Measuring range

Range: Continuously adjustable via configuration software

Vrms (metric) = 5 – 100 mm/s (±25 to ±500 µm)

Vrms (Imperial) = 0.197 in/sec to 3.937 in/sec (±0.984 mils to ±19.685 mils)

Frequency range: 10 – 1000 Hz (VDI 2056. DIN 4566. ISO 3945)

Selectable frequency ranges: 5 – 50 Hz, 10 – 50 Hz, 50 – 1000 Hz, or 50 – 1600 Hz

Lift coil current: 0 – 8 mA, adjustable in 40 μA steps

Lift coil current accuracy: ±0.5% of full scale range, ±0.5% of set value

Maximum allowable load: 3.4 kΩ at 2 mA

Minimum dynamic input voltage: 311 mV peak to peak

Maximum dynamic input voltage: 9500 mV peak to peak

Sensor power supply:

Individually buffered sensor power supply

Galvanically isolated from all system voltages and system supply voltages.

Protected against open and short circuits