DIN-rail mounting

The Megablocks are designed for mounting on 35mm x 7.5mm T-section “top hat”

DIN rail to EN50022 and use built-in DIN rail clips to attach to the rail.

Mounting procedure

Megablocks are attached to the DIN rail using a “push-and-tilt” method – as illustrated

on the body label and in Figure 4.1 below.

Tilt the Megablock towards the trunk-connector side of the Megablock and then

engage the DIN-rail clips under the ledge of the DIN rail. Push the Megablock against

the edge of the rail then rotate the Megablock until it sits flat onto the DIN rail, then

release the pressure to allow the clips on the other side to engage.

Removal from DIN-rail

Refering to Figure 4.1. push the Megablock against the edge of the DIN rail, tilt the

other side of the Megablock up and away from the DIN rail, then release the side

pressure to disengage the DIN rail clips from the DIN rail ledge.