Routing High and Encoder Interface
The Ultra5000 main encoder feedback connector is CN2. The motor encoder
interface circuitry features include:
• 2.5 MHz maximum line frequency
• RS-485 serial channel for communicating with intelligent encoders
• Hall input for start-up commutation only
• Interpolation of sine/cosine encoders
All encoder signals are filtered using analog and digital filtering. The inputs
also include illegal state change detection. Refer to Figure 2.5 for a schematic
of the motor encoder inputs.
Hardware latches can be used for latching the encoder position based on an
index input or a digital input transition. Low Voltage Cables
Be aware that when you connect and route power and signal wiring on a
machine or system, radiated noise from nearby relays (relay coils should have
surge suppressors), transformers, and other electronic drives can be induced
into motor or encoder feedback, communications, or other sensitive, low
voltage signals. This can cause system faults and communication problems. To
minimize the levels of radiated noise, route machine power and signal lines
separately.