Horner APG Thermocouple Input Module DESCRIPTION

DESCRIPTION

The Horner APG Thermocouple Input Modules allow thermocouple temperature sensors to be directly

connected to the PLC without external signal processing (transducers, transmitters, etc.).  All analog and

digital processing of the thermocouple signal is performed on the module.  These modules have a

resolution of 0.5°C, and temperature values may be reported to the PLC %AI I/O table in 0.5°C or 0.5°F

increments.  There are four standard resolution models available, with four input channels

(HE693THM409/HE693THM449), and with eight input channels (HE693THM809/HE693THM889).  All

models feature open circuit detection, where the temperature value written to the %AI register goes to its

maximum value upon an open circuit condition.  Two models (HE693THM449 and HE693THM889) also

feature %I alarm bits which energize on an open circuit condition.  The first four %I bits are used for the

HE693THM449 and the first eight %I bits are used for the HE693THM889.

Baker Hughes XMTC Panametrics Thermal Conductivity Binary Gas Transmitter


The microprocessor-based XMTC is a compact, rugged,

online thermal conductivity transmitter that measures the

concentration of binary gas mixtures including hydrogen,

carbon dioxide, methane, helium and many others. The analyzer

also combines computer enhanced signal measurement with

fast-response software, real-time error detection and digital

communication via an RS232 or RS485 interface.

Theory of operation

Two ultrastable, precision glass-coated thermistors are used—

one in contact with the sample gas and the other in contact

with the reference gas (such as air in a sealed chamber). The

thermistors are mounted so that they are in close proximity

to the stainless steel (or Hastelloy®) walls of the sample

chamber. The entire transmitter is temperature-controlled,

and the thermistors are heated to an elevated temperature

in a constant-current Wheatstone bridge. The thermistors

lose heat to the walls of the sample chamber at a rate that is

proportional to the thermal conductivity of the gas surrounding

them. Thus, each thermistor will reach a different equilibrium

temperature. The temperature difference between the two

thermistors is detected in the Wheatstone bridge, and the

resulting bridge voltage is amplified and converted to a linear 4

to 20 mA output proportional to the concentration of one of the

constituents of the binary or pseudo binary gas mixture.

Baker Hughes XMTC Panametrics Thermal Conductivity Binary Gas Transmitter Applications

Applications

A thermal conductivity gas transmitter for use

in the following industries and applications:

Metals industry

H2 in N2 atmosphere in metal heat-treating furnaces

Electric power industry

H2 in cooling systems for generators

Petroleum industry

H2 in hydrocarbon streams

Chemical industry

• H2 in ammonia synthesis gas

• H2 in methanol synthesis gas

• H2 in chlorine plants

Methane industry

• CO2 in methane

Landfill/biogas industry

• CO2 in biogas

• CH4 in biogas

Gas production industry

Purity monitoring of argon, hydrogen, nitrogen and helium

Food Industry

CO2 in fermentation processes

Features

• Ultra-stable glass-coated thermistors

• Single or dual gas push-button calibration

• PC interface package for digital output

• Type IP66/4X construction

• ATEX, IECEx, FM and CSA certified for Zone I

and Division 1 hazardous areas

VersaMax IC200PNS002-AC PROFINET Scanner Modules

General Installation Requirements

This product is intended for use with the Product Sub Family system. Its components are considered open

equipment (having live electrical parts that may be accessible to users) and must be installed in an ultimate

enclosure that is manufactured to provide safety. As a minimum, the enclosure shall provide a degree of

protection against solid objects up to 12mm (e.g. fingers). This equates to a NEMA/UL Type 1 enclosure or an

IP20 rating (IEC60529) providing at least a pollution degree 2 environment.

Installation in Hazardous Areas

The following information is for products bearing the UL marking for Hazardous Locations or ATEX marking for

explosive atmospheres:

▪ EQUIPMENT LABELED WITH REFERENCE TO CLASS I, GROUPS A, B, C & D, DIV. 2 HAZARDOUS LOCATIONS IS

SUITABLE FOR USE IN CLASS I, DIVISION 2. GROUPS A, B, C, D OR NON-HAZARDOUS LOCATIONS ONLY

▪ Equipment labeled with  II 3 G is suitable for use in Group 2 Category 3 environments.

▪ WARNING – EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,

DIVISION 2;

▪ WARNING – EXPLOSION HAZARD – WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING

OR WIRING MODULES; AND

▪ WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED

OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.

▪  WARNING – EXPLOSION HAZARD – USB PORT IS ONLY FOR USE IN NONHAZARDOUS LOCATIONS, DO NOT

USE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS.

VersaMax IC200PNS001-AC PROFINET Scanner Modules Features

Features

• Supports redundant power supplies. Use of the second

power supply is optional.

• Supports “hot swap” of a redundant power supply that is de-energized.

• Standard PROFINET alarm and diagnostics reporting.

• Supports configuration using Classless InterDomain

Routing (CIDR) with subnetting and supernetting.

• Each network interface module can be connected into a

daisy-chain/line, star, or ring (redundant media) topology.

• Supports Media Redundancy Protocol (MRP) client mode operation.

• Can be upgraded in the field; supports firmware updates via USB port.

• Provides Maintenance Mode to allow servicing of the

remote node while maintaining network connections.

(Requires firmware version 1.10 or later.)

