Beckhoff EL3681-0030 | EtherCAT Terminal, 1-channel analog input, multimeter

The EL3681-0030 EtherCAT Terminal enables measurement of currents

and voltages in a wide input range. The measuring ranges are switched

automatically, as usual in advanced digital multimeters.

For current measurements, two current paths are available, one of which

is a high-current path for up to 10 A. The current and the voltage

measurement facility can be used for DC and AC.

The alternating parameters are output as true RMS values. 

The measurement readings can be read and processed with EtherCAT.

At the same time, the EL3681-0030 enables the measuring type and range

to be set via the bus.Excellent interference immunity is achieved through

the fully electrically isolated design of the electronic measuring system and

the dual-slope conversion system. High precision and simple, high-impedance

measurement from 300 mV to 300 V allow the EtherCAT Terminal to be used

like a modern digital multimeter.

In measuring applications in particular, the voltage to be expected is often

not yet known during the planning phase. Automatic adjustment of the

measurement range simplifies use and reduces stock levels.

The selected measuring type and overload are indicated by LEDs.

For the EL3681-0030. an individual calibration certificate is available, currently

as a choice of DAkkS or IS0 17025-compliant certificate. The certificate is issued

by an accredited service provider in collaboration with Beckhoff.

The individual calibration certificate for each device, in accordance with ISO

17025 or DAkkS, depending on the device variant, can be downloaded here.

These calibration certificates are issued for Beckhoff by an accredited service

provider. Recalibration on request.

Beckhoff EL3681 | EtherCAT Terminal, 1-channel analog input, multimeter, 300 V AC/DC, 10 A, 19 bit

The EL3681 EtherCAT Terminal enables measurement of currents and

voltages in a wide input range. The measuring ranges are switched

automatically, as usual in advanced digital multimeters. For current

measurements, two current paths are available, one of which is a high

-current path for up to 10 A. The current and the voltage measurement

facility can be used for DC and AC. The alternating parameters are

output as true RMS values. The measurement readings can be read

and processed with EtherCAT. At the same time, the EL3681 enables

the measuring type and range to be set via the bus.

Excellent interference immunity is achieved through the fully electrically

isolated design of the electronic measuring system and the dual-slope

conversion system. High precision and simple, high-impedance

measurement from 300 mV to 300 V allow the EtherCAT Terminal to be

used like a modern digital multimeter.

In measuring applications in particular, the voltage to be expected is often

not yet known during the planning phase. Automatic adjustment of the

measurement range simplifies use and reduces stock levels. The selected

measuring type and overload are indicated by LEDs.

This terminal is also available as a variant with an individual calibration

certificate. (See related products)

Beckhoff EL3475-0200 | EtherCAT Terminal, 12-channel analog input, 4-port

The EL3475-0200 is a 12-channel analog input that, with a 24-bit

resolution and an input voltage of 333 mV, enables simple and

detailed measurements in supply networks. With four RJ45

connections that can each connect three current and/or voltage

transformers, the EL3475-0200 is multi-functional and the ideal

solution for keeping installation simple in demanding applications.

In combination with the SCL6xxx pluggable low power split-core

transformers, the EL3475-0200 enables configuration-free

commissioning, as the current transformer ratios are set

automatically between the transformer and terminal during

start-up thanks to the electronic nameplate.

With a single voltage transformer in the system, several EL3475

-0200 EtherCAT Terminals can work together as a distributed

power measurement system and perform any number of power

measurements without any loss in performance.

The EL3475-0200 also enables instantaneous value traces to

be recorded in order to retrospectively analyze any deviation

from standard values.

Beckhoff EL3453-0090 EtherCAT Terminal

The EL3453-0090 offers the “ExtendedRange” feature enabling the use

of the full technical measuring range, which equals 130% of the specified

nominal measuring range.

In addition, the EL3453-0090 comes with the option of transmitting the

times of the last voltage and current zero crossing to the controller via

XFC technology. This can be used, for example, to carry out switching

operations to suit the application.

With the aid of the TwinSAFE SC technology (TwinSAFE Single Channel)

it is possible to make use of standard signals for safety tasks in any network

or fieldbus. To do this, EtherCAT I/Os from the areas of analog input, position

measurement or communication (4… 20 mA, incremental encoder, IO-Link,

etc.) are extended by the TwinSAFE SC function. The properties typical for

the signals and the standard functions of the I/O components are retained.

TwinSAFE SC I/Os differ optically from standard I/Os by a yellow stripe on

the front of the housing.

The TwinSAFE SC technology enables communication via a TwinSAFE protocol.

These connections can be distinguished from the usual secure communication

via Safety over EtherCAT.

Beckhoff EL3475 | EtherCAT Terminal, 12-channel analog input, 4-port

The EL3475 is a 12-channel analog input that, with a 24-bit resolution

and an input voltage of 333 mV, enables simple and detailed

measurements in supply networks. With four RJ45 connections that

can each connect three current and/or voltage transformers, the EL3475

is multi-functional and the ideal solution for keeping installation simple

in demanding applications.

In combination with the SCL6xxx pluggable low power split-core

transformers, the EL3475 enables configuration-free commissioning,

as the current transformer ratios are set automatically between the

transformer and terminal during start-up thanks to the electronic

nameplate.

With a single voltage transformer in the system, several EL3475

EtherCAT Terminals can work together as a distributed power 

measurement system and perform any number of power measurements

without any loss in performance.

