The FloBoss S600 Flow Manager is designed for

use either as a stand alone Flow Computer or as a

system component. The base unit is supplied with

a single Input/Output (I/O) board and can be used

for both gas and liquid applications. The I/O

capability of the single I/O board is detailed on

Page 5. but is generally suitable for 2 of 3 streams

and a header. Additional I/O boards can be added

(maximum of 3) to enable a single FloBoss S600

to handle up to 10 streams and up to 2 headers,

with both Gas & Liquid in a single machine. Orifice,

ultrasonic, turbine, positive displacement, Coriolis,

Annubar, Venturi, and V-Cone flow meter types

are all supported.

The Floboss S600 uses distributed processing to

achieve maximum performance. The main CPU

incorporates a hardware floating point processor.

Each additional card also has local processing to

convert inputs and output from engineering units to

field values and vice-versa, as well as running

background tests and PID loops.