• Supports Hot-Standby CPU Redundancy using

PROFINET I/O. If the PNS loses communications with

the Primary IO-Controller, it switches to the Secondary

IO-Controller. (Requires firmware version 2.00 or later)

Note: The USB port is for firmware upgrades only. It

is not intended for permanent connection

VersaMax IC200PNS001-AC PROFINET Scanner Modules

The VersaMax* PROFINET Scanner (PNS) module interfaces a remote node of VersaMax modules to a PROFINET

IO-Controller. The PROFINET Scanner scans the modules in its node, retrieving input data and providing output data,

and publishes input data on the PROFINET Network at the configured production rate. The PNS manages PROFINET

communication and module configuration between an IO-Controller and modules within the remote node. If network

communications are lost, the PNS manages I/O states according to the individual module configurations.

The PNS is available in two versions to allow you to use the network media that meet the requirements of your application.

IC200PNS001: Two 10/100 Mbps copper interfaces

IC200PNS002: Two 100Mbps Multi-Mode fiber (MMF) ports


The PNS module’s main Remote IO functions include:

• Scanning all the modules within its stick (input and output scan).

• Publishing data onto the PROFINET network to an IO-Controller at a customer-specified production period.

• Receive data from an IO-Controller on the PROFINET network at a customer-specified production period.

• Managing PROFINET communication and module configuration between an IO-Controller and modules within the PNS node.

• Managing the state of the I/O when communications is lost

• Publishing fault information (alarms, diagnostics, etc.) to IO-Controller

IC670MDL644 24VDC Pos/Neg Logic Fast Input 16 Pt. Grouped Host Interface

Host Interface

Intelligent processing for this module is performed by the Bus Interface Unit or elsewhere in

the system. This includes configuring features such as input defaults and fault reporting. The

module has 16 bits (two bytes) of discrete input data. A Bus Interface Unit is required to

provide this input data to the host and/or local processor.

Module Operation

A network of resistors and capacitors establishes input thresholds and provides input filtering.

Optoisolators provide isolation between the field inputs and the module’s logic components.

Data from all 16 inputs is placed into a data buffer. The module’s circuit LEDs show the

current states of the 16 inputs in this data buffer.

Parallel±to±seri al converters change input data from the data buffer into the serial format

needed by the Bus Interface Unit.

After checking the Board ID and verifying that the module is receiving appropriate logic power

from the Bus Interface Unit (which is reflected by the state of the module’s Power LED), the Bus

Interface Module then reads the filtered, converted input data.

IC670MDL644 24VDC Pos/Neg Logic Fast Input 16 Pt. Grouped LEDs

The 24 VDC Positive/Negative Fast Input Module (IC670MDL644) provides a single group of

16 discrete inputs, which may be driven by positive or negative logic.

Power Sources

The module receives power from the Bus Interface Unit to run its own 5±volt logic. An

external 24VDC supply is needed to power the input devices.

LEDs

Individual LEDs (logic side), visible through the transparent portion of the module top,

indicate the on/off status of each input. The PWR LED is on when field and backplane power

are present.
Positive or Negative Inputs

Inputs for this module can be either positive or negative inputs (all 16 inputs must be the same

type). Both types of signal produce a logic 1 (true) when the switch is closed. Selection of

positive or negative operation is made by the manner in which the external power supply is

connected to the inputs and to the I/O Terminal Block.

Positive inputs receive current from input devices and supply current to the common or negative

power bus. Input devices are connected between the positive power bus and the input terminals.

Negative inputs provide current to input devices and accept current from the common or

positive power bus. Input devices are connected between the negative power bus and the input

terminal.

HE693RTD600 Resistance Temperature Device Input Module

Product Description  

The RTD Input Modules allow RTD temperature sensors to be directly connected to the PLC 

without external signal processing (transducers, transmitters, etc.).  All analog and digital processing of 

the RTD signal is performed on the module, and temperature values in 0.5°C or 0.5°F increments 

(RTD600) or 0.125°C, 0.1°C or 0.1°F (RTD601) increments are written to the 90-30 %AI input table.  All 

modules feature six channels, and support PT-90 (MIL-7990); PT-100E, PT-100C, and PT-100Z; Ni-120, 

Cu-10, Cu-50, Cu-53, Cu-100, Pt-1000, TD5R and Linear Resistance. 

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Horner APG, LLC, Inc. (“HE”) warrants to the original purchaser that the Resistance Temperature Device

Input module manufactured by HE is free from defects in material and workmanship under normal use

and service.  The obligation of HE under this warranty shall be limited to the repair or exchange of any

part or parts which may prove defective under normal use and service within two (2) years from the date

of manufacture or eighteen (18) months from the date of installation by the original purchaser whichever

occurs first, such defect to be disclosed to the satisfaction of HE after examination by HE of the allegedly

defective part or parts. 

ALSOTOM V4561983-0100 circuit board control card module

V4561983-0100 ALSOTOM circuit board control card module

The V4561983-0100 circuit board control module is a high-performance circuit board core control

component with stable and reliable performance, high efficiency, low power consumption and easy installation and operation.

The module can realize data processing, logic control, signal conversion and other functions,

usually with a variety of different input and output interfaces, can be selected according to the actual needs.

In the field of industrial automation, the V4561983-0100 circuit board control card module

can be widely used in a variety of equipment and systems requiring precise control and stable operation.

For example, it can be used to control servo motors, stepper motors and other actuators

to achieve accurate position control and speed control;

At the same time, it can also be used for data acquisition and signal processing,

converting signals from sensors and other equipment into digital signals that can be processed,

providing strong support for automatic control and intelligent management of equipment.

In addition, the V4561983-0100 circuit board control card module also has the characteristics of strong anti-interference ability,

adapt to various harsh working environments, and can work stably in high temperature,

high humidity, high noise and other harsh environments.

In short, the V4561983-0100 circuit board control module is a powerful,

stable and easy-to-use circuit board control component that provides reliable support for

the control and management of equipment and systems in the field of industrial automation.