The measuring ranges generally reach accuracy class 0.01%. For further

information please refer to the documentation. Through the feature

“ExtendedRange” the user has the full technical measuring range available,

up to 107% of the specified nominal measuring range, depending on the

measuring range. This feature can be disabled, in order to ensure

compatibility with the “LegacyRange” of the EL30xx/EL31xx series.

To suppress aliasing effects, the input channel features two configurable

numeric software filters up to 39th order FIR/6th order IIR.

The filters can be preselected or freely described, so that a band stop or

a band pass can be realized. The measurement at the differential input

channel is digitized with a resolution of 24 bit and 10 ksps and is

transmitted to the higher-level automation device electrically isolated and

optionally with oversampling. The data rate can be internally reduced,

in which case the filters have to be adjusted accordingly.

Non-linear characteristic sensor curves can be corrected flexibly through

an integrated sampling points table. Simple mathematical operations are

also possible.