Working principle
On applications where the pumped media contains a mixture of
air and liquid in the suction line, airscrew rotation causes the
formation of a continuous liquid ring within the canister. Due to the
eccentric position of the canister relative to the airscrew, an air
chamber forms between the liquid ring and the airscrew, which
separates into air pockets between the air-screw vanes.
The continuous rotation of the airscrew forces air pockets through
the canister into the suction stage of the impeller which are then
pumped out via the discharge.
Liquid is returned from the discharge via the recirculation pipe into
the canister to ensure the liquid ring is maintained at all times.
When there is no air present, the canister and recirculation loop
have no function and are fully filled with liquid. The liquid passes
through the canister into the suction stage of the impeller,
allowing the pump to act as a traditional centrifugal pump.