2600T Series Pressure Transmitters Engineered solutions for all applications

Base accuracy

0.04 % of calibrated span, (Option 0.025 %)

Reliable sensing system coupled with very latest digital

technologies

provides large turn down ratio up to 100:1

Comprehensive sensor choice

optimize in-use total performance and stability

10-year stability

0.15 % of URL

Flexible configuration facilities

provided locally via local LCD keypad

New TTG (Through-The-Glass) keypad technology

allows quick and easy local configuration without opening the

cover, even in explosion proof environments

IEC 61508 certification

for SIL2 (1oo1) and SIL3 (1oo2) applications

Full compliance with PED Category III

Span limits

Maximum span = URL

IT IS RECOMMENDED TO SELECT THE TRANSMITTER

SENSOR CODE PROVIDING THE TURNDOWN VALUE AS

LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE

CHARACTERISTICS.

Zero suppression and elevation

Zero and span can be adjusted to any value within the range

limits detailed in the table as long as: – calibrated span ≥ minimum span

Damping

Selectable time constant between 0 and 60 s

This is in addition to sensor response time

Turn on time

Operation within specification in less than 10 s with minimum

damping.

Insulation resistance

> 100 MΩ at 500 V DC (terminals to earth)