SPECIFICATIONS

Power supply 

   [Standard] ……………………………………………… 12/24 VDC (9.5 to 32 VDC) 

   [N, XN and NYB Packages] ………………. 90 to 250Vac / 120 to 375 Vdc; 

    …………………………………… 100 to 240 Vac -15%/+10% (UL rating only) 

Intrinsic consumption …………………………………………………….  max. 10 W 

Ambient temperature (operation)……………………………………. -20 to 70 °C 

                                                     [N, XN and NYB Packages] -20 to 60 °C  

Ambient temperature (storage) ……………………………………… -30 to 80 °C 

Ambient humidity ……………………………………………. 95%, non-condensing 

Voltage……………………………………………………………………………… ( /) 

 [1] 100 Vac  Rated (Vrated) ………………………………….. 66/115 VAC 

 Max. value (Vmax) ………………………………………. 150 VAC 

 or [4] 400 Vac  Rated (Vrated) ………………………………… 230/400 VAC 

 Max. value (Vmax) ………………………………………. 300 VAC 

  Rated surge volt. (Vsurge) ………………………. [1] 2.5kV, [4] 4.0 kV 

Accuracy …………………………………………………………………………. Class 1 

Measuring frequency …………………………………….. 50/60 Hz (40 to 70 Hz) 

Linear measuring range ……………………………………………….. 1.3 x Vrated 

Input resistance ……………………………… [1]0.21 MOhms, [4]0.696 MOhms 

Current     Rated (Irated) ………………………………………. [1]…/1A, [5] … /5A 

Linear measuring range …………………………………………………….. 3.0×Irated 

Burden …………………………………………………………………………. < 0.15 VA 

Rated short-time overcurrent (1 s) …………………….[1] 50×Irated, [5] 10×Irated 

Discrete inputs ………………………………………………………………..isolated 

Input range………………………………………… 12/24 VDC or 18 to 250 Vac/dc 

Input resistance ………………………………. approx. 6.8 kOhms or 68 kOhms 

Relay outputs ……………………………………………………………………. isolated 

Contact material …………………………………………………………………… AgCdO 

Load (GP) (Vcont, relay output) AC: …………………………………. 2.00 AAC@250 VAC 

 DC: 2.00 ADC@24 VDC / 0.36 ADC@125 VDC / 0.18 ADC@250 VDC 

Pilot Duty (PD) AC: ………………………………………………………………….. B300 

 DC: 1.00 ADC@24 VDC / 0.22 ADC@125 VDC / 0.10 ADC@250 VDC 

Analog Outputs (isolated) ………………………………………….. freely scalable 

Type ……………………………………………………………± 10 V / ± 20 mA / PWM 

Insulation voltage (continuously, AVR out)………………………………… 300 VAC 

Insulation voltage (continuously, Gov out) ………………………………… 100 VAC 

Resolution …………………………………………………………………………….. 12 Bit 

± 10 V (scalable) ……………………………………..internal resistance 500 Ohms 

± 20 mA (scalable) ………………………………………. maximum load 500 Ohms 

Housing Front panel flush mounting ………… Type APRANORM DIN 43 700 

Dimensions  WxHxD …………………………………. 144 × 72 × 122 mm 

Front cutout  WxH …………………………….. 138 [+1.0] × 68 [+0.7] mm 

Connection (screw/plug terminals depending on connector) .. 1.5 mm² or 2.5 mm² 

Front ……………………………………………………………………. insulating surface 

Protection System / Sealing ………………………………………………………………  

  Front ………………………… IP42 with correct installation 

  Front …………………. IP54 (with gasket P/N 8923-1037) 

  Back …………………………………………………………. IP20 

Weight ………………………………………………………………………. approx. 800 g 

Listings tested according to applicable IEC standards …………………………..  

 ……………………………………………… CE, UL/cUL listing for ordinary locations 

Marine (Pending) …………………. LR (Type Approval), ABS (Type Approval)