Key Features

• Outstanding drilling rates are made possible by significantly

reduced step response times

• New motor design with improved thermal management

• Lightweight beryllium mirrors

• Digital dynAXISse

encoder technology

• Automatic jump delay setting for all jump lengths (1)

Typical Applications

• PCB industry

• Via hole drilling

• High density interconnects (HDI)

Specifications

Aperture 20 mm

Maximum scan angle(2) ± 0.349 rad

Wavelength(3) 9400 nm

Step response

(positioning and settling to ±5 μm at

100 mm focal length)

0.13 ms at 0.2 mm

0.22 ms at 0.5 mm

0.29 ms at 1 mm

Temperature drift(2) Offset: < 10 μrad / K

Gain: < 5 ppm / K

Long-term drift(2)

(8-hour-Drift after 30 min warm-up,

at constant ambient temperature and load)

Offset: < 50 μrad

Gain: < 50 ppm

Power supply requirements 48 V, 3 A (RMS)

Water cooling requirements 3 l / min at 20 °C and

Δp < 1 bar, p < 4 bar

(1) RTC6 control board required

(2) all angles are optical angles

(3) others on request