Typical Applications

• Foodservice equipment

• Industrial machinery

• Medical equipment

• Packaging equipment

• Plastics processing equipment

Specifications

Controller

• Microprocessor based, limit controller

• Customer defined hysteresis, model number

dependent

• High limit, factory selectable

• Automatic reset on power loss

• Input filter time: 1 second

Thermocouple Sensor Input

• Ungrounded

• Type J and K thermocouple types

• >10 MΩ input impedance

Input Accuracy Span Range

• Type J: 0 to 764°F (-18 to 406°C)

• Type K: 0 to 999°F (-18 to 537°C)

• Calibration accuracy: ±6°C, ±1° at standard conditions

and actual calibration ambient

• Temperature stability: ±0.3 degree per degree change

in ambient

Allowable Operating Ranges

• Type J: 32 to 626°F (0 to 330°C)

• Type K: 32 to 820°F (0 to 438°C)

Output Types

• Electromechanical relay, Form A, minimum load

current: 100mA, 8A resistive load, 120VA pilot duty,

120/240VAC maximum, inductive, electrical life 6,000

cycles at rated current

Terminals

• 0.25 in. (6.4 mm) quick connect, push-on terminals

Agency Approvals

• UL® / EN 60730-1, 2, 9 automatic electronic controls

for household and similar use. File #E43684

• UL® 1998 software review class B

• W.E.E.E.; CE – see Declaration of Conformity

• RoHS directive (2011-65-EU)

Power

• 100-240VAC +10%; -15%; 50/60Hz, ±5%

• 10VA maximum power consumption

• Data retention upon power failure via nonvolatile

memory

Environment

• Operating temperature: 32 to 158°F (0 to 70°C)

• Storage temperature: -40 to 185°F (-40 to 85°C)

• Relative humidity: 0 to 90% RH, non-condensing