DEIF MVR-M210 Available Extension Cards

Available Extension Cards:

– 8x digital inputs (programmable threshold voltage)

– 5x output relays

– Arc-Flash Protection – 4x sensor channels, 2x HSO1. 1x BI *)

– 8x RTD input

– 2x RJ45 100Mb Ethernet & IRIG-B *)

– 2x ST 100Mb Ethernet & IRIG-B *)

– 4x mA outputs – 1 x mA input

– 2x LC 100MB Ethernet (HSR, PRP redundant protocols)

– 2x RJ45 100MB Ethernet (HSR, PRP redundant protocols) *)

– RS-232 – Serial Fiber

*) Land based applications only. Not marine approved

Marine approvals

– DNV/GL

– Lloyds Registeres LR

– Bureau Vertias BR

– ABS (USA)

– CCS (China)

– CNK (Japan)

– IEC (Israel)

– KR (Korea)

– UKCA (UK)

– RINA (Italy)

DEIF MVR-M210 Motor Protection

The MVR-M210 is a compact motor protection and control solution which

can be extended by 4 available extension slots. The device can connect up

to 12 RTD sensors for thermal alarms and tripping.

5 x Current input (configurable 0.2…10A)

3 x Digital input

5 x Output relay (4NO, 1CO)

1 x IRF output (1CO)

2 x Remote com port (1 x RJ45 Ethernet and 1 x RS-485)

– IEC 61850 Ed1. Modbus TCP/RTU, IEC 60870-5-104/103/101. DNP

3.0. SPA protocols

– DT, IEC or ANSI time/overcurrent curves with settable release delays

– 4 extension slots for additional hardware options

– Event recorder (up to 15 000 events)

– Disturbance recorder (up to 100 disturbance records)

– supports 5 thermal models (time constant accurate)

– soft-start protection starts at 6Hz

– Wye-delta started motor supervision

– two-speed motor protection

DEIF LMR-122D Loss of mains relay

DEIF’s loss of mains relays protect generators against damage

resulting from a non-synchronised reconnection  to the grid

after a temporary mains failure.

A mains failure will be  detected, provided a disconnection at

an arbitrary point of the network results in a swift  change of

the generator frequency (vector shift). An  opening signal is

then transmitted to  the mains circuit breaker, and the generator

will thus be protected against  damages caused by an automatic

reconnection to the high-voltage network.

Variants

LMR-111D

• Vector shift

LMR-122D

• Vector shift and df/dt (ROCOF)

Features

• Vector shift and df/dt (ROCOF)

• Detection of vector shift

• ANSI code 78

• Mains disconnection on mains failure

• Ensures no asynchronous reconnection

• LED indication of fault condition

• LED indication for activated relay

• 35 mm DIN rail or base mounting

DEIF LMR-111D Loss of mains relay

DEIF’s loss of mains relays protect generators against damage resulting

from a non-synchronised reconnection to the grid after a temporary

mains failure.

A mains failure will be detected, provided a disconnection at an arbitrary

point of the network results in a swift change of the generator frequency

(vector shift). An opening signal is then transmitted to the mains circuit

breaker, and the generator will thus be protected against damages caused

by an automatic reconnection to the high-voltage network.

Variants

LMR-111D

•  Vector shift

LMR-122D

• Vector shift and df/dt (ROCOF)

Features

• Vector shift

• Detection of vector shift

• ANSI code 78

• Mains disconnection on mains failure

• Ensures no asynchronous reconnection

• LED indication of fault condition

• LED indication for activated relay

• 35 mm DIN rail or base mounting

DEIF APU-4 Advanced G59 and G99 protection unit

The APU-4 features all relevant protective functionalities integrated as standard

– simple and easy G59/3 and G99 compliance. The best and the latest check

synchronisation technology is available as an option.

All parameter settings are fully password protected to control access rights.

Featuring an alarm log of up to 150 events, you can analyse faults and prevent

them from reoccurring. Moreover, it automatically carries out a cyclical self-test.

If any errors are found an LED on the front panel and a status output will

indicate it.

With the complimentary PC software download, you can save parameters and

retrieve log data. The software also contains M-logic – a simple-to-use relay logic

compiler. This tool makes it possible for you to customise the application according

to your needs. It is possible to dedicate specific functions or logic conditions to

different in- and outputs.

The APU-4 also features an optional remote, mountable operator panel with a large

display for easy access and reading of values. Among the many reading options you

will find the following: busbar voltage, current, frequency and power factor.

You can attach the display to the basic unit inside the switchboard or mounted on

the front of the switchboard, according to preference.

The optional Modbus TCP/IP communications protocol allows for easy communication

and a number of readout possibilities: remote monitoring for value and alarm readings,

service technician alerts via e-mail or text message, various measurements, etc.

