Welcome to the official website of CNIACS Automation Technology Co., Ltd!

Alfa Laval LKH Prime Standard design

Standard design

All media contacting steel components like pump casing,

impeller, airscrew, front cover, recirculation pipe and backplate are

in W. 1.4404 (AISI 316L). A stainless steel shroud protects the

motor and four adjustable stainless steel legs support the

complete unit.

A compression coupling securely attaches the stub shaft to the

motor shaft with precision alignment, and the semi-open impeller

with a special vane design ensures efficient handling of the

product as it moves through the pump.

As standard, the LKH prime pump is equipped with a single

mechanical shaft seal but is also available with a double

mechanical shaft seal. The front-loading shaft seal, with the

spring and washers mounted on the atmospheric side, makes

maintenance fast, easy and inexpensive. It takes just a few

minutes to replace the shaft seal. In addition, the balanced design

minimizes the risk of seal opening during unforeseen pressure

shock.

Alfa Laval LKH Prime Working principle

Benefits

• Energy efficient: superior efficiency resulting in reduced energy

consumption and CO2 footprint.

• Hygienic: designed according to the most stringent hygienic

design standards and with verified and effective CIP

cleanability.

• Quiet: operates very quietly compared to other self-priming

pumps improving the working environment.

• Reduced capital investment: designed for Cleaning-in-Place

(CIP) duties containing entrained air but can also pump

product reducing need for additional pump.

Working principle

On applications where the pumped media contains a mixture of

air and liquid in the suction line, airscrew rotation causes the

formation of a continuous liquid ring within the canister. Due to the

eccentric position of the canister relative to the airscrew, an air

chamber forms between the liquid ring and the airscrew, which

separates into air pockets between the air-screw vanes.

The continuous rotation of the air-screw forces air pockets

through the canister into the suction stage of the impeller which

are then pumped out via the discharge.

Liquid is returned from the discharge via the recirculation pipe into

the canister to ensure the liquid ring is maintained at all times.

Alfa Laval LKH Prime Centrifugal pumps

Introduction

Based on the market-leading Alfa Laval LKH pump, the Alfa Laval

LKH Prime Centrifugal Pump is a versatile, highly efficient self

priming pump for use in hygienic applications, especially tank

emptying and CIP return applications. With its combination of air

screw technology and advanced design, the pump can remove air

from the suction pipe.

Precision-engineered, the LKH Prime delivers greater energy

efficiency than similar pumps. Its optimized design, premium

motor, tight tolerances and advanced impeller and airscrew

design minimize recirculation and reduce energy consumption.

Application

The LKH Prime pump is designed to meet the stringent hygienic

requirements across the food, dairy, beverage, and home

personal care industries. It is ideal for tank emptying and CIP

return applications. With verified and effective CIP cleanability,

the LKH Prime can be used as a product pump as well.

The LKH Prime is available in three sizes to handle capacities up

to 100 m3/h and differential pressures up to 7.5 bar at 50 Hz.

Basler Electric BE3-25 Synchronizing Check Relays

INTRODUCTION

BE3-25 sync-check relays are used to ensure that two ac

circuits are synchronized. In order to be synchronized, the

frequency, phase angle, and voltage of the two circuits must

be within preset limits. When this occurs, the BE3-25 output

relay energizes. The primary application of the BE3-25 is to

enable additional generators to be brought on-line without

machine damage or system disturbance. The BE3-25 can

also be used to supervise reclosing or in any instance where

the danger of paralleling two circuits out of synchronism

exists.

Basler Electric BE3-25 APPLICATION

APPLICATION:

The BE3-25 series are synchronizing check relays, also known

as paralleling relays. They are used to ensure that two AC

supplies are synchronized. For a system to be synchronized,

the frequency, phase angle, and voltage must be within preset

limits. The BE3-25-****4 can monitor either utility mains bus

bar and incoming generator, or two generators. 

The BE3-25-****4 offers user adjustment of the reset voltage

from 10 to 30%. This voltage corresponds to 6 to 20 electrical

degrees. The unit compares the input voltage and phase

relationship of the bus bar to that of the generator.

When the signal is within the preset limits, the relay energizes.

The BE3-25-****5 operates as the BE3 25-****4.

but has the additional feature of a dead bus facility.

This enables the relay to energize with a generator supply

only, which is a common requirement when utility mains failure

occurs.

Basler Electric BE3 Series Benefits

Benefits

• Simplify protection by covering a wide range of applications using

BE3 relays.

