Overview of functions

• PID controllers

• Integrated display and operating elements.

With MFD-CP8…/CP10… you can create solutions for domestic applications

as well as for tasks in machinery and plant construction. MFD-CP8…/CP10…

is a modular and flexible device.

The integrated easyNet network makes it possible to connect up to eight

NET stations to a PLC. All devices with a NET terminal connection can be

used as NET stations. At present these devices consist of easy800/MFD

CP8…/CP10…, easySafety devices or type XC200/EC4-200 PLCs.

Each Net station can process its own circuit diagram and a visualization

application. This allows the design of systems using high-speed controllers

with decentralized intelligence.

Each Net station can process its own circuit diagram and a visualization

application. This allows the design of systems using high-speed controllers

with decentralized intelligence.

With easy you can create a circuit diagram in ladder diagram. The circuit

diagram entry can be carried out directly on the device using the operator

buttons or on your PC using the easySoft-Pro programming software.

For example, you can:

• Connect N/O and N/C contacts in series and in parallel

• Connect output relays and markers.

• Define outputs as coils, impulse relays, rising or falling edge-triggered

relays or as latching relays.