Features

• Complies with G59/3 and G99

• Includes free utility software – available for download

• Modbus TCP/IP communication

• User-friendly display for easy access and value readings

• Fully password protected

DEIF MVR-G257 Features Protection Functions

Features

Protection Functions:

• Sensitive) Earth fault protection stages INST, DT or IDMT (ANSI 50N/51N(S))

• 100% Stator Earth fault protection (ANSI 64F3)

• Auto-reclose (ANSI 79)

• Breaker failure protection (ANSI 50BF)

• Cable-end differential protection (ANSI 87)

• Current transformer supervision (ANSI 60L)

• Current unbalance/broken conductor protection stages INST, DT or IDMT (ANSI 46 /R/L)

• Directional (sensitive) residual over-current protection stages DT or IDMT (ANSI 67N)

• Directional three-phase over-current protection stages DT or IDMT (ANSI 67)

• Frequency protection stages (ANSI 81O/U)

• Fuse failure (ANSI 60)

• Harmonic over-current protection/inrush blocking stages INST, DT or IDMT (ANSI 50H/51H/68)

• Inadvertent energizing (ANSI 50/27)

• Loss of field (ANSI 40)

• Machine thermal overload protection (ANSI 49M)

• Motor or generator differential protection, 2-winding (ANSI 87M/G)

• Over-excitation protection (ANSI 24)

• Overvoltage protection INST, DT or IDMT (ANSI 59)

• Positive/negative sequence under-/over-voltage protection INST, DT or IDMT (ANSI 27P/47/59P)

• Power factor (ANSI 55)

• Programmable stage (ANSI 99)

• Rate of Change of Frequency ROCOF (ANSI 81R)

• Residual voltage protection INST, DT or IDMT (ANSI 59N)

• Restricted low-impedance earth fault protection (ANSI 87N)

• Reverse-/under-/over-power protection INDT, DT or IDMT (ANSI 32)

• Synchrocheck (ANSI 25)

• Three-phase over-current protection INST, DT or IDMT (ANSI 50/51)

• Under-impedance protection (ANSI 21)

• Under-voltage protection INST, DT or IDMT (ANSI 27)

• Vector jump/surge (ANSI 78)

• Voltage controlled/dependent over-current protection (ANSI 51V)

• Voltage memory

DEIF MVR-G257 Available Extension Cards

Available Extension Cards:

– 8x digital inputs (programmable threshold voltage)

– 5x output relays

– Arc-Flash Protection – 4x sensor channels, 2x HSO1. 1x BI *)

– 8x RTD input

– 2x RJ45 100Mb Ethernet & IRIG-B *)

– 2x ST 100Mb Ethernet & IRIG-B *)

– 4x mA outputs – 1 x mA input

– 2x LC 100MB Ethernet (HSR, PRP redundant protocols)

– 2x RJ45 100MB Ethernet (HSR, PRP redundant protocols) *)

– RS-232 – Serial Fiber

*) Land based applications only. Not marine approved

Marine approvals

– DNV/GL

– Lloyds Registeres LR

– Bureau Vertias BR

– ABS (USA)

– CCS (China)

– CNK (Japan)

– IEC (Israel)

– KR (Korea)

– UKCA (UK)

– RINA (Italy)

DEIF MVR-G257 Generator Differential Protection

The MVR-G257 is a generator differential protectionrelay for large or critical

synchronous generators. It provides voltage and current based protection

functions including differential protection and measurement of all vital values

to be supervised. Furthermore it can connect up to 16 RTD sensors for

thermal alarms and tripping. It comes with 9 avaialable extension slots to

extend the device with additional communication interfaces and I/Os.

10x Current input (configurable 0.2…10A)

4x Voltage input (1.00…480.00V (RMS)

3x Digital input

5x Output relay (4NO, 1CO)

1x IRF output (1CO)

2x Remote com port (1 x RJ45 Ethernet and 1 x RS-485)

– IEC 61850 Ed1. Modbus TCP/RTU, IEC 60870-5-104/103/101. DNP 3.0. SPA protocols

– DT, IEC or ANSI time/overcurrent curves with settable release delays

– 9 extension slots for additional hardware options

– Event recorder (up to 15 000 events)

– Disturbance recorder (up to 100 disturbance records)

– Measuring accuracy can be calibrated to Class 0.2

– Differential Protection

DEIF MVR-G215 Available Extension Cards

Available Extension Cards:

– 8x digital inputs (programmable threshold voltage)

– 5x output relays

– Arc-Flash Protection – 4x sensor channels, 2x HSO1. 1x BI *)

– 8x RTD input

– 2x RJ45 100Mb Ethernet & IRIG-B *)

– 2x ST 100Mb Ethernet & IRIG-B *)

– 4x mA outputs – 1 x mA input

– 2x LC 100MB Ethernet (HSR, PRP redundant protocols)

– 2x RJ45 100MB Ethernet (HSR, PRP redundant protocols) *)

– RS-232 – Serial Fiber

*) Land based applications only. Not marine approved

Marine approvals

– DNV/GL

– Lloyds Registeres LR

– Bureau Vertias BR

– ABS (USA)

– CCS (China)

– CNK (Japan)

– IEC (Israel)

– KR (Korea)

– UKCA (UK)

– RINA (Italy)

DEIF MVR-G215 Generator Protection

The MVR-G215 generator protection relay is a compact solution for applications

that require voltage and current based protection of small and medium sized

generators.

The MVR-G215 is a compact generator protection relay for small and medium

sized generators. It comes with voltage and current based protection.

Communication interfaces and I/Os can be extended with the 3 available

extension slots as required by the individual application.

5x Current input (configurable 0.2…10A)

4x Voltage input (1.00…480.00V (RMS)

3x Digital input

5x Output relay (4NO, 1CO)

1x IRF output (1CO)

2x Remote com port (1 x RJ45 Ethernet and 1 x RS-485)

– IEC 61850 Ed1. Modbus TCP/RTU, IEC 60870-5-104/103/101. DNP 3.0. SPA protocols

– 3 extension slots for additional hardware options

– Event recorder (up to 15 000 events)

– Disturbance recorder (up to 100 disturbance records