The ibaLink-VME card can be used in both VME32 and VME64 systems (6U height).
5 V power supply is required (from VMEbus).
VME specification according to ANSI VITA 1-1994:
■ Supported addressing modes: A24. A32. A40 and A64
■ Supported data formats: 8/16/32 Bit (D08/D16/D32/MD32)
■ Supported block transfer modes: 8/16/32 Bit (BLT)
■ Supported block transfer modes: 64 Bit (MBLT)
■ Support for unaligned transfers (UAT) and read-modify-write (RMW)
The following modes are not supported:
■ Auto configuration (AutoSlotID)
■ 2eVME/2eSST
The ibaLink-VME card is a passive slave board on the VMEbus, i.e. no active master access on
the VMEbus will be performed. The card occupies 256 kByte memory space on the VMEbus.