Electric hybrid capability (option)

Besides serving as a fired boiler, the Aalborg OS-TCi can be

configured as a hybrid boiler, allowing it to operate on electrici

ty. This lets it utilize shore power or surplus electricity on board,

producing steam or hot water without direct emissions. It also

enhances the boiler’s turn-down ratio, which improves startup

time and reduces maintenance by enabling continuous

operation at lower loads.

The optional electric heater comprises one or two heating

elements, each 600 kW in capacity. To incorporate it, the

boiler interior must be modified. This has no impact on the

boiler’s high efficiency, but it may require small adjustments

in height or diameter.