Mounting and Removing the Modules

To mount and remove the modules, the connection cable clamp terminals must be

unplugged.

Additionally, personnel must be protected from electrostatic discharge. For details, refer to

Chapter 2.1.2.

Mounting the Modules

To mount a module into the rack

1. Insert the module as far as it can go – without jamming it – into the two guiding rails

which are located on the upper and lower part of the enclosure.

2. Apply pressure to the upper and lower extremity of the front plate until the module plugs

snap into the backplane socket.

3. Secure the module with the screws located on upper and lower extremity of the front

plate.

The module is mounted.

Removing the Modules

To remove a module from the rack

1. Remove the plugs from the module front plate.

2. Release the locking screws located on the upper and lower extremity of the front plate.

3 Loosen the module using the handle located on the lower part of the front plate and

remove it from the guiding rails.

The module is removed.