Characteristics in 3Mbit mode:
Works as input and output station at the same time
32+32 analog inputs and outputs plus 32+32 binary inputs and outputs per station
or
Up to 512+32 binary inputs plus 512+32 binary outputs
or
Eight complex terminals (i.e. SSI, incremental encoder etc.),
Fiber optic compatible with ibaPADU-8 and ibaPADU-8-O, that means up to 8
ibaNet750-BM-D I/O-devices on 1 bus (ring or star topology)
Integrated power supply for the modules (internal load up to 1.5 A)
For operation with ibaPDA there are restrictions regarding the time behaviour of the
terminals (no guaranteed simultaneous plant snapshot of all signals within 1ms cy
cles).
Operation without PC. Using this device mode, it is possible to replace conventional
copper wire bundles with ibaNet750-BM-D devices (up to 8x 136 digital signals in
each direction on 2 fiber optics).
The behavior of the device at the iba fiber optics bus is identical to one or four ibaPADU
8. ibaPADU-8AI-U/-I or ibaPADU-O devices. That means, that every device can send
and receive 8 (or 32) analog channels (16 bit each) and 8 (or 32) binary channels (8 bit),
in total 17+17 (68 + 68) Byte net data cyclically every millisecond. The devices can be
cascaded like ibaPADU-8 (ibaPADU-8-O) devices, with up to 8 devices per cascade. The
device converts the incoming data stream from the fiber optic link simultaneously and
exactly to the millisecond for all channels, regenerates the optical signal and sends it to
the other devices within the cascade. It is allowed to mix ibaPADU-8. ibaPADU-8-O and
ibaNet750-BM-D devices within an optical link.
An ibaFOB-D input card is required on the PC side. If ibaNet750-BM-D is used as re
placement for the predecessor ibaNet750-BM, even older PC cards (ibaFOB-io, ibaFOB
4i and ibaFOB-4i-S) can act as receivers.
Additionally each station can simultaneously be used as output device (like ibaPADU-8
O). This is in particular necessary when terminals with set/reset function are used, e.g.
counter etc. For this purpose, an ibaFOB-D card with output(s) is required on the PC
side.
To add more functions, ibaNet750-BM-D can also be used with the ibaLink-SM-64-io,
ibaLink-SM-128V-i-2o or ibaLink-VME card. This allows to create simple I/O extensions
for the systems Siemens Simatic S5 115U, 135U, 155U, as well as Siemens MMC216
and VME buses.