The flow computer also supports two user periodic

logs, the duration or period of each is user selectable

between 1 second and 200 hours. The first user

periodic logs include 10 parameters over 4.000 periods

and the second contains 20 parameters over 500 periods.

The flow computer with FBxConnect provides pre

formatted EFM reports for hours and days. The format

of the reports can be .csv, .pdf, or secure .pdf.

In addition to the above reports, the flow computers

can produce FLOWCAL-compliant .cfx files through the

FBxConnect tool as well as calibration reports which

contain U.S. Bureau of Land Management specific parameters.

▪ Hourly logs

▪ Daily logs

▪ Weekly logs

▪ Monthly logs

62 days or 1500 records

12 months or 365 records

12 months or 52 records

60 months or 60 records

Note: This is only the initial default history. With the

flexible history design, the number of variables

and the time duration for different periodic

logs can be adjusted to meet the application requirement.