Measurement made easy

Robust and reliable glass tube variable area flowmeter

Function

• Glass tube variable area flowmeter for the measurement

of clear liquids and gases

Areas of application

• Suited for flow measurements in many industrial sectors

such as apparatus engineering, the food and beverage

industry, water treatment systems and the chemicals sector

Product highlights

• Precision tubes with guide surfaces, guide ribs or guiderod

• Standard stainless steel housing

• Easy disassembly of the meter tube due to the O-ring seal

• Meter tube and float can be replaced independently of each other

Important product features

• A magnetically actuated alarm signaling unit size ½ in and

up can be attached to the flowmeter

Functional description

The VA Master FGM1190 series flowmeters work according to

the float principle.

The position of the float in the conical glass meter tube is

proportional to the flow. It can be read on the scale fitted to

the meter tube.

Four different types of scale can be used:

• Directly readable scale in flow units

• Percentage scale

• DK/DS scale

• Millimeter scale

When using the DK/DS scale a flow rate table is available for

the flowmeter. For other operating conditions, the user can

create additional tables.

Flowmeters in sizes ½ in to 2 in are provided with a

percentage scale in the standard design. The device has a

factory plate indicating the flow rate for the display of 100 %.

The other scale values can be linearly converted. A special

reading curve is therefore not required.

On request, conversion equations for flow calculation for

other operating conditions will be made available.