AMPLIFIER SPECIFICATIONS Amplifier Specifications:
Electrical Characteristics
– Closed-loop speed bandwidth up to 400 Hz
– Motor current ripple frequency 16 kHz
– Switching frequency: 8 kHz
– Long-term speed regulation (0.01%)
– Position loop update rate 250 µs (4 kHz)
– Speed loop update rate 250 µs (4 kHz)
– Commutation update rate 62.5 µs (16 kHz)
– SVM Current loop update rate 62.5 µs (16 kHz)
Fault protection
– Output phase-to-phase and phase-to-ground short circuit protection
– Overvoltage protection
– Undervoltage protection
– Over-temperature (motor and amplifier)
– Overspeed
– Overcurrent
– Feedback loss
– Foldback
– Loss of power supply
– Excessive position error
Environmental
– Operating range
– Ambient temperature 0 to 45°C www.cniacs.com (derated to 55°C above ambient)
– Storage temperature -25°C to 55°C
– Humidity (non-condensing) 85% maximum
Speed loop compensation
– PI Plus controller (PDFF format) or PI controller
– Field adjustable and digitally repeatable
Position loop compensation
– Proportional loop with feed forward
Analogue Inputs/Outputs
– 2 configurable inputs: ±10V, 12 and 14 bit resolution
– 2 configurable outputs: ±10V, 10-bit resolution
Digital Inputs/Outputs
– 4 Configurable Inputs: 24 Volt, PLC Compatible
– 2 Configurable Outputs: 24V (open collector), PLC compatible
– Remote Enable Input: 24 Volt, PLC Compatible
Drive Status Relay (BTB/RTO)
– Contact Closure, 0.5 Amp Rating, 24 Volt
Pulse or Master/Slave Inputs
– Pulse command: pulse/direction or quadrature encoder format
– RS-485 Receiver
– Up to 16 slave amplifiers can be connected
– Input ratios configurable
User position feedback (encoder-equivalent output port)
– Configurable as encoder equivalent (ROD) or SSI format
– Encoder Equivalent (ROD): A quad B with marker (zero) pulses, RS-485 Driver
– SSI (Serial Synchronisation Interface): 1.5 Mhz maximum clock frequency, RS-485 driver
– Programmable Resolution