Meggitt C329635 Gas metering valve

Meggitt’s two-inch right angle style gas metering valve is in use on a variety

of aero-derivative gas turbines. With millions of field operating hours, this

design continues to prove the high reliability of Meggitt EMA technology.

Key features

• Exceptional accuracy,1% of flow point

• High speed brushless DCservo motor performance,20 Hz frequency response

• Less than 400 msec fullstroke response time

• Used on both DLE andSAC turbine engines

• Explosion proof design,CSA/UL certified for NECclass 1. division 1. groups C and D,

temp code T4.CE EExd NB, T4. CE-ATEXand PED certified

• All stainless steel valveand yoke materials forNACE compliance

• No maintenance requiredunder normal conditions

Specifications

Function: Precision fuel gas metering for aero-derivative, small and large frame turbine

engine control

Physical size:  5.56″ wide, 10.30″ high, 28.72″ long

Weight:  95 pounds

Flange type:  2″ ANSI B16.5 CL 300 raised face flanges

Line pressure:  0 to 700 psia

Fluid temperature:  –40 to 300°F

Ambient temperature:  –65 to 220°F

Performance:

Internal leakage:  ANSI class IV

Operating time:  Less than 400 msec full stroke response, 300 msec failsafe closed

Electrical:

Motor:  Steady state, 90 to 140 VDC, 0.30 ampere; 7.0 amperes maximum peak

Resolver:  4 VAC, 25 to 60 ma maximum

LVDT:  Excitation, 7.07 (±0.14) volts rms, 3000 (±300) Hz

Thermostat:  Opens at 329 to 347EF; resets at 251 to 270EF

Variations:  Outlet orientation direction optional, flow ranges from 80 to 22.000 pph

Meggitt VibroSmart ® VSI010 + VSB010 VibroSmart distributed monitoring system

VibroSmart distributed monitoring system

A VibroSmart ® distributed monitoring system

(DMS) is a network of small and economical

modules providing measurement,

communications or other functions that are

connected together in distributed, networked

measurement blocks in order to provide the

functionality normally offered by rack-based

machinery monitoring systems. A VibroSmart

system consists of one or more measurement

blocks, each containing up to sixteen VibroSmart

modules, a power supply and an optional host

computer running the VibroSight software.

A measurement block is a logical grouping of

VibroSmart modules that allows data such as

tachometer, trigger and alarm information to be

shared, for example, in order to monitor the same

machine. Measurement blocks are configured

using the VibroSight software.

Note: A VibroSmart system is limited to a

maximum of two VSI010 modules per

measurement block.

A VibroSmart module consists of an electronics

module (providing configurable machinery

monitoring functions) that clips into a VibroSmart

terminal base, which mounts on a DIN rail. A

range of plug-in fieldbus communications

adaptors that interface directly with the VSI010

module are available to provide an integrated

solution for interfacing to fieldbuses.

VibroSmart terminal bases incorporate buses and

connectors to provide all of the I/O connections

required to interface to a VibroSmart module.

Terminal bases also include non-volatile memory

to store the configuration of the attached

VibroSmart module, which allows modules to be

hot-swapped. Modules and terminal bases use

mechanical key-coding for a system that is simple

to operate and use.

Different VibroSmart modules, terminal bases and

fieldbus communications adaptors can be

combined to offer unique combinations of

functionality, versatility and safety assurance. In

this way, a monitoring system can be built to meet

the exact needs of an application resulting in a

more cost-effective and reliable solution.

Meggitt VibroSmart ® VSI010 + VSB010 communications interface module

Introduction

The VibroSmart ® distributed monitoring system

(DMS) is a system of modular and scalable

products designed for condition monitoring and

machinery protection applications for power

generation turbines, oil and gas applications and

auxiliary balance-of-plant equipment.

VibroSmart ® modules can be mounted directly

on machinery, reducing the need for expensive

cabling, because they are designed and certified

to work in extremes, such as harsh industrial

environments characterised by potentially

explosive atmospheres (Ex Zone 2), high

temperatures (70 °C, 158 °F) and high mechanical

stress. VibroSmart complements the VM600 series

of rack-based solutions from Meggitt’s

vibro-meter ® product line and is compatible with

the same VibroSight ® machinery monitoring

system software.

The VibroSmart ® VSI010 communications

interface module is an optional communications

module for use with other VibroSmart modules in a

monitoring system. The VSI010 module supports up

to two fieldbus channels and allows the data from

the VibroSmart modules in a measurement block

to be read by fieldbus master devices.