Beckhoff EL3453-0120 | EtherCAT Terminal, 3-channel analog input

The EL3453-0120 EtherCAT power measurement terminal has voltage

inputs for up to 130 V AC for connecting voltage transducers, enabling

the monitoring of medium-voltage systems, for example.

The four current inputs are electrically isolated so that the terminal can

be used in all common grounded current transformer configurations

such as 2- or 3-transformer configurations with star or delta connection

incl. neutral conductor current measurement. The EL3453-0120 can be

used for simple grid analysis up to the 63rd harmonics analysis.

Alternatively, all readings can be combined in a power quality factor for

simplified diagnostics. Like all measured terminal data, the harmonic

content can be read via the process data. The EL3453-0120 offers the

“ExtendedRange” feature enabling the use of the full technical measuring

range, which equals 130% of the specified nominal measuring range.

In addition, the EL3453-0120 comes with the option of transmitting the

times of the last voltage and current zero crossing to the controller via

XFC technology. This can be used, for example, to carry out switching

operations to suit the application.

The individual Beckhoff factory calibration certificate can be downloaded

via Beckhoff Service.

Beckhoff EL3453-0100 | EtherCAT Terminal, 3-channel analog input

The EL3453-0100 EtherCAT power measurement terminal has voltage

inputs for up to 130 V AC for connecting voltage transducers, enabling

the monitoring of medium-voltage systems, for example.

The four current inputs are electrically isolated so that the terminal

can be used in all common grounded current transformer configurations

such as 2- or 3-transformer configurations with star or delta connection

incl. neutral conductor current measurement. The EL3453-0100 can be

used for simple grid analysis up to the 63rd harmonics analysis.

Alternatively, all readings can be combined in a power quality factor

for simplified diagnostics. Like all measured terminal data, the harmonic

content can be read via the process data. The EL3453-0100 offers the

“ExtendedRange” feature enabling the use of the full technical measuring

range, which equals 130% of the specified nominal measuring range.

In addition, the EL3453-0100 comes with the option of transmitting the

times of the last voltage and current zero crossing to thecontroller via

XFC technology. This can be used, for example, to carry out switching

operations to suit the application.

Beckhoff EL3453-0090 | EtherCAT Terminal, 3-channel analog input

The EL3453-0090 EtherCAT power measurement terminal has voltage

inputs for direct monitoring of high-capacity generators up to max.

690 V AC, as is common in the wind industry, for example.

No upstream voltage transformer is required. The four current inputs

are electrically isolated so that the terminal can be used in all common

grounded current transformer configurations such as 2- or 3-transformer

configurations with star or delta connection incl. neutral conductor

current measurement.

The EL3453-0090 can be used for simple grid analysis up to the 63rd

harmonics analysis. Alternatively, all readings can be combined in a

power quality factor for simplified diagnostics.

Like all measured terminal data, the harmonic content can be read via

the process data.

The EL3453-0090 offers the “ExtendedRange” feature enabling the use

of the full technical measuring range, which equals 130% of the specified

nominal measuring range.

In addition, the EL3453-0090 comes with the option of transmitting the

times of the last voltage and current zero crossing to the controller via

XFC technology. This can be used, for example, to carry out switching

operations to suit the application.

Beckhoff EL3453-0030 | EtherCAT Terminal, 3-channel analog input

The EL3453 EtherCAT power measurement terminal has voltage

inputs for direct monitoring of high-capacity generators up to max.

690 V AC, as is common in the wind industry, for example.

No upstream voltage transformer is required. The four current

inputs are electrically isolated so that the terminal can be used

in all common grounded current transformer configurations such

as 2- or 3-transformer configurations with star or delta connection

incl. neutral conductor current measurement.

The EL3453 can be used for simple grid analysis up to the 63rd

harmonics analysis. Alternatively, all readings can be combined

in a power quality factor for simplified diagnostics.

Like all measured terminal data, the harmonic content can be read

via the process data. The EL3453 offers the “ExtendedRange”

feature enabling the use of the full technical measuring range,

which equals 130% of the specified nominal measuring range.

In addition, the EL3453 comes with the option of transmitting

the times of the last voltage and current zero crossing to the

controller via XFC technology. This can be used, for example,

to carry out switching operations to suit the application.

The individual calibration certificate for each device, in accordance

with ISO 17025 or DAkkS, depending on the device variant, can

be downloaded here. These calibration certificates are issued for

Beckhoff by an accredited service provider. Recalibration on request.

Beckhoff EL3453-0020 | EtherCAT Terminal, 3-channel analog input, power measurement

The EL3453-0020 EtherCAT power measurement terminal has voltage

inputs for direct monitoring of high-capacity generators up to max.

690 V AC, as is common in the wind industry, for example.

No upstream voltage transformer is required. The four current inputs

are electrically isolated so that the terminal can be used in all common

grounded current transformer configurations such as 2- or 3-transformer

configurations with star or delta connection incl.

neutral conductor current measurement. The EL3453-0020 can be

used for simple grid analysis up to the 63rd harmonics analysis.

Alternatively, all readings can be combined in a power quality factor

for simplified diagnostics.

Like all measured terminal data, the harmonic content can be read

via the process data.

The EL3453-0020 offers the “ExtendedRange” feature enabling the

use of the full technical measuring range, which equals 130% of

the specified nominal measuring range.

In addition, the EL3453-0020 comes with the option of transmitting

the times of the last voltage and current zero crossing to the 

controller via XFC technology. This can be used, for example, to carry

out switching operations to suit the application.

The individual Beckhoff factory calibration certificate can be downloaded

via Beckhoff Service.

Search for products

Back to Top
Product has been added to your cart