All VibroSmart modules and devices
communicate using a system bus (SBUS), based
on Ethernet technology, that supports data
transfer rates of 100 Mbps at distances up to
100 m. The SBUS ensures the transfer of both nonreal-
time (standard) and real-time (time critical)
information between VibroSmart modules, and
supports communication with the host computer
running the VibroSight software.
VibroSmart modules can either be located sideby-
side (adjacent to each other) or separate
from one another. This flexibility allows the
functionality of the monitoring system to be
distributed depending on the size of and access
to the machinery being monitored. It also helps
reduce the expensive sensor cabling typically
required between sensors and monitoring
modules, by effectively replacing it with lower
cost Ethernet and power supply cabling.