Description

The primary purpose of the Dynamic Input module is to digitize the sensor signal at

a rate that completely encompasses the signal content and provides transducer power for various

sensors.

The Orbit 60 Series Dynamic Input modules are a set of 4-channel input modules available

in both negative and positive dynamic input options. The inputs are also used for speed

or Keyphasor signals All dynamic input modules that support speed or Keyphasor signals

can be configured to have Primary and Backup Speed Source support,

to allow for speed redundancy functionality. 

The module supports backup speed source functionality.

When configured, if the primary speed source enters an invalid state,

a backup speed channel will be utilized to provide a speed reference for

configured synchronous measurements. Compensations for differences in shaft

speed and phase reference timings can be configured to maintain measurement

accuracy upon transitioning to backup speed sources.