Connect the LDT to

Module Inputs

We assume that you will use one of the following types of LDT:

• Temposonics II: RPM TTSRxxxxxxR, or

DPM TTSRxxxxxxDExxx

• Balluff: BTL-2-L2, or BTL-2-M2

• Santest: GYRP, or GYRG

• Gemco Quick-Stick II: 951VP, or 951 RS

We illustrate typical connections between the 1746-QV module and

these types of LDTs. (There are other suppliers with compatible LDTs.)

You have a choice of three configurations to match your hydraulics:

• proportional amplifier with ramp and proportional valve

• servo amplifier with ramp and variable-volume pump

• Allen-Bradley 1305 Drive and hydraulic pump

You may use either of the following output voltage ranges:

• 0-10V dc for the Allen-Bradley 1305 Drive or variable-volume pump

• –10 to +10V dc for the proportional amplifier and proportional valve