Self Diagnostics

CPU failure, hardware failure, configuration error,

and over-range error for differential pressure, static

pressure and capsule temperature.

User-configurable process high/low alarm for

differential pressure and static pressure is also

available.

Signal Characterizer (Output signal code D, J and Q)

User-configurable 10-segment signal characterizer

for 4 to 20 mA output.

SIL Certification

EJA-E series transmitters except Fieldbus,

PROFIBUS PA and 1-5V DC with HART (Low Power)

communication types are certified in compliance with

the following standards;

IEC 61508: 2010;

Functional Safety of Electrical/electronic/

programmable electronic related systems; SIL 2

capability for single transmitter use, SIL 3 capability

for dual transmitter use.

Reliability Data different depending on hardware and

software revision.

For details, refer to Functional Safety Data Sheet.

(Document number: TI 01C25A05-01EN or TI

01C25A05-21EN for option code SLT )

The document can be downloaded from the website

of Yokogawa.