Specifications

Sensor by Range and Frequency Response Vibration Overall (Z): 80 g’s, 20.000 Hz;

PeakVue Z – 80 g’s, sampling 51.2 kHz Vibration Overall (X): 16g’s, 1000 Hz;

Vibration Overall (Y): – 16 g’s, 1000 Hz Temperature -40°C to +85°C

Analysis Parameters 2 velocity bands (defaults 2-65 Hz and 65-300 Hz) and

2 acceleration bands (defaults 10-500 Hz and 500-1000 Hz)

Prescriptive Analytics Bearing/Mechanical and Lubrication Severity; 

Calculated Machine Speed (RPM)

Waveform and Spectrum Main axis (Z): User selectable FMax (200 Hz, 500 Hz, 

1 kHz, 2 kHz, 5 kHz, 10kHz, 20kHz) User selectable FMin (2 Hz, 10 Hz); 

User selectable resolution (400. 800. 1600 LOR)

Secondary Axes (X and Y): User selectable FMax (200 Hz, 500 Hz, and 1000 Hz)

Diagnostic Thumbnail Spectra Velocity and PeakVue based on 1600 LOR

Operating Temperature -40° to +85°C

Operating Humidity 95%, non-condensing

Wireless Protocol IEC 62591 WirelessHART®

Broadcast Range 100m Line of Sight

Hazardous Location Certifications Check documentation below for certificates

General Certifications Check data sheet for more details