Accuracy
•Amplitude : ≤ 1% of input FSD (measurement bandwidth from 10 Hz to 1 kHz)
•Phase : ≤ 1.5 ° (measurement bandwidth from 10 Hz to 1 kHz)
Signal to noise ration (SNR) : ≥ 80 dB (measurement bandwidth from 10 Hz to 2 kHz)
Common-mode voltage (CMV) range : ± 5 V
Common-mode rejection ratio (CMRR) :> 60 dB (at 50 / 60 Hz)
Crosstalk attenuation : Typically 60 dB
Auxiliary input channel – used as a tachometer input
Triggering method :Crossing of threshold on rising edge of signal
Triggering threshold (rising edge) : 2/3 of peak-peak value
Voltage range : ± 30 VRMS / ± 42.4 VAC ( PEAK ) or 60 VDC
Leave a comment