Airflow Sensors

AWM90000 Series microbridge mass airflow sensors are available in two versions,

mass flow and differential pressure. The AWM92100V has a flow range of ±200

SCCM with a pressure drop of only 0.49 mbar | 49 Pa | 0.007 psi, typically.

The AWM92200V is a differential pressure version that has a range of ±2 inH2O.

The AWM90000 Series sensors have a 1 ms response time, operate with a supply

voltage from 8.0 Vdc to 15.0 Vdc, while consuming only 50 mW of power.

The compact plastic package will withstand a maximum overpressure of 1720

mbar | 72 kPa | 25 psi without compromising performance. The sensor is well

suited for use in portable devices and battery powered applications.

The AWM90000 Series provides customers with a combination of time-proven

reliability, repeatable flow sensing, and the ability to customize the sensor

functions to meet their specific application needs.