Welcome to the official website of CNIACS Automation Technology Co., Ltd!

KEBA KeConnect TM 2×0/A, TM225/A Product features

Product features

• Thermoelement type J, K, L

(TM 220/A, TM 240/A)

• For PT100 sensors

(TM 225/A)

• Internal and external cold junction compensation

• High measurement precision

• Sensor failure detection

• Electronic parameter chip

Short description

The TM 2xx/A series consists of temperature measurement modules that can be directly attached to CPU

modules and operated with all product lines of the KEBA control system by means of bus couplers.

TM 220/A, TM 240/A

Analog input modules TM 220/A and TM 240/A enable the direct connection of thermoelements (2-

conductor technique). The calibration and linearization of the temperature values takes place via a

microcontroller. A sensor failure, should it occur, is reported to the higher-level central module and can

be evaluated in the application.

Two operating modes are supported:

• Display of the actually measured temperature (standard mode)

• Display of the measured voltage in μV

Cold junction compensation can occur via internal temperature measurement at the terminals of the

module or optionally with the aid of external sensor TE 220/A (external terminal temperature

compensation).

KEBA KeConnect IM 270/W Compact modules

Digital inputs

Number of inputs 32

Input type Type 1 (acc. to EN 61131-2)

Voltage range for “1” 15 V ≤ U ≤ 30 V

Voltage range for “0”-3 V ≤ U ≤ 5 V

Status display Green LED

Min. update cycle 200 μs

Galvanic isolation No

Debouncing Configurable (via software)

Digital outputs 0.5 A

Number of outputs 16 (DO0 – DO15)

(2 groups of 8 outputs with their own supply)

Type Semiconductor output

Nominal voltage 24 V DC

Nominal current 0.5 A at 100 % simultaneity per group

Status display Orange LED (on the load side)

Galvanic isolation of the output groups No

Galvanic isolation of the control electronics No

Inductive load (energy) Max. 100 mJ at 0.2 Hz

Overload-proof Yes

Permanently short-circuit proof Yes

Short-circuit diagnosis Yes

Protected against polarity reversal No, defects possible

Digital outputs 2 A

Number of outputs 24 (DO16-DO39)

(3 groups of 8 outputs with their own supply)

Type Semiconductor output

Nominal voltage 24 V DC

Nominal current 2 A at 50 % simultaneity per group

Status display Orange LED (on the load side)

Galvanic isolation of the output groups Yes

Galvanic isolation of the control electronics Yes; electric strength 500 V AC

Inductive load (energy) Max. 1 J at 0.2 Hz

Overload-proof No

Permanently short-circuit proof Yes

Short-circuit diagnosis Yes

Protected against polarity reversal Yes

KEBA KeConnect IM 270/W Product features

Product features

• Cost- and space-optimized compact module,

especially well suited for plastic machines

• Supports the “fast control” concept

• Functions for changeover point recognition

• Connection via high-performance EtherCAT connection

• Direct expandability by means of KeConnect C2 modules

• Extensive diagnostic options

Short description

The IM 270/W is a cost- and space-saving compact module. It combines the typical I/O design for plastic

injection molding machines in one module and offers functions for changeover point detection. In

addition to application in the plastics sector, it can also be used in other areas.

The IM 270/W supports the “fast control” concept. Innovative EtherCAT communication between the

compact module and the CPU module is used here to minimize dead times and thereby greatly reduce

reaction times. This increases the performance of the machine considerably.

Depending on the type of inputs and outputs, various diagnostic possibilities are available, such as the

detection of sensor failures or short circuits.

The IM 270/W is connected to the CPU module via EtherCAT. To adapt the I/O configuration to the

application, KeConnect C2 modules can be attached at the side directly via the K-bus.

