The flow computer also supports two user periodic
logs, the duration or period of each is user selectable
between 1 second and 200 hours. The first user
periodic logs include 10 parameters over 4.000 periods
and the second contains 20 parameters over 500 periods.
The flow computer with FBxConnect provides pre
formatted EFM reports for hours and days. The format
of the reports can be .csv, .pdf, or secure .pdf.
In addition to the above reports, the flow computers
can produce FLOWCAL-compliant .cfx files through the
FBxConnect tool as well as calibration reports which
contain U.S. Bureau of Land Management specific parameters.
▪ Hourly logs
▪ Daily logs
▪ Weekly logs
▪ Monthly logs
62 days or 1500 records
12 months or 365 records
12 months or 52 records
60 months or 60 records
Note: This is only the initial default history. With the
flexible history design, the number of variables
and the time duration for different periodic
logs can be adjusted to meet the application requirement.