Every TQMC701 is factory calibrated. The calibration

information is stored in a user-accessible on-board serial

EEPROM individual to every module. The correction data

values may be used to perform a hardware correction for

A/D channels per input range and D/A channels per output

range during functional operation.

In addition, there is a temperature sensor on every module

to allow supervisory and data temperature coherence

evaluation.

The TQMC701 provides different operation modes to

perform manual and automatic A/D and D/A conversions.

For automatic conversions there are dedicated A/D and

D/A sequencer units. These include on-board data buffer

and DMA controller for A/D data transfer, D/A data fetch

and conversion rate generators.

Sequencers provide optionally a Frame Mode for repetitive

frames of A/D and D/A conversions upon an internal or

external trigger signal event.

Conversion clock (conversion rate) and frame trigger

signals may be generated on-board for internal use.

Optionally these can be provided via the I/O connector if

the card is operating as a master card in a Multi-Board

configuration (externally synchronization). The conversion

clock (conversion rate) and frame trigger signals may also

be sourced externally to be used internally.

The TQMC701 is available as air cooled and conduction

cooled variant.