KEBA KeConnect AM 28x/x Analog hybrid modules

Analog inputs

AM 280/A AM 282/A AM 280/B

Number of inputs 4 4 4

Type Voltage input Voltage input Current input

Resolution 14 bit 16 bit 14 bit

Signal range ±10 V or 0 – Uref (10 V) ±10 V or 0 – Uref (10 V) 0 – 20 mA or 4 – 20 mA

Max. measurement signal ±10.4 V ±10.4 V-0.8 mA … 20.8 mA

Input type Differential or single-ended Differential or single-ended Differential

Galvanic isolation No No No

Reference voltage output 10 V ±2.5 %; max. 20 mA 10 V ±2.5 %; max. 20 mA

Scan repeat cycle 1 ms 1 ms 1 ms

Input impedance in signal range 10 MΩ 10 MΩ < 200 Ω

Input filter characteristic First order First order First order

Limiting frequency of the input filter 250 Hz 250 Hz 250 Hz

Conversion method Successive approximation Successive approximation Successive approximation

Monotonicity without error codes Yes Yes Yes

Common mode range ±13.5 V ±13.5 V ±13.5 V

Common mode rejection ratio > 80 dB > 80 dB > 80 dB

Value of the lowest bit (LSB) 1.3 mV 1.3 mV 1.35 μA

Maximum permitted continuous load

(without damage) ±30 V

Typ. temp. coefficient measurement error ±5 ppm of scale end value / °C

Max. temp. coefficient measurement error ±20 ppm of scale end value / °C

Largest error at 25 °C ±0.01 % of scale end value

KEBA KeConnect AM 28x/x Analog outputs

Analog outputs

AM 280/A AM 282/A AM 280/B

Number of outputs 4 4 4

Type Voltage output Voltage output Current output

Digital resolution 12 bit 14 bit 12 bit

Signal range ±10 V ±10 V 0 – 20 mA

Galvanic isolation No No No

Conversion cycle 1 ms 1 ms 1 ms

Value of the lowest bit (LSB) 5.32 mV 1.33 mV 5.39 μA

Monotonicity Yes Yes Yes

Load resistance ≥ 1000 Ω ≥ 1000 Ω ≤ 600 Ω

Largest capacitive load ≤ 10 nF ≤ 10 nF

Differential non-linearity ≤±1 LSB

Settling time when changing over the full

range (with ohmic load) ≤ 50 μs

Typ. temp. coefficient analog output error ±20 ppm of scale end value / °C

Max. temp. coefficient analog output error ±30 ppm of scale end value / °C

Largest error at 25 °C ±0.15 % of scale end value

KEBA KeConnect AM 28x/x Product features

Product features

•  4 analog inputs

•  4 analog outputs

•  Signal form: Voltage or current

•  Sensor failure detection

•  Resolution of the outputs up to 14 bit

•  Electronic parameter chip

Short description

The AM 28x/x series is a hybrid module and enables the connection of four analog inputs and four analog

outputs with voltage or current signals. The analog inputs of the AM 28x/A process both single-ended as

well as differential voltage signals. The AM 280/B is equipped with current inputs and outputs.

A sensor failure, should it occur, is reported to the higher-level CPU module and can be evaluated

accordingly in the application. These modules are attached directly to a CPU module or can be operated

with all KEBA controls by means of bus couplers.

Dimensions, weight

Height 120 mm

Width 22.5 mm front plate / 32.5 mm incl. plug

Depth 100 mm

Weight 135 g

KEBA KeProduct features

• 4 analog voltage outputs

• Resolution 12 bit

• Electronic parameter chip

Short description

KeConnect AO 240/A is an analog voltage output module. The outputs produce signals in the range of

±10 V with a resolution of 12 bit.

This module is attached directly to a CPU module or can be operated with all KEBA controls by means of a

bus coupler.

