLC networks. Some PLC

code change may be required see TN143269-001 DH+ to EIP PV

Migration for SLC networks.pdf for more information.

DRIVE

This mode supports upgrading legacy Allen Bradley drives on Remote I/O to new EtherNet/IP enabled drives.

 No changes to PLC code required

 Supports up to 4 EtherNet/IP drives

 Configurable with 1/4. 1/2 and full rack addressing

 Supports all PowerFlex drives on EtherNet/IP

SBS VIPC616 Four Slot 6U VMEbus IndustryPack Carrier Features

Interrupts are fully supported with a simple but powerful architecture.  Each of the four IPs is able to

generate up to two interrupt requests.  These eight request lines are paired with the seven available

VMEbus

interrupt request levels by a simple jumper block.  Alternatively, a user provided PLD may be installed to

perform arbitrarily complex interrupt mappings.

Front panel IP access acknowledge (ACK) and power check LEDs are provided for visual verification. Two

power check circuits detect blown fuses and line faults on any IP slot. The VIPC616 provides fuse

protection,

RF filtering and de-coupling capacitance on all IP power lines.

Features

• Four IndustryPacks slots on a 6U VME board

• Supports I/O, ID, memory, and interrupt cycles

• Front panel I/O through unshielded right-angle ribbon connectors

• 64 lines of backpanel I/O via P2

• A24 and A32 memory maps available

• Up to 8 Mbytes of memory per slot

• Front panel activity LEDs for each IndustryPack slot

• Front panel power monitor LEDs

• Filtered and fused power rails

• Custom IRQ mapping available via PLD programming

• 100% software compatible with the VIPC618

Merlin Embedded MVIPC-616 4-Slot VMEBus IndustryPack Carrier VME Specifications

VME Specifications

• Conforms with VME Specifications Revision C.1

IEEE Std. 1024/D2

• Board size: 6U

IndustryPack Specification

• ANSI/VITA-4 1995

Power Requirements

• +5V @ 500mA max

• +12V @ 10mA

•-12V @ 10mA

Environmental

• Operating Temperature: 0 to 70 °C

• Storage Temperature: -40 to 85 °C

• Shock: 25g, 11ms on all axis

• Humidity: 80% Rel. Humidity, non-condensing

Merlin Embedded MVIPC-616 4-Slot VMEBus IndustryPack Carrier Specifications

Specifications

• IndustryPack Slots – 4

• I/O Space – A16 space, 128 bytes per IndustryPack slot

• ID Space – A16 space, 128 bytes per IndustryPack slot

• Memory Space – A24 space: none or 128 KB to 2

MB per IndustryPack slot. A32 space: 8 MB per

IndustryPack slot fixed

• Interrupts – IndustryPack interrupts mapped 1:1 to

VME IRQ levels by shunt or PLD selections.

• Front Panel I/O Access – One pair of 50-pin right

angled keyed, shrouded ribbon cable connectors with

ejection hardware for each pair of IndustryPack slots

• Back Panel I/O Access – All 50 I/O pins from slot D

and a configurable selection of 14 pins from slot C

routed to VME bus P2 rows A and C

• Indicators – 1 green LED per slot to indicate

accesses. 1 green LED to show power to slots A and

B. 1 green LED to show power to slots C and D

• IndustryPack Site Features – 8 MHz only. IO cycles,

ID cycles, memory cycles, interrupt acknowledge

cycles. 32-bit interface and IndustryPack DMA are

not supported.