Working principles
The Alfa Laval Aalborg HPNC boiler is designed to operate
in a closed loop system, a so called thermo syphon system,
where circulation is ensured through gravity. The steam cycle
is completely sealed off to remove any risk of corrosion.
Steam generation is taking place in two concentrically
arranged coils – the inner coil which forms the furnace and
the outer coil which provides for convective heat transfer
through the second and third gas passes.
Depending on boiler size each coil can consist of one single
flow way or several parallel flow ways. This design ensures
sufficient and reliable circulation and thereby also cooling of
all the heat transfer parts of the boiler.
Standard equipment
As a standard the high pressure boiler is fitted with the required
accessories for a safe and reliable operation, including safety
valve, rupture disc assembly and low water level cut-off
electrodes.
Burner equipment includes pressure jet burner for fuel oil, gas
or a combination hereof as well as the required equipment for
fuel line system.
The boiler system can be filled with water using a vacuum
system or by using the optional high pressure filling pump.