Applications
Mining and metals Furnaces, kilns, boilers
Chemicals, extruders Autoclaves
Pharmaceutical sterilisers, dryers
Railway/ Infrastructure Burner Mgmt,
HVAC/ data centres Combustion control
Pulp & Paper Emergency Shutdown
Cement and glass Pipeline monitoring
Power Leak Prevention
Functional Overview
– Supports split-rack redundancy
– Supports Honeywell FDM (Field Device Manager) with HART IP
– Supports HART function blocks (Commands 3 and 48)
Note: HART support requires a UIO module
– Non-redundant and redundant architectures
– Sequence of Events Support (SOE)
Note: Supported only in non-redundant UIO configurations.
– Redundant and Non-Redundant Safe General Purpose IOs
– PID control with advanced Accutune III auto-tuning
– Secure peer-to-peer communication between ControlEdge HC900 controllers
– External watchdog timer with independent clock to detect unexpected CPU lockups
– Adjustable recipe pool memory allocates memory for recipes, SP profiles, sequences, and schedules to meet your needs
– Up to 4608 points can be connected via remote I/O
– Boolean logic programming. powerful combination of over 100 algorithms
– Advanced floating-point maths functions.
– Extensive alarm and event monitoring
– Up to 2304 galvanically isolated analogue input points
– Up to 1008 redundant UIO points
– New I/O voting and output verification function blocks.
– Remote I/O racks with wires for extended distances.
– Star or ring topology on the IO network using recommended switches
– Scanners and I/O plugged in and out while powered
– LED on/off indicators on digital I/Os
– Graphical Function Block Configuration
– Open 10MB or 10/100MB Ethernet interface using Modbus/TCP. Point-to-point communication via Ethernet
– Priority email alarm/event messages
– Ramp/soak setpoint programmer
– Setpoint scheduler with multiple outputs
– Sequencer with 16 outputs each
– Modbus read/write parameters can be assigned to fixed or custom addresses for HMI or monitoring software access.
– Modbus TCP Initiator
– Gas flow function block compliant with American Gas www.cniacs.com Association specifications. (Non-safety configurations only).
– Calendar module for triggering events
– Non-intrusive process/safety worksheets to handle both process and safety configurations.
– Built-in version control
– Quick update – 10 ms digital update and UIO (900U02-xxxx) 100 ms analogue update
Note: Low level AI update time is 0.5 seconds.