ABB MNS iS Motor Control Center

MNS iS Design & Components

Switchboard Construction

MNS iS as part of the ABB Low Voltage Switchgear solution uses the well proven ABB MNS standard design aspects.

MNS aspects described in this section are fully applicable to MNS iS.

MNS system is a verified design in accordance with IEC61439-1/-2.

The consistent application of the modular principle both in electrical and mechanical design

as well as the use of standardized components allows its flexible and compact design.

Depending on operating and environmental conditions different design levels are offered.

Notable system advantages with regard to design aspects:

Compact, space-saving design

Easy project and detail engineering through standardised components

Verified design acc. IEC 61439-1/-2

Earthquake-, vibration- and shock-proof designs are available

Easy retrofitting without the need for switchgear de-energizing

Maintenance-free busbar construction

High operational reliability and availability

Optimum personal protection

ABB Instrumentation 2600T Pressure Transmitter family

INTRODUCTION

Instruction Manual Structure

The present manual provides information on installing, operating, troubleshooting the 364 pressure transmitter.

Every section of the present manual it is specifically dedicated to the specific phase of the transmitter

lifecycle starting from the receipt of the transmitter and its identification, passing to the installation,

to the electrical connections, to the configuration and to the troubleshooting and maintenance operations.​

General Safety Information

The “Safety” section provides an overview of the safety aspects to be observed for operation of the device.

The device has been constructed in accordance with the state of the art and is operationally safe.

It has been tested and left the factory in perfect working conditions.

The information in the manual, as well as the applicable documentation and certificates,

must be observed and followed in order to maintain this condition throughout the period of operation.

Full compliance with the general safety requirements must be observed during operation of the device.

In addition to the general information, the individual sections in the manual contain descriptions of processes or procedural instructions with specific safety information.

Only by observing all of the safety information you can reduce to the minimum the risk of hazards for personnel and/or environment.

These instructions are intended as an overview and do not contain detailed information on all available models or 

every conceivable event that may occur during setup, operation, and maintenance work.

For additional information, or in the event of specific problems not covered in detail by these operating instructions,

please contact the manufacturer. In addition, ABB declares that the contents of this manual are not part of any

prior or existing agreements, commitments, or legal relationships; nor are they intended to amend these.

All obligations of ABB arise from the conditions of the relevant sales agreement,

which also contains the solely binding warranty regulations in full.

These contractual warranty provisions are neither extended nor limited by the information provided in this manual

ABB 266DSH Differential pressure transmitters


Wet and dust-laden atmospheres

The transmitter is dust and sand tight and protected

against immersion effects as defined by IEC 60529 (2001)

to IP 67 (IP 68 on request) or by NEMA Type 4X.

IP65 with Harting Han connector.

Aluminium and AISI housings as barrel version also comply

to IP 66 as defined by IEC 60529 (2001).

IP66W/IP67W/IP68W as standard for Inmetro certification.

Specification – performance

Stated at reference condition to IEC 60770 ambient

temperature of 20 °C (68 °F), relative humidity of 65 %,

atmospheric pressure of 1013 hPa (1013 mbar), mounting

position with vertical diaphragm and zero based range for

transmitter with isolating diaphragms in AISI 316 L ss or

Hastelloy and silicone oil fill and HART digital trim values

equal to 4 mA and to 20 mA span end points, in linear mode.

Unless otherwise specified, errors are quoted as % of span.

Some performance referring to the Upper Range Limit are

affected by the actual turndown (TD) as ratio between

Upper Range Limit (URL) and calibrated span.

Emerson Ethernet I/O Card (EIOC) Supported Industrial Ethernet Protocols

Supported Industrial

Ethernet Protocols:

Modbus TCP Interface

The Modbus TCP interface will support Modbus data

sources such as PLCs, MCCs, analyzers and similar devices

communicating Modbus TCP. The Modbus TCP interface is a

Modbus Client reading and writing data from/to Modbus Server

devices. The Modbus server devices can be Modbus TCP devices

or Modbus serial devices using a Modbus TCP gateway.

The Modbus TCP interface supports the following types of

data access:

„ Reading input data from Modbus Coils, Discrete Input,

Holding Registers, and Input Registers.

„ Writing output data to Coils and Holding registers.

All reads will be performed periodically and outputs will be

sent when they are written.

EtherNet /IP

The EtherNet/IP protocol allows data sources such as

PLCs, Intelligent Field Devices (IFDs), variable-speed drives,

MCCs, and analyzers; as well as other devices communicating

EtherNet/IP to connect directly in to DeltaV via the EIOC.

The EtherNet/IP interface will support connections for

both implicit and explicit messaging to allow access to both

Class 1 and Class 3 EtherNet/IP I/O adapters. Redundancy with

EtherNet/IP Class 1 Implicit and Class 3 Explicit messaging

for control (sending outputs to the devices) require special

considerations due to exclusive owner communications defined

by the protocol. Please refer to the DeltaV System Planning

Guide for more information. Class 3 PCCC and UCMM with

Logix tags message classes are also supported.

