Communication protocols
All current and former ibaNet communication protocols are supported. Thus, data from
an old ibaPADU device (S/N < 1000) as well as from an ibaPADU-S-IT of the new gen
eration can be processed by this card.
Furthermore, the ibaNet protocol 5 Mbit/s for fast data acquisition (25 kHz) over de
vices ibaPADU-8-ICP, ibaPADU-8-M or -16-M is supported.
The valid ibaNet protocol of the fiber optic input data stream is detected automatically
by the card. The 32Mbit Flex protocol is supported with firmware version V2.00 (build
172 (C2)) or higher.
Fast data processing with reduced CPU load
Due to the DMA technology (DMA = Direct Memory Access) measured data are written
directly into the computer’s memory which is used by the software application for read
ing the data. It is a significant relief for the CPU load while data traffic is boosted.
iba field devices
Following, you‘ll find a listing of some iba field devices which can be connected to the
ibaFOB-io-ExpressCard:
ibaPADU-8. -16. -32
ibaPADU-8-ICP, -8-M, -16-M
ibaPADU-S-IT
ibaDIG-40
ibaBM-DPM-S, -S-64 (Profibus DP)
ibaBM-eCAT
ibaBM-SiLink
ibaBM-SLM (SIMOLINK)
ibaBM-DDCS (DDCS Drive Bus)
ibaBM-COL-8i-o
ibaBM-DIS-i-8o
ibaBM-FOX-i-3o-D
ibaNet750-BM
ibaPACO-4
ibaLink-SM-64-i-o
ibaLink-SM-64-SD16
ibaLink-SM-128V-i-2o
Leave a comment