Meggitt VibroSmart ® VSI010 + VSB010 KEY FEATURES AND BENEFITS

KEY FEATURES AND BENEFITS

• VibroSight ® compatible hardware from the

vibro-meter ® product line

• Communications interfaces for industry

standard fieldbuses: Modbus RTU,

Modbus TCP, PROFIBUS DP and

GOOSE (IEC 61850)

• PROFIsafe safety layer to ensure more reliable

and secure PROFIBUS DP communications

• Two VSI010 modules per VibroSmart

measurement block allows redundant operation

• AND, OR and majority voting logic functions

for the combination of alarm and status

information for a VibroSmart measurement block

• VibroSmart ® security (module lock)

• Redundant communications and redundant

power supply inputs to improve availability

• Discrete outputs: 2 local relays

• Real-time Ethernet communications

• Live insertion and removal of modules (hot

swappable) with automatic reconfiguration

• Fully software configurable

• Robust enclosures with DIN rail mounting

APPLICATIONS

• Communications bridge between a

VibroSmart system and third-party systems,

such as a DCS or PLC

• Machinery protection and/or

condition monitoring

• Conforms to IEC 61850-3 requirements for

power plant and utility applications

Johnson Controls 4007ES IDNet 2 addressable device control

IDNet 2 addressable device control

The 4007ES Hybrid provides an IDNet 2 addressable initiating device

signaling line circuit (SLC) that supervises wiring connections and

the individual device communications status on the SLC. With 2

wire IDNet 2 SLCs, initiation, monitoring, and control devices such as

manual fire alarm stations, TrueAlarm sensors, control relays, and

sprinkler waterflow switches can communicate their identity and

status and receive fire alarm system control. Additional addressable

interface modules include circuit isolators, conventional IDC zone

adapters, and interface to other system circuits such as fans,

dampers, and elevator controls.

IDNet 2 addressable device operation

Each addressable device on the IDNet 2 communication channel

is continuously interrogated for status condition such as: normal,

off-normal, alarm, supervisory, or trouble. Both Class B and

Class A operation is available. Sophisticated poll and response

communication techniques ensure supervision integrity and enables

T-tapping of the circuits for Class B operation. Devices with LEDs

pulse the LED to indicate receipt of a communications poll and can

be turned on steady from the panel. With addressable devices,

the location and status of the connected device is monitored,

logged, and displayed on the operator interface LCD. For precise

identification, each device has its own 40-character custom label.

Johnson Controls 4007ES Hybrid, Fire Detection and Control Unit

Mechanical description

• Locking door with polycarbonate window.

• Latching front panel assembly swings forward for convenient

internal access.

• Smooth box surfaces are provided for locally cutting conduit

entrance holes exactly where required.

• Modules are power-limited except as noted, such as relay

modules.

• The battery compartment at the bottom, has space for two

batteries, up to 18 Ah. You can mount batteries within the cabinet

without interfering with module space. Charger capacity is up to

33 Ah. For information about batteries greater than 18 Ah and

external battery cabinets, see Module and accessories selection

information.

• Cabinet assembly design has been seismic tested and is certified

to IBC and CBC standards also to ASCE 7 categories A through

F, requires battery brackets. For more information, refer to data

sheet S2081-0019.

• Seismically compliant under the State of California Statewide

Office of Housing and Development (OSHPD) Special Seismic

Certification (SSC) program guidelines. Refer to Simplex Seismic

Application Guide 579-1213 and Battery Brackets for Seismic Activity

Applications S2081-0019 for details.

Johnson Controls 4007ES Series Convenient status information

Operator interface

Convenient status information

If the locking door is closed, through the glass window, you can view

the display status of the LEDs. The user interface is a 4.3 in. (109

mm) diagonal color touchscreen LCD with separate status LEDs. See

Figure 2.

LED indicators describe the general category of activity displayed and

the LCD provides more detail. Authorized users can unlock the door

to gain access to the control functions and scroll through the display

for additional detail.

Operator interface and software features

• Convenient and detailed operator information is easily accessible

using a logical, menu-driven touchscreen display with password

access control

• Multiple automatic and manual diagnostics for maintenance

reduction

• Alarm and Trouble History Logs, up to 1000 entries for each, 2000

total events. You can view these events from the display or print

them out on connected printer, or download them to a service

computer.

• Module level ground fault searching assists installation and

service by locating and isolating modules with grounded wiring

• WALKTEST silent or audible system test performs an automatic

self-resetting test cycle and supports up to eight WALKTEST

groups

• Install Mode can group multiple troubles for uninstalled modules

and devices into a single trouble condition, typical with future

phased expansion. With future equipment and devices grouped

into a single trouble, operators can clearly identify events from

the commissioned and occupied areas.

