Working principle
During fired operation, heat from fuel combustion is transferred
to the furnace shell, mainly through radiation. Flue gases leaving
the furnace enter vertical uptakes where the heat is transferred
to helix tubes, mainly through convection. If the boiler is config
ured as a hybrid, the electric heater provides an alternative
heat source.
Heat transferred through the furnace shell or the helix tube walls
evaporates the adjacent saturated water on the boiler’s water
side. This causes steam bubbles to form. Because the steam
bubbles have a much lower specific density than the water, they
rise rapidly into the steam space, where the water and steam
are separated.
Maintenance
The Aalborg OS-TCi is effectively self-cleaning thanks to its
TCi (Turbo Clean, intelligent) technology, which keeps the boiler
running efficiently and prolongs its service life. The TCI cleaning
process is fully automatic.