How it works
Standard configuration
The Aalborg CHB design consists of a large furnace welded to vertical, plain-type convection
tubes with spiral inserts. The low-alloyed plate material is easy to weld and is highly durable
to prevent cracking. Aalborg CHB boilers have fully water-cooled furnaces and can be
equipped with various burner types. The boiler comes complete with connections, foundation,
inspection hatches, manhole, hand-holes, insulation with sheeting as well as all valves and fittings.
Other standard features include:
• Modulating boiler water regulation
• Burner type according to preference and the type of fuel used
• Alfa Laval Gas Valve Units (GVU) and Methanol valve units (MVU) for alternative fuels
• Processor-based control system
• Control panel with touchscreen interface for all necessary operation, communication,
safety and alarm functions
• Integrated water-washing device
• Spare parts according to classification society demands
Leave a comment