Environmental conditions

Operating temperature +5 °C … +55 °C

Storage temperature-40 °C … +70 °C

Relative air humidity 10 % to 95 % (non-condensing)

Vibration resistance / shock resistance Acc. to EN 61131-2

General

Supply voltage 24 V DC from K-bus, 5 V DC from K-bus

Overvoltage category II

Protection class III acc. to EN 61131-2

Addressing on K-bus Via 16-digit address switch, on the side

Type of terminals Open – pitch 5.08 mm

Power consumption K-bus 24 V 1.9 W

Power consumption K-bus 5 V 0.3 W

KEBA KeConnect AO 240/A Analog output modules

Analog outputs

Number / type of outputs 4 voltage outputs

Resolution 12 bit

Signal range ±10 V

Galvanic isolation No

Conversion cycle 1 ms

Value of the lowest bit (LSB) 5.32 mV

Monotonicity Yes

Load resistance ≥ 1000 Ω

Largest capacitive load ≤ 10 nF

Differential non-linearity ≤±1 LSB

Settling time when changing over the full range

(with ohmic load) ≤ 50 μs

Typ. temp. coefficient analog output error ±20 ppm of scale end value / °C

Max. temp. coefficient analog output error ±30 ppm of scale end value / °C

Largest error at 25 °C ±0.15 % of scale end value

Dimensions, weight

Height 120 mm

Width 22.5 mm front plate / 32.5 mm incl. K-bus plug

Depth 100 mm

Weight 135 g

Environmental conditions

Operating temperature +5 °C … +55 °C

Storage temperature-40 °C … +70 °C

Relative air humidity 10 % to 95 % (non-condensing)

Vibration resistance / shock resistance Acc. to EN 61131-2

KEBA KeConnect AI 240/A Analog input modules

Analog inputs

Number / type of inputs 4 voltage inputs

Resolution 14 bit

Signal range ±10 V or 0 – Uref (10 V)

Max. measurement signal ±10.4 V

Input type Differential or single-ended

Galvanic isolation No

Reference voltage output 10 V ±2.5 %; max. 20 mA

Scan repeat cycle 1 ms

Input impedance in signal range 10 MΩ

Input filter characteristic – order First order

Input filter limiting frequency 250 Hz

Conversion method Successive approximation

Monotonicity without error codes Yes

Synchroneity control ±13.5 V

Synchroneity suppression > 80 dB

Value of the lowest bit (LSB) 1.3 mV

Maximum permitted continuous load (wit

hout damage) ±30 V

Typ. temp. coefficient measurement error ±5 ppm of scale end value / °C

Max. temp. coefficient measurement error ±20 ppm of scale end value / °C

Largest error at 25 °C ±0.01 % of scale end value

Dimensions, weight

Height 120 mm

Width 22.5 mm front plate / 32.5 mm incl. K-bus plug

Depth 100 mm

Weight 135 g

Environmental conditions

Operating temperature +5 °C … +55 °C

Storage temperature-40 °C … +70 °C

Relative air humidity 10 % to 95 % (non-condensing)

Vibration resistance / shock resistance Acc. to EN 61131-2

KEBA KeConnect AI 240/A Product features

Product features

• 4 analog voltage inputs usable as differential inputs

or as single-ended inputs

• Resolution 14 bit

• Sensor failure detection

• Electronic parameter chip

Short description

Analog input module KeConnect AI 240/A features four analog voltage inputs that process differential or

ratiometric input signals in the range from ±10 V or 0-10 V with a resolution of 14 bit.

A sensor failure, should it occur, is reported to the higher-level central module and can be evaluated in

the application.

This module is attached directly to a CPU module or can be operated with all KEBA controls by means of a

bus coupler.

Environmental conditions

Operating temperature +5 °C … +55 °C

Storage temperature-40 °C … +70 °C

Relative air humidity 10 % to 95 % (non-condensing)

Vibration resistance / shock resistance Acc. to EN 61131-2

General

Supply voltage 24 V DC from K-bus, 5 V DC from K-bus

Overvoltage category II

Protection class III acc. to EN 61131-2

Addressing on K-bus Via 16-digit address switch, on the side

Type of terminals Open – pitch 5.08 mm

Power consumption K-bus 24 V 2 W

Power consumption K-bus 5 V 0.3 W

Search for products