• Accurate, repeatable, and reliable operation.

• Most models are available for shipment from stock.

• Easy, time-saving installation with BE3 DIN-rail devices.

• Provide economical industrial protection for motor, generator,

transformer, distribution, process control, and automatic transfer

applications.

• Many BE3 relay models are self-powered, eliminating the need for

additional power sources.

Basler Electric BE3 Series Industrial Relays

BE3 Series Industrial Relays provide a wide range of cost-saving options to simplify industrial

application protection related to Auto Transfer, Distribution, Generators, Motors, Process

Control, and Transformers. Multiple DIN-rail mounting options are available.

Features

• 25 Sync-Check

• 27 Undervoltage

• 27T Undervoltage with Time Delay

• 27/59 Undervoltage/Overvoltage

• 27T/59T Undervoltage/Overvoltage with Time Delay

• 32 Reverse Power

• 37 Undercurrent

• 37/51 Undercurrent/Overcurrent

• 47 Phase Sequence

• 47N Phase Balance

• 47N/27 Phase Balance with Undervoltage

• 49R (3 or 6 RTDs) Temperature Relay

• 49TH Thermocouple Overtemperature

• 49TL Thermocouple Undertemperature

• 51 Overcurrent

• 59 Overvoltage

• 59T Overvoltage with Time Delay

• 74SL, SH, SD Millivolt Undervoltage, Overvoltage, Under/Overvoltage

• 74TL, TH, TD Milliamp Undercurrent, Overcurrent, Under/Overcurrent

• 74VL, VH, VD DC Undervoltage, Overvoltage, Under/Overvoltage

• 76SH DC Overcurrent with Inverse Time Delay

• 81O Overfrequency

• 81U Underfrequency

• 81O/U Overfrequency/Underfrequency

• 81OT Overfrequency with Time Delay

• 81UT Underfrequency with Time Delay

• 81OT/UT Overfrequency/Underfrequency with Time Delay

Basler Electric BE1-59N Benefits

Benefits

• Limit generator damage with 100% stator ground-fault protection.

• Wide range of applications covered with four overvoltage and four

undervoltage setting ranges.

• Meet protection timing requirements with instantaneous-, definite-, and

inverse-time characteristics options.

• Accurate detection of fundamental and third harmonic content using 40

dB harmonic filtering.

• Minimized potential transformer (PT) costs as a result of low sensing

burden.

• Reduced battery load with low burden power supply.

• Accurate, repeatable, and reliable operation.

• Simple human-machine interface (HMI) provides clear and intuitive

settings for easy configuration.

• LED targets provide clear annunciation of status.

• Easily perform in-case system and device tests using test plugs.

Basler Electric BE1-59N Ground Fault Overvoltage Relay

Overview

The BE1-59N provides accurate 100% stator-ground protection for ungrounded

and high-resistance grounded generators.

Features

• Provides 100% stator ground fault protection.

• 100/120 Vac or 200/240 Vac nominal sensing input.

• Four sensitivity ranges for overvoltage: 1 to 20 and 10 to 50 Vac for a

100/120 Vac input and 2 to 40 and 20 to 100 Vac for a 200/240 Vac

input.

• Four sensitivity ranges for undervoltage: 0.1 to 2.5 Vac and 0.5 to 12

Vac for a 100/120 Vac input and 0.2 to 5 Vac and 1 to 24 Vac for a

200/240 Vac input.

• Instantaneous, definite, and inverse time characteristics.

• 40 dB harmonic filtering.

• Low sensing input burden.

• Power supply status contact.

Alfa Laval T6 Benefits & Features

Benefits

• High energy efficiency – low operating cost

• Flexible configuration – heat transfer area can be modified

• Easy to install – compact design

• High serviceability – easy to open for inspection and cleaning

and easy to clean by CIP

• Access to Alfa Laval’s global service network

Features

Every detail is carefully designed to ensure optimal performance,

maximum uptime and easy maintenance. Selection of available

features, depending on configuration some features may not be

applicable:

• CurveFlowTM distribution area

• ClipGripTM gasket attachment

• Offset gasket groove

• OmegaPortTM noncircular port holes

• Leak chamber

• SteerLockTM plate alignment

• FlexFlowTM plate design

• Compact frame

• Fixed bolt head

• Key hole bolt opening

• Lifting lug

• Lining

• Lock washer

• Tightening bolt cover

Search for products