The ED3362-0100 analog input terminal enables the direct connection

of two independent resistance bridges (strain gauges – SG) or load

cells using 4-wire or 6-wire connection technology. It records the ratio

of the bridge voltage UBridge to the measured supply voltage USense

and outputs the calculated load value as a process value based on the

terminal settings. This enables precise recording of weights, torques,

and vibrations.

Special features:

• integrated, switchable 5 V/10 V bridge supply UExc, generated from

the power contacts

• parallel connection of bridges possible due to powerful bridge supply

• sampling rate of 10 ksps

The ED series EtherCAT Terminals have push-in connection technology

which makes wiring easy and tool-free.