The ibaLink-VME card can be used in both VME32 and VME64 systems (6U height).

5 V power supply is required (from VMEbus).

VME specification according to ANSI VITA 1-1994:

■ Supported addressing modes: A24. A32. A40 and A64

■ Supported data formats: 8/16/32 Bit (D08/D16/D32/MD32)

■ Supported block transfer modes: 8/16/32 Bit (BLT)

■ Supported block transfer modes: 64 Bit (MBLT)

■ Support for unaligned transfers (UAT) and read-modify-write (RMW)

The following modes are not supported:

■ Auto configuration (AutoSlotID)

■ 2eVME/2eSST

The ibaLink-VME card is a passive slave board on the VMEbus, i.e. no active master access on

the VMEbus will be performed. The card occupies 256 kByte memory space on the VMEbus.