Specifications
Sensor by Range and Frequency Response Vibration Overall (Z): 80 g’s, 20.000 Hz;
PeakVue Z – 80 g’s, sampling 51.2 kHz Vibration Overall (X): 16g’s, 1000 Hz;
Vibration Overall (Y): – 16 g’s, 1000 Hz Temperature -40°C to +85°C
Analysis Parameters 2 velocity bands (defaults 2-65 Hz and 65-300 Hz) and
2 acceleration bands (defaults 10-500 Hz and 500-1000 Hz)
Prescriptive Analytics Bearing/Mechanical and Lubrication Severity;
Calculated Machine Speed (RPM)
Waveform and Spectrum Main axis (Z): User selectable FMax (200 Hz, 500 Hz,
1 kHz, 2 kHz, 5 kHz, 10kHz, 20kHz) User selectable FMin (2 Hz, 10 Hz);
User selectable resolution (400. 800. 1600 LOR)
Secondary Axes (X and Y): User selectable FMax (200 Hz, 500 Hz, and 1000 Hz)
Diagnostic Thumbnail Spectra Velocity and PeakVue based on 1600 LOR
Operating Temperature -40° to +85°C
Operating Humidity 95%, non-condensing
Wireless Protocol IEC 62591 WirelessHART®
Broadcast Range 100m Line of Sight
Hazardous Location Certifications Check documentation below for certificates
General Certifications Check data sheet for more details
Leave a comment