General Technical Data
Ambient Temperature: 0…+25° C for site altitude up to 1000 m amsl (at rated values).
It is vital to consult our applications department for ambient temperatures
above 40° C and/or any enclosed environment.
Power De-rating:
(currents and torques)
1% / °C in range 40° C…50° C up to 1000 m amsl for site altitude above 1000 m amsl and 40° C
» 6% up to 2000 m amsl
» 17% up to 3000 m amsl
» 30% up to 4000 m amsl
» 55% up to 5000 m amsl
For site altitudes above 1000 m amsl, no de-rating with temperature reduction of 10° C / 1000 m
Temperature De-rating: If the application requires de-rating due to lower motor surface temperature,
please contact our applications department.
Ball-bearing Life: ≥ 20.000 operating hours
Phasing Diagram – All Motors
• When the motor is rotated C.W. (viewed from drive shaft end), the
following Bemf voltage waveforms result:
• Voltage phase-U, leads Voltage phase-V, by 120-degrees
• Voltage phase-V, leads Voltage phase-W, by 120-degrees
• Voltage phase-W, leads Voltage phase-U, by 120-degrees