Johnson Controls 4007ES Series Fire Detection and Control Units

Introduction

4007ES Series Fire Detection and Control Units provide extensive

installation, operator, and service features with point and module

capacities suitable for a wide range of system applications. You can

configure Panels for stand alone or networked fire control operation.

The convenient and intuitive color touchscreen provides easy access

for typical system response actions and for detailed system review or

configuration updates with password control to limit user access.

Standard conventional IDCs and addressable IDNet 2

communications provide flexibility for both new and retrofit systems.

For IDC and NAC, you can select EOL resistor values to match a wide

range of existing initiating device circuits and notification appliance

circuits.

ES panel compatibility with ES Net

Simplex ES Network (ES Net) is a next generation IP-based fire

network that uses industry standard network technology and

infrastructure, and facilitates simplified network upgrades, easy

terminal connectivity and IP file transfer between nodes, and

advanced network diagnostics.

You can upgrade ES fire alarm control units (FACUs) to operate on an

ES network by adding an ES Net NIC to the panel.

To upgrade an existing 4120 network to ES Net, you must replace all

of the 4120 NIC cards on the network loop with ES Net NICs.

Note: ES Net NICs and 4120 NICs cannot be mixed on the same

network loop.

For more detailed information about ES Net, refer to data sheet

S4100-0076. and talk to your local Simplex product supplier.

Johnson Controls 4007ES Optional modules and connections include

Software feature summary:

• Current and previous panel configuration is maintained in on

board memory

• An internal Ethernet service port is available for service computer

connections to perform configuration updates, downloads and

uploads, report downloads, and update system software

• You can use the internal USB interface with a memory stick to

store job revisions, update revised jobs and panel software, and

save detailed system reports from the panel.

Optional modules and connections include:

• Fire alarm network interface card (NIC) for ES Net or 4120 network

• Peer-to-peer network communications, supports either Class B or

Class X operation

• Point or Event DACT assembly for Connected Services Gateway

• Up to two additional IDNet 2 addressable device output loop

connections with short circuit fault protection and with 75

additional point capacity each.

• Front mounted 32 LED and 32 LED/switch annunciator with

custom label inserts. LEDs are programmable for up to 32

IDC zones of alarm and trouble annunciation or other custom

annunciation requirements.

• Remote LED annunciator support through remote user interface

(RUI) communications port for use with UTP wiring.

• Dual RS-232 ports for printer, PC annunciator, or third party interface.

• Alarm relays and auxiliary relays.

• City connections, with or without a disconnect switch.

• 4009 IDNet NAC Extenders to extend NAC capability for power and

distance

• Battery brackets for seismic area protection. 

Johnson Controls 4007ES Electrically isolated IDNet 2 addressable initiating device SLC

Electrically isolated IDNet 2 addressable initiating device SLC:

• Provides built-in short circuit isolation for monitoring and

control of TrueAlarm analog sensors and IDNet communications

monitoring and control devices. For use with either shielded or

unshielded, twisted or untwisted single pair wiring. Outputs are

Class A or Class B.

• Standard panel signaling line circuit (SLC) provides up to 100

addressable points. Optional additional loop expansion modules

provide an additional isolated loop with short circuit isolation for

the IDNet 2 channel. Each loop expansion module also provides

an additional 75 addressable points.

Power supply:

• Four notification appliance circuits (NACs), you can select as Class

A or Class B with 6 A total available current

• You can select the NAC EOL resistor value from a wide range of

resistance values for retrofit convenience

• For additional notification power capacity, use a 4009 IDNet NAC

Extender.

• Battery backup charging of up to 33 Ah. Up to 18 Ah for cabinet

mounted batteries and up to 33 Ah for batteries mounted close

nippled, in a remote battery cabinet.

General mechanical:

• Red or platinum cabinet. Rated NEMA 1 and IP30.

4007ES Listings reference:

• UL 864 – Control Units, System (UOJZ). Control Unit Accessories,

System, Fire Alarm (UOXX). Control Units, Releasing Device Service

(SYZV)

• UL 2017 – Emergency Alarm System Control Units (CO detection),

(FSZI)

• ULC-S559 – Central Station Fire Alarm System Units (DAYRC)

• ULC-S527 – Control Units, System, Fire Alarm (UOJZC). Control Unit

Accessories, System, Fire Alarm (UOXXC). Control Units, Releasing

Device Service (SYZVC)