Horner HE-RCC972 Compact Controller

RCC972   –   RCC Controller with eight (8) Digital inputs compatible with 12V/24VDC – four (4) DC Outputs

– .5A per point – Eight (8) 12-bit Analog Inputs 0-20mA and four (4) 12-bit Analog outputs 0-20mA

8 digital DC inputs, 4 digital outputs, 8 Analog Inputs and 4 analog outputs,

providing users with superior I/O options for a wide range of Process and Discrete Manufacturing applications

Provides superior connectivity – supporting both CAN and 10/100 Ethernet as standard

Inclusion of CAN provides the ability for the RCC to support hundreds of remote I/O points using Horner’s CsCAN

Digital & Analog Information

Digital Filtering module response to a temperature change.

The illustration above demonstrates the effect of digital filtering on (set with Filter Constant).

Analog Input – Raw input values for channels 1-4 are found in the registers as Integer-type data with a range from 0 – 32000.

Analog inputs may be filtered digitally with the Filter Constant found in the Cscape Hardware Configuration for Analog Inputs.

Valid filter values are 0 – 7 and act according to the following chart.

CAN Communications

The CAN port is provided via two connections: CAN_LOW (CL) and CAN_ HIGH (CH).

It may be used to communicated with the other OCS products using Horner’s CsCAN protocol.

Additionally, remote expansion I/O, such as SmartRail, SmartBlock, and SmartStix may be implemented using the CsCAN protocol.

If CsCAN expansion I/O is to be used, a 24VDC power source will be required on the CsCAN bus in order to power the expansion I/O modules.

Horner RCC SERIES Programming, Data Logging and Alerts

Programming, Data Logging and Alerts

Use the RCC’s built-in serial and Ethernet ports for Cscape programming. Utilise

Horner’s user-friendly, ladder-logic based PLC software, our IEC 6-1131 options, and

application defined communications.

Data logging, application updates and advanced recipe handling are made easy via the

built-in removable microSD™ memory card. Log process based on individual events

or specific times; everything is completely customisable – create virtual black box

functionality for your machine.

Versatility Meets Precision – Horner webOCS

Register RCC controllers with Horner webOCS products to monitor and control plant

data from the palm of your hand. Published directly from the OCS Controller, the

webOCS line allows the same or unique web pages to be monitored and controlled from

your computer, tablet or other mobile device. Developed completely within our Cscape

environment, webOCS allows for state-of-the-art HTML5 development without the need

for web programming skills.

Horner RCC SERIES Flexibility Meets Functionality

Flexibility Meets Functionality

The RCC series is smart enough to perfectly complement our OCS family and ideal for

applications where a screenless controller is the best fit. RCC controllers also pair well

with the remote capabilities of the Horner webOCS line of products.

The RCC controllers are equipped with a range of digital and analogue inputs and

outputs – providing users with superior I/O options for both Discrete and Process

Applications.

Additionally, most RCCs contain RS-232 & RS-485. CAN and 10/100 Ethernet – which

provides you with serial connectivity, I/O expansion, Ethernet communications and

advanced functions such as e-mail and web serving.

Programming, Data Logging and Alerts

Use the RCC’s built-in serial and Ethernet ports for Cscape programming. Utilise

Horner’s user-friendly, ladder-logic based PLC software, our IEC 6-1131 options, and

application defined communications.

Data logging, application updates and advanced recipe handling are made easy via the

built-in removable microSD™ memory card. Log process based on individual events

or specific times; everything is completely customisable – create virtual black box

functionality for your machine.

Horner RCC SERIES Simple Needs Agriculture

Provides original equipment manufacturers (OEMs), integrators, and automation

end-users with flexible, functional I/O and simple all-in one controller options without a built-in screen.

Agriculture

n   Increase overall productivity

n   Reduce energy consumption Building Automation

n   Improve occupant comfort

n   Economical operation systems Material Handling

n   Minimise HMI inefficiencies

n   Track/log/catalogue data Oil and Gas

n   Maximise capacity utilisation

n   Maintain emission standards Renewable Energy

n   Data logging, remote access

n   Sunlight and UV protection Water/Wastewater

n  Operate chlorination systems

n   Station pump control

Horner APG Thermocouple Input Module

DESCRIPTION

The Horner APG Thermocouple Input Modules allow thermocouple temperature sensors to be directly

connected to the PLC without external signal processing (transducers, transmitters, etc.).  All analog and

digital processing of the thermocouple signal is performed on the module.  These modules have a

resolution of 0.5°C, and temperature values may be reported to the PLC %AI I/O table in 0.5°C or 0.5°F

increments.  There are four standard resolution models available, with four input channels

(HE693THM409/HE693THM449), and with eight input channels (HE693THM809/HE693THM889).  All

models feature open circuit detection, where the temperature value written to the %AI register goes to its

maximum value upon an open circuit condition.  Two models (HE693THM449 and HE693THM889) also

feature %I alarm bits which energize on an open circuit condition.  The first four %I bits are used for the

HE693THM449 and the first eight %I bits are used for the HE693THM889.

Horner APG Thermocouple Input Module General


General

In order to meet CISPR (EN 55011) Group 1. Class A Radiated Emissions levels, all components in the

PLC system require the following:

• All components must be mounted in a metal enclosure or the equivalent.  The wiring must be

routed in metal conduit or the equivalent.  All surfaces of the enclosure must be adequately

grounded to adjacent surfaces to provide electrical conductivity.

• The metal conduit (flexible conduit is acceptable) for all wiring external to the cabinet must be

mounted to the enclosure using standard procedures and hardware to ensure electrical

conductivity between the enclosure and the conduit.

• An external EMI filter must be wired to the AC Main for the PLC.  Sprague Electric Part

Number 259A9098P3 (available from GE Fanuc), or any other EMI filter which provides

equivalent performance, may be used.

• An external ground wire (16 AWG (1.32 mm2), 6″ (15.24 cm) maximum length) must be wired

from the Series 90-30 power supply safety ground wire terminal to the metal enclosure.

• On AC Main Ports connected to PLCs, MOVs shall be connected Line to Line and Line to Ground.

• All cables and Analog signals must use shielded cable with a minimum of overall foil.