Emerson Ethernet I/O Card (EIOC) Product Description

Product Description

The EIOC is a big pipe for the integration of process data from

3rd party Ethernet Devices, such as PLCs and smart field devices

such as Intelligent Field Devices (IFDs) and Intelligent Electronic

Devices (IEDs). A network of these Ethernet Devices can be

directly connected to the EIOC. The Ethernet Devices can

communicate to the EIOC using one of five protocols;

Modbus TCP, EtherNet/IP, IEC61850 MMS, OPC UA client

and EtherNet/IP Control Tag Integration. The EIOC connects

directly into the DeltaV Control Network and can be placed

remotely in an enclosure in the field.

The EIOC is an independent embedded data server. This means

that there is no need for a separate controller to process the

data being integrated into the EIOC. Control Modules needed

to process the data from the Ethernet Devices are assigned and

executed in the EIOC. In this way, communications with the

devices are fast and direct. Any parameters from the modules

running in the EIOC can be read by both S-series and M-series

controllers using External References when needed in control

strategies at the controller level.

Emerson Ethernet I/O Card (EIOC) Introduction

„ Powerful solution that communicates directly

to external Ethernet Device Networks

„ Easy connection to devices using Modbus TCP,

EtherNet/IP, IEC61850 MMS, OPC UA client or

EtherNet/IP Control Tag Integration protocols

„ Proven S-series packaging

„ Modular with easy to add redundancy

„ Communication to any M- and S-series Controller

Introduction

The Ethernet I/O Card (EIOC) provides a platform to access data

from Ethernet devices in the DeltaV™ system. Ethernet Devices

capable of talking Modbus TCP, EtherNet/IP, IEC 61850 MMS

(Manufacturing Message Specification), OPC UA client and

EtherNet/IP Control Tag Integration protocols are supported.

The EIOC provides monitoring and control of Ethernet Devices

on the Ethernet Device Network via control modules assigned

to and executed in the EIOC. Ethernet Devices like PLCs,

Motor Control Centers, drives, switchgear and others can be

controlled directly by the EIOC, independent of a controller

Emerson DeltaV™ Wireless I/O Card Product Description

Product Description

The WIOC is a native DeltaV I/O node that supports up to 100

wireless devices. The cards install on a 2-wide carrier, with each

card having its own Smart Wireless Field link. The WIOC can be

commissioned in a simplex mode if no redundancy is needed.

The WIOC allows redundancy to be completed later, when

needed – online and bumpless.

The WIOC carrier has two Ethernet IO Ports that connect to the

DeltaV Area Control Network and are available with copper or

fiberoptic media. The Smart Wireless Field links are connected

to the I/O card using a 4-conductor cable. The cable has a pair of

wires for power and a pair for the communication to the

field link.

The WIOC uses the Smart Wireless technology supported by

WirelessHART devices and a Self-Organizing Network.

„„ No wireless expertise is required; devices automatically find

the best communication paths with Adaptive Mesh Routing.

„„ Network continuously monitors paths for

degradation and repairs itself.

„„ Adaptive behavior provides reliable, hands-off

operation and simplifies network deployments,

expansion, and reconfiguration.

Emerson DeltaV™ Wireless I/O Card Introduction

• Fully redundant wireless solution from Wireless

I/O Card (WIOC) to the Smart Wireless Field Link

• Optional simplex for smaller applications

• Seamless integration with DeltaV™ system and

AMS Device Manager

• Industry proven security

• WirelessHART® delivers PlantWeb®

Introduction

A robust wireless solution is much more than the sum of its

parts; it is the result of innovative integration with consideration

given to every aspect of the overall system. A Smart Wireless

solution consists of the measurement devices, the selforganizing

network, and easy integration with the DeltaV system.

Emerson Automation Solutions offers a full portfolio

of wireless solutions enabled by self-organizing WirelessHART

networks. The DeltaV system and AMS Device Manager provide

seamless integration with the Wireless I/O Card. WirelessHART

devices are the easiest devices to add to your existing control

system! All the benefits of HART including HART device alerts

for wireless devices are native with the latest DeltaV system and

AMS Device Manager releases.

Emerson DeltaV™ SX Controller Product Description

Product Description

The SX controller primary function is to execute control

modules that are designed to meet the specific control

requirements of the plant. These control modules use process

signals from the controller’s I/O subsystem and provide

communication of process data to the rest of the DeltaV

control system for operator interaction and data collection.

Each controller node can be installed as a simplex or redundant

node. The controllers are connected to the I/O carriers,

which are mounted to the right of the controller carriers.

Up to 8 carriers with 8 cards each can be connected to the

local bus I/O, for a total of 64 traditional I/O cards. In addition

to the 8 local I/O carriers, each controller can communicate

with an additional 16 Remote I/O units hosting traditional

card based I/O.

Emerson DeltaV™ SX Controller Introduction

„ Scalable controllers

„ Quick assembly

„ Easy-to-use

„ Field proven architecture

„ Designed for Electronic Marshalling

„ Advanced controls

Introduction

The DeltaV™ SX controller provide communication and

control functions and integrate field devices and the other

nodes on the control network. The SX and SQ controllers

provide a choice to match the controller capacity to the

requirements of the process. They also provide new ease

of use features that eliminate mounting screws and accelerate

cabinet assembly.

Control strategies and system configurations created on

earlier DeltaV systems can be used with this powerful

controller. The SX Controller provides all the features

and functions of the M-series controllers including support

for CHARM based Electronic Marshalling.

The control languages executed in the controllers are

described in the Control